FDA product code
HRS: Plate, Fixation, Bone (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 888.3030
- Review panel
- Orthopedic
- Premarket route
- 510(k)
- Implant
- Yes
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 1,33661 in the last 12 months
- Median review time
- 83 daysthe latest 25 decisions
- Recall records
- 28820 in the last 12 months
- Adverse event reports
- 1,943last 12 months, 1 death
510(k) and De Novo decisions
Decisions for product code HRS per year, by decision date, 1,336 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 57 |
| 2018 | 40 |
| 2019 | 46 |
| 2020 | 48 |
| 2021 | 40 |
| 2022 | 47 |
| 2023 | 40 |
| 2024 | 54 |
| 2025 | 54 |
| 2026 (so far) | 56 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262903 | VariAx 2 Ulna ShorteningStryker GmbH | Nov 13, 202687 days |
| K262939 | HERO Sternal Closure SystemHero Orthopedics, LLC | Nov 2, 202673 days |
| K263602 | Arthrex Plates, Screws and Pins, and WashersArthrex, Inc. | Oct 29, 202629 days |
| K261135 | Trochlear Salvage Plating SystemSkeletal Dynamics, Inc. | Oct 26, 2026202 days |
| K263407 | Tempo Plating SystemPace Surgical | Oct 23, 202628 days |
| K262779 | ANTHEM™ Fracture SystemGlobus Medical, Inc. | Oct 23, 202679 days |
| K263269 | Park's Pectus SystemTdm Co., Ltd. | Oct 15, 202627 days |
| K261611 | TDM Large Bone Plate and Screw SystemTdm Co., Ltd. | Oct 2, 2026140 days |
| K262649 | Alians ForearmNewclip Technics | Sep 28, 202660 days |
| K261892 | ProRib Fixation SystemCosta Surgical, Inc. | Sep 23, 2026110 days |
Recalls
Recall records for product code HRS per year, by the date the recall began. Each recalled product is one record; these 288 records belong to 129 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 8 |
| 2018 | 32 |
| 2019 | 27 |
| 2020 | 30 |
| 2021 | 12 |
| 2022 | 4 |
| 2023 | 8 |
| 2024 | 2 |
| 2025 | 21 |
| 2026 (so far) | 18 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0318-2027Class II | Smith & Nephew, Inc.Incorrect labeling; 3.5MM Partial Articular Lateral Proximal Tibia Plate 6 hole Left 91MM implant labeled and lasered etched as as 3.5MM Lateral Proximal Tibia… | Sep 6, 2026 |
| Z-3334-2026Class II | Wright Medical Technology, Inc.Screws, intended for use with polyaxial compression plating system intended for foot osteotomies, was manufactured with missing threads on the screwheads, whic… | Aug 18, 2026 |
| Z-2532-2026Class II | Acumed LLCDue to manufacturing error, hexalobe screws used with wrist fixation system may break during use. | May 28, 2026 |
| Z-1592-2026Class II | I.T.S. GmbHUpdated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for… | Jan 23, 2026 |
| Z-1593-2026Class II | I.T.S. GmbHUpdated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for… | Jan 23, 2026 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code HRS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 2,220 |
| 2018 | 2,663 |
| 2019 | 3,358 |
| 2020 | 2,790 |
| 2021 | 2,442 |
| 2022 | 1,700 |
| 2023 | 2,049 |
| 2024 | 1,849 |
| 2025 | 2,334 |
| 2026 (so far) | 1,695 |
Last 12 months by event type
- Deaths1
- Injuries1,490
- Malfunctions451
- Other or not stated1
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem869
- Fracture216
- Break171
- Patient Device Interaction Problem140
- Device-Device Incompatibility112
- Migration80
In plain English: what the newest reports describe Written by AI
A bone plate broke. The reports give no further details about how it broke or what happened to the patient, and the manufacturer has not provided more information.
Report: 0009613350-2026-00526
A patient had a femoral (thigh bone) fracture about 1 year and 7 months after a plate was implanted, and needed revision fixation, which is a second surgery to repair the fixation. No further information is available.
Report: 0009613350-2026-00529
During surgery on a humerus (upper arm bone) fracture using two elbow plates, several locking screws failed to lock into the plate, meaning they did not fasten securely to it.
Report: 8030965-2026-10915
A surgical driver shaft damaged the screw head. The screw drive did not engage reliably, so the screw could unscrew and become damaged during insertion and tightening. The surgery was finished with a new device of the same part number, and no harm was reported.
Report: 1220246-2026-05446
When surgical sets came back to the office, staff found that specified items were broken and missing their screw parts. No patient harm or surgical delay was reported.
Report: 8030965-2026-11055
Written by AI from the narratives of the 8 newest reports that have one, received Oct 27, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 86,512in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 4,974registered establishments that list this product code
Other codes under 21 CFR 888.3030
Product codes classified under the same regulation.
Watch HRS in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get HRS every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HRS. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:HRSRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HRSRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HRS · count decision_dateRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:HRSRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HRS · count event_date_initiatedRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HRS · count res_event_numberRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0318-2027" "Z-3334-2026" "Z-2532-2026" "Z-1592-2026" "Z-1593-2026")Retrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HRS AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HRS AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HRS AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:HRSRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:HRSRetrieved Nov 29, 2026, 6:36 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:888.3030Retrieved Nov 28, 2026, 5:24 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil