MUE: Full Field Digital, System, X-Ray, Mammographic (FDA product code)

Follow MUE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 892.1715
Review panel
Radiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
564 in the last 12 months
Median review time
209 daysthe latest 25 decisions
Recall records
433 in the last 12 months
Adverse event reports
66last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code MUE per year, by decision date, 56 since 2011. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20178
20182
20192
20204
20214
20223
20231
20241
20253
2026 (so far)4

Latest decisions

NumberDevice and applicantDecision and review time
K254090 I-View®Hologic, Inc. Sep 2, 2026257 days
K253678 MAMMOMAT B.brilliant (11372950)Siemens Medical Solutions USA, Inc. Jun 18, 2026209 days
K254092 Bellalun 2D (VDMS-1000S)Vieworks Co., Ltd. May 28, 2026160 days
K260087 Senographe Pristina; SenoBright HD; Pristina Serena; Pristina Serena BrightGE Medical Systems SCS Mar 24, 202671 days
K243420 HESTIAGenoray Co., Ltd. Jul 17, 2025255 days
K243849 2430TCA with Xmaru WRayence Co., Ltd. Mar 12, 202586 days
K241113 VIVIX-MVieworks Co., Ltd. Jan 16, 2025269 days
K233539 MAMMOMAT B.brilliantSiemens Medical Solutions USA, Inc. Mar 27, 2024145 days
K220073 RMF-2000DRTECH Corporation Jan 26, 2023381 days
K211720 Planmed Clarity 2D, Planmed Clarify SPlanmed OY Jul 18, 2022409 days

Recalls

Recall records for product code MUE per year, by the date the recall began. Each recalled product is one record; these 43 records belong to 33 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20177
20181
20193
20202
20210
20220
20231
20240
20254
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-0326-2027Class II GE Medical Systems, LLCGE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisitio… Aug 28, 2026
Z-0327-2027Class II GE Medical Systems, LLCGE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisitio… Aug 28, 2026
Z-2167-2026Class II Hologic, IncComplaints have been received of systems developing loose, missing, or broken internal bolts over time. Apr 8, 2026
Z-0875-2026Class II GE Medical Systems, LLCSome Senographe Pristina systems either have a missing or an incorrect X-Ray Warning label, which is a nonconformance to FDA Regulation 21 CFR 1020.30(j). Oct 24, 2025
Z-0877-2026Class II Siemens Medical Solutions USA, IncThere were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus instal… Oct 24, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MUE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017115
2018144
201980
202049
202125
202236
202329
202433
202540
2026 (so far)60

Last 12 months by event type

  • Deaths0
  • Injuries3
  • Malfunctions61
  • Other or not stated2

Most reported device problems, last 12 months

  1. Unintended System Motion22
  2. Unintended Movement13
  3. Break3
  4. Installation-Related Problem3
  5. Mechanics Altered3
  6. Defective Device2

In plain English: what the newest reports describe Written by AI

  • Multiple reports describe the C-arm moving when no one commanded it, including continuing to rotate after the control was released, lowering on its own, or moving past a set stop. The manufacturer linked some cases to sticking switches or a sticking rotation mechanism, and blamed high room heat and humidity in one case.

    6 reports: 3005496266-2026-00334, 3005496266-2026-00159, 3005496266-2026-00186, 3005496266-2026-00143, 3005496266-2026-00133, 3005496266-2026-00179

  • Multiple reports describe the unit shaking, vibrating, or making loud noises during movement. The problem was traced to loose bolts in the vertical travel assembly, which raises and lowers the C-arm. In one report a broken rotational gear bolt was found, and the assembly was replaced.

    5 reports: 3005496266-2026-00317, 3005496266-2026-00269, 3005496266-2026-00273, 3005496266-2026-00191, 3005496266-2026-00107

  • One report describes the gantry moving unexpectedly during a stereotactic breast biopsy while the needle was still in the patient's breast, pulling the needle out. The team stopped the machine and removed the needle, and no added physical injury was found. A marker clip was not placed, and the manufacturer found no loose bolts on inspection.

    Report: 50068059

  • One report describes a technologist's hand being injured when the C-arm's path was blocked by a gas tank during a patient exam, and the technologist tried to move the tank. The injury needed stitches. The service engineer found the tube head cover slightly bent, realigned it, and confirmed normal operation.

    Report: 3005496266-2026-00257

  • One report describes the compression paddle activating unexpectedly while the technologist was away from the controls, causing a patient to cry out and suffer bruising. Compression was released right away. The service engineer replaced the rotation switch assembly, which system logs suggested might have been accidentally activated.

    Report: 3005496266-2026-00093

Written by AI from the narratives of the 19 newest reports that have one, received May 1, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
244in the FDA’s Global Unique Device Identification Database
Establishment listings
122registered establishments that list this product code

Watch MUE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MUE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MUE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.