Weekly archive
Week of November 2, 2026
The FDA cleared 57 510(k)s, granted 1 De Novo request and approved no original PMAs. 15 device recalls were posted, 2 of them Class I. Every 510(k), De Novo and PMA decision dated November 2 to 8, 2026, and every device recall the FDA posted those days.
Week beforeWeek afterRSS feedThis week as lead lists
- 510(k) clearances
- 57median review 134 days
- De Novo grants
- 1
- Original PMA approvals
- 0plus 30 supplements
- Recalls posted
- 1544 products, 2 Class I
Recalls posted
Device recalls the FDA posted November 2 to 8, 2026, Class I first. Class I is the most serious: a reasonable chance the product causes serious harm or death. The class comes from the FDA’s weekly enforcement report, so the newest recalls can show “Class pending” for a few days.
| Recall and class | Firm and reason | Product code |
|---|---|---|
| Z-0212-2027Class I | Cardinal Health 200, LLCKits contain infusion sets which were recalled for performance issues. | LRO LRP LRS11 products |
| Z-0287-2027Class I | Edwards Lifesciences, LLCDue to a manufacturing issue which may result in cardiovascular balloon rupturing. | NPU1 product |
| Z-0358-2027Class II | AVID Medical, Inc.Shelf label of kit is mislabeled as "Extremity" instead of "Arthroscopy Pack." | LRO1 product |
| Z-0359-2027Class II | Luminex CorporationInstructions for Use updated to include explicit guidance that repeat testing is recommended whenever a positive family-level only result is obtained. Issue may contribute to incorrect or delayed diagnosis of bloodstrea… | NSU1 product |
| Z-0326-2027Class II | GE Medical Systems, LLCGE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisition configuration of the anode track/filter combination is dif… | MUE OTE3 products |
| Z-0357-2027Class II | INTELERAD MEDICAL SYSTEMS INCORPORATEDA cybersecurity vulnerability has been identified in the software that could allow a malicious user to take over an administrator session, delete or modify image or study data, or lock legitimate users out of the system… | LLZ1 product |
| Z-0331-2027Class II | AVID Medical, Inc.Potential for open seals on header bags, compromising sterility. | LRO1 product |
| Z-0332-2027Class II | Baxter Healthcare CorporationThe main lift may unexpectedly drop from its set position to its lowest position during use. The tabletop may not be able to be raised again after the drop occurs. An uncontrolled drop of the surgical table may result i… | GDC2 products |
| Z-0334-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | GAM GAP GAW13 products |
| Z-0347-2027Class II | SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISIONThe mounting bolts securing the C-arm drive unit of the X-ray system may not be torqued to specification, potentially compromising structural stability and safe operation. | OWB1 product |
| Z-0348-2027Class II | restor3d Inc.(Retroactively reported) Pairing of shoulder implant stem sizes 1 and 2 with the largest glenosphere diameter (40 mm) creates an excessive mechanical loading configuration in which certain polyethylene components lack a… | PHX1 product |
| Z-0349-2027Class II | Cochlear LimitedDue to a manufacturing deviation of incomplete electrode welds of cochlear implants and resulting in one or more open circuits | MCM1 product |
| Z-0350-2027Class II | Baxter Healthcare CorporationThere is an issue with the main lift mechanism. The main lift may unexpectedly drop from its set position to its lowest position during use. In these cases, the tabletop could not be raised again after the drop occurred… | GDC5 products |
| Z-0355-2027Class II | Remel, IncAffected lot did not meet specifications. Product may report false susceptibility to antifungal agents, specifically within the Azole family. | NGZ1 product |
| Z-0356-2027Class II | CORIN MEDICAL, LTD.Potential malfunction of the Modular Handles where the locking mechanism may fail. Any mating instruments already engaged to the handle will not be able to be disengaged, and the handle will be unable to fitted securely… | JWH1 product |
Original PMA approvals
Original premarket approvals for Class III devices. The FDA also decided 30 PMA supplements this week, which change devices already approved.
No original PMAs were approved this week.
510(k) clearances
57 510(k) clearances by review panel. The median took 134 calendar days from receipt to decision; the fastest, K263749, 21 days; the longest, K252865, 423 days.
Calendar days include the time a submission waits on the company, so they run longer than the FDA’s 90-day review goal. How to search the 510(k) database
- Cardiovascular12
- General, Plastic Surgery8
- Orthopedic7
- Radiology7
- Neurology6
- Dental5
- Microbiology5
- General Hospital3
- Anesthesiology1
- Clinical Chemistry1
- Immunology1
- Physical Medicine1
Every clearance
| Number | Device and applicant | Product code | Decision and review time |
|---|---|---|---|
| K260990 | Model 7000 SpirotracVitalograph , Ltd. | BZGAnesthesiology | Nov 4, 2026224 days |
| K260383 | iCOR BeatiCOR Medical, LLC | MWJCardiovascular | Nov 2, 2026270 days |
| K260436 | ECG Buddy-LVD (EB-LVD-01)ARPI, Inc. | QYECardiovascular | Nov 6, 2026268 days |
| K260600 | Neuroguard IEP Embolic Protection SystemContego Medical, Inc. | NTECardiovascular | Nov 4, 2026253 days |
| K260608 | TagBand Manual; TagBand AutoUK Innovations, GP, Ltd. | DXCCardiovascular | Nov 6, 2026255 days |
| K261307 | 12SL PrecisionGe Medical Systems Information Technologies, Inc. | MHXCardiovascular | Nov 3, 2026196 days |
| K261376 | Progreat Lambda 2.1FrTerumo Clinical Supply Co., Ltd. | KRACardiovascular | Nov 5, 2026192 days |
| K261449 | NeuroSheathPerfuze, Ltd. | QJPCardiovascular | Nov 5, 2026188 days |
| K261870 | ANNE LimbSibel Health | DQACardiovascular | Nov 5, 2026154 days |
| K262171 | Merge Hemo (Model RCSV2 (v11.3))Merge Healthcare Incorporated | DQKCardiovascular | Nov 5, 2026132 days |
| K262590 | Parafleet NC 014 PTA Balloon Dilatation Catheter; Parafleet NC 018 PTA Balloon Dilatation CatheterBrosmed Medical Co., Ltd. | LITCardiovascular | Nov 2, 202698 days |
| K262858 | OxySight for MolecuLightDX+MolecuLight, Inc. | MUDCardiovascular | Nov 5, 202684 days |
| K263678 | Option™ELITE Vena Cava Filter System; Option™ELITE Vena Cava Filter 100cm SystemArgon Medical Devices, Inc. | DTKCardiovascular | Nov 5, 202629 days |
| K260674 | Atellica IM Vitamin D Total II (VitDII)Siemens Healthcare Diagnostics, Inc. | MRGClinical Chemistry | Nov 6, 2026249 days |
| K260132 | Jason membraneBotiss Biomaterials GmbH | NPLDental | Nov 8, 2026296 days |
| K260464 | Dental Electric Motor System (iM2X)DTL Dental Equipment Manufacture Co., Ltd. | EBWDental | Nov 6, 2026267 days |
| K260483 | FormaAid Collagen MembraneMaxigen Biotech, Inc. | NPLDental | Nov 4, 2026264 days |
| K262790 | DentalMonitoringDental Monitoring Sas | SBCDental | Nov 4, 202690 days |
| K263004 | Ezi-CrownMEDICLUS | EBGDental | Nov 3, 202667 days |
| K260478 | CleanBreak™Icu Medical, Inc. | QOIGeneral Hospital | Nov 6, 2026266 days |
| K260631 | Medican Alpha, Medican, Mediflon, Mediflon Quick, Medican Alpha Safety, Medican Safety, Mediflon Safety, Mediflon Safety Quick, Medican Alpha Safety Pro, Medican Safety Pro, Mediflon Safety Pro, Neocan, Enfancie, Neocan safety, Enfancie SafetyGlobal Medikit Limited | FOZGeneral Hospital | Nov 5, 2026252 days |
| K260730 | Mix2Vial® transfer deviceWest Pharma. Services IL, Ltd. | LHIGeneral Hospital | Nov 5, 2026245 days |
| K261918 | IPL Hair Removal Device (IN-HR001, IN-HR005L)ShenZhen Qiyue Trading Co., Ltd. | OHTGeneral, Plastic Surgery | Nov 3, 2026147 days |
| K262232 | Wound VOX NPWT System (V1-01-01); Wound VOX 300ml Collection Canister & Supply Tubing (CC-00-03); Wound VOX Y-Connector (YK-01-13); Wound VOX Dressing Kit Small (DK-01-01); Wound VOX Dressing Kit Medium (DK-01-02); Wound VOX Dressing Kit Large (DK-01-03); Wound VOX Adhesive Drape (DK-01-04); Wound VOX Foam Dressing (DK-01-05); Wound VOX Suction Bell Assembly (DK-01-06); Wound VOX Wound Contact Layer (10cmx8cm) (DK-01-07); Wound VOX Wound Contact Layer (25cmx17cm) (DK-01-14)Bechtel Medical, Inc. | OMPGeneral, Plastic Surgery | Nov 6, 2026129 days |
| K262500 | Stryker Steri-Shield 8 Non-Sterile Hoods and TogasStryker Instruments | QPCGeneral, Plastic Surgery | Nov 4, 2026107 days |
| K262781 | LED Light Therapy Mask (4D Glow Mask FM19-0K, 4D Glow Mask FM19-1K, 4D Glow Mask FM19-2K, 4D Glow Mask FM19-VK, 4D Glow Mask FM35-0K, 4D Glow Mask FM35-1K, 4D Glow Mask FM35-2K, 4D Glow Mask FM35-VK)Guangdong Newdermo Biotech Co., Ltd. | OHSGeneral, Plastic Surgery | Nov 4, 202690 days |
| K262886 | Single Use Optical FiberQuanta System Spa | GEXGeneral, Plastic Surgery | Nov 5, 202680 days |
| K263567 | PICO 7 Single Use Negative Pressure Wound Therapy System; PICO 14 Single Use Negative Pressure Wound Therapy System; PICO Fluid Management PacksSmith and Nephew Medical Limited | QFCGeneral, Plastic Surgery | Nov 6, 202637 days |
| K263664 | Pre-B Seal Lung Biopsy Plug System (Model FG0004)Selio Medical Limited | OMTGeneral, Plastic Surgery | Nov 3, 202629 days |
| K263682 | BioChargeNanofiber Solutions, LLC | OWWGeneral, Plastic Surgery | Nov 5, 202629 days |
| K260400 | IMMULITE 2000 nAra h 1; IMMULITE 2000 nAra h 3; IMMULITE 2000 nAra h 6Siemens Healthcare Diagnostics Products, Ltd. | DHBImmunology | Nov 2, 2026269 days |
| K262172 | BIOFIRE FILMARRAY Gastrointestinal 1.1 (GI1.1) Panel; BIOFIRE FILMARRAY Gastrointestinal 1.1 (GI1.1) Panel MidBiofire Diagnostics, LLC | PCHMicrobiology | Nov 6, 2026133 days |
| K262683 | VITEK PRObioMérieux, Inc. | LONMicrobiology | Nov 3, 202695 days |
| K262789 | SimplicityDx Panel FluA/FluB/RSVMolecular Designs | OCCMicrobiology | Nov 4, 202690 days |
| K262807 | VITEK 2 AST-Gram Negative Polymyxin B (<= 0.25 – >=16µg/mL); VITEK 2 AST-Gram Negative Imipenem (<= 0.25 – >=16µg/mL); VITEK 2 AST-Gram Negative Ceftazidime Avibactam (<= 0.125 – >=16µg/mL)BIOMERIEUX, Inc. | LONMicrobiology | Nov 4, 202689 days |
| K262842 | BioFire Warrior Panel Control KitBioFire Defense, LLC | PMNMicrobiology | Nov 4, 202684 days |
| K254222 | PRIMARY (CP.A.B.C.D, UP.A.B.C.D); PRIMARY-Z (PS.A.B.C.D, PSS.A.B.C.D, PSD.A.B.C.D); PRIMARY-O (OR.A.B.C.D, ORS.A.B.C.D, ORD.A.B.C.D)Cusmedi Co., Ltd. | GXNNeurology | Nov 6, 2026312 days |
| K260431 | Dura-Guard Dural Repair PatchSynovis Life Technologies, Inc. (Baxter International Inc.) | GXQNeurology | Nov 5, 2026282 days |
| K261157 | Stereotactic Ultralight System SUSyinomed Medizintechnik GmbH | HAWNeurology | Nov 6, 2026212 days |
| K262716 | StealthStation™ S8 Cranial v2.3.0Medtronic Navigation | HAWNeurology | Nov 6, 202698 days |
| K262755 | Wave Electrode; Remote Wave ElectrodeBionit Labs Srl | GXYNeurology | Nov 6, 202695 days |
| K263666 | BioWave BioWrapsBiowave Corporation | GXYNeurology | Nov 5, 202631 days |
| K252865 | 4CIS BLUE DOLPHIN CAGE SYSTEMSolco Biomedical Company India Private Limited | MAXOrthopedic | Nov 6, 2026423 days |
| K260417 | Easytech Reversed Shoulder SystemFX Shoulder Solutions, Inc. | SJWOrthopedic | Nov 5, 2026269 days |
| K260496 | PearlBone™ Putty 1600Marine Biomedical | MQVOrthopedic | Nov 2, 2026262 days |
| K262286 | ELEOS™ with NanoCept® Technology Limb Salvage SystemOnkos Surgical, Inc. | QZZOrthopedic | Nov 5, 2026122 days |
| K262939 | HERO Sternal Closure SystemHero Orthopedics, LLC | HRSOrthopedic | Nov 2, 202673 days |
| K263241 | DuoCore Non-Compressive IM NailGM Dos Reis Industria e Comercio Ltda. | HWCOrthopedic | Nov 2, 202647 days |
| K263244 | SF Push-in AnchorSurgical Fusion Technologies GmbH | MAIOrthopedic | Nov 5, 202650 days |
| K262329 | Electric Wheelchair (MK100W(6012A), MK100W(6016A), MK100W(9005), MK100W(9006))MAIKANG MEDICAL EQUIPMENT (HEBEI) CO., Ltd. | ITIPhysical Medicine | Nov 6, 2026120 days |
| K260372 | Clever OneEwoosoft Co., Ltd. | QIHRadiology | Nov 4, 2026272 days |
| K260454 | LiLi DICOM Viewer (LiLi )Elevate Imaging, Inc. | LLZRadiology | Nov 4, 2026266 days |
| K262011 | MAGNETOM Free.XLSiemens Healthineers AG | LNHRadiology | Nov 5, 2026143 days |
| K262028 | EUROPA85, EUROPA85L, and EUROPA90 Portable X-ray Systems (EUROPA85, EUROPA85L, EUROPA90)Aspen Imaging Healthcare, Inc. | IZLRadiology | Nov 6, 2026143 days |
| K262132 | 3D Anatomical ModelThe Jacobs Institute | LLZRadiology | Nov 5, 2026134 days |
| K262667 | PeekMed® webPeek Health, S.A. | QIHRadiology | Nov 4, 202697 days |
| K263749 | CadAI-B DxBeamWorks, Inc. | QDQRadiology | Nov 6, 202621 days |
Only see the weeks that matter to you
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and every day it checks openFDA and tells you about new clearances, recalls and MAUDE reports for them. It also puts all of this beside the FDA’s own record pages.
Only your product codes, every Monday
One short email after each openFDA update with just the decisions and recalls in up to three product codes you choose. Free.
Earlier weeks
Each week keeps its own page.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Decisions arrive in weekly updates; check the FDA record before you rely on a figure.
- device/510k · search decision_date:[20261102 TO 20261108]Retrieved Nov 29, 2026, 8:00 AM UTC. FDA data updated Nov 16, 2026.
- device/pma · search decision_date:[20261102 TO 20261108]Retrieved Nov 29, 2026, 8:00 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search event_date_posted:[20261102 TO 20261108]Retrieved Nov 29, 2026, 8:00 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0358-2027" "Z-0359-2027" "Z-0326-2027" "Z-0327-2027" "Z-0328-2027" "Z-0357-2027" "Z-0331-2027" "Z-0332-2027" "Z-0333-2027" "Z-0334-2027" "Z-0335-2027" "Z-0336-2027" "Z-0337-2027" "Z-0338-2027" "Z-0339-2027" "Z-0340-2027" "Z-0341-2027" "Z-0342-2027" "Z-0343-2027" "Z-0344-2027" "Z-0345-2027" "Z-0346-2027" "Z-0347-2027" "Z-0348-2027" "Z-0349-2027" "Z-0350-2027" "Z-0351-2027" "Z-0352-2027" "Z-0353-2027" "Z-0354-2027" "Z-0355-2027" "Z-0356-2027" "Z-0212-2027" "Z-0213-2027" "Z-0214-2027" "Z-0215-2027" "Z-0216-2027" "Z-0217-2027" "Z-0218-2027" "Z-0219-2027" "Z-0220-2027" "Z-0221-2027" "Z-0222-2027" "Z-0287-2027")Retrieved Nov 29, 2026, 8:00 AM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil