FDA product code
GAW: Suture, Nonabsorbable, Synthetic, Polypropylene (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 878.5010
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k)
- Implant
- Yes
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- 510(k) and De Novo decisions
- 851 in the last 12 months
- Median review time
- 135 daysthe latest 25 decisions
- Recall records
- 337 in the last 12 months
- Adverse event reports
- 2,704last 12 months, 7 deaths
510(k) and De Novo decisions
Decisions for product code GAW per year, by decision date, 85 since 1990. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 3 |
| 2018 | 3 |
| 2019 | 1 |
| 2020 | 2 |
| 2021 | 0 |
| 2022 | 2 |
| 2023 | 1 |
| 2024 | 1 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K253572 | STRATAFIX™ Spiral PRONOVA™ Unidirectional Knotless Tissue Control Device STRATAFIX™ Spiral PRONOVA™ Bidirectional Knotless Tissue Control DeviceETHICON, Inc. | Mar 27, 2026130 days |
| K233355 | Cypris eXact Suturing SystemCypris Medical | Jan 12, 2024105 days |
| K230746 | Non absorbable Surgical Polypropylene SutureShandong Haidike Medical Products Co., Ltd. | Sep 14, 2023181 days |
| K221280 | VessealLydus Medical , Ltd. | Dec 9, 2022220 days |
| K211178 | DURAMESH Mesh SutureMsi | Sep 2, 2022500 days |
| K192953 | APTOS Threads – Polypropylene Surgical SuturesAptos, LLC | Aug 27, 2020311 days |
| K193530 | Deklene MAXXTeleflex Medical | Mar 19, 202090 days |
| K191299 | Silhouette Featherlift / Silhouette LiftSilhouette Lift, Inc. | Jun 14, 201931 days |
| K173747 | REXLENESm Eng Co., Ltd. | Dec 21, 2018378 days |
| K180321 | Aesculap Optilene Nonabsorbable SutureAesculap, Inc. | Mar 7, 201830 days |
Recalls
Recall records for product code GAW per year, by the date the recall began. Each recalled product is one record; these 33 records belong to 7 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 19 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 2 |
| 2023 | 0 |
| 2024 | 3 |
| 2025 | 0 |
| 2026 (so far) | 7 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0334-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | Sep 17, 2026 |
| Z-0338-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | Sep 17, 2026 |
| Z-0341-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | Sep 17, 2026 |
| Z-0342-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | Sep 17, 2026 |
| Z-0346-2027Class II | Henry Schein Inc.Products lack 510(k) clearance. | Sep 17, 2026 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code GAW. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 413 |
| 2018 | 685 |
| 2019 | 1,803 |
| 2020 | 1,493 |
| 2021 | 1,652 |
| 2022 | 1,563 |
| 2023 | 1,811 |
| 2024 | 2,348 |
| 2025 | 2,583 |
| 2026 (so far) | 2,378 |
Last 12 months by event type
- Deaths7
- Injuries383
- Malfunctions2,312
- Other or not stated2
Most reported device problems, last 12 months
- Break1,325
- Material Separation667
- Adverse Event Without Identified Device or Use Problem224
- Detachment of Device or Device Component181
- Material Split, Cut or Torn157
- Material Frayed98
In plain English: what the newest reports describe Written by AI
The suture thread broke, split or frayed while surgeons were sewing tissue, tying knots or closing the aorta, and they switched to another suture to finish. In one report this caused bleeding from the aorta and about a 30-minute longer operation.
7 reports: 9612501-2026-02984, 2210968-2026-10932, 2210968-2026-10916, 2210968-2026-10729, 9612501-2026-02908, 3003639970-2026-00954, 2210968-2026-10943
The needle came apart from the suture thread during use, in one report while the needle was inside the aorta, the main artery from the heart. In that report the needle was retrieved and a new suture was placed, and in another report the thread fractured from the needle.
3 reports: 3003639970-2026-01004, 2210968-2026-10782, 2210968-2026-10827
Some sutures had problems with their packaging or contents: one could not be removed from its package without great force and its thread was frayed, another came out of its package with a knot in it, and a third package had foreign matter in it.
3 reports: 3003639970-2026-01021, 51203435, 2210968-2026-10890
A needle broke, and in one report the broken needle fell into the patient's cardiovascular system and a second surgery was needed to remove it, adding about 30 minutes. In another report a needle tail broke and was replaced during surgery.
2 reports: 2210968-2026-10707, 2210968-2026-10882
A needle was lost or lodged in the body and could not be found or removed. In one report a needle lodged in the pelvic area and a vaginal laparoscopy failed to retrieve it, and in another the location of a lost needle was unknown.
2 reports: 2210968-2026-10778, 3004365956-2026-00027
Written by AI from the narratives of the 18 newest reports that have one, received Oct 20, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 7,895in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 226registered establishments that list this product code
Other codes under 21 CFR 878.5010
Product codes classified under the same regulation.
Watch GAW in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get GAW every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GAW. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:GAWRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GAWRetrieved Nov 29, 2026, 4:15 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GAW · count decision_dateRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:GAWRetrieved Nov 29, 2026, 4:15 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GAW · count event_date_initiatedRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GAW · count res_event_numberRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0334-2027" "Z-0338-2027" "Z-0341-2027" "Z-0342-2027" "Z-0346-2027")Retrieved Nov 29, 2026, 4:15 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GAW AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:15 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GAW AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:15 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GAW AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 1:17 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:GAWRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:GAWRetrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.5010Retrieved Nov 28, 2026, 7:03 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil