Product codes

FDA product code

HWC: Screw, Fixation, Bone (FDA product code)

Follow HWC: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.3040
Review panel
Orthopedic
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1,07123 in the last 12 months
Median review time
111 daysthe latest 25 decisions
Recall records
3896 in the last 12 months
Adverse event reports
3,100last 12 months, 1 death

510(k) and De Novo decisions

Decisions for product code HWC per year, by decision date, 1,071 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
201740
201820
201930
202028
202126
202226
202324
202417
202515
2026 (so far)22

Latest decisions

NumberDevice and applicantDecision and review time
K263241 DuoCore Non-Compressive IM NailGM Dos Reis Industria e Comercio Ltda. Nov 2, 202647 days
K261961 Ntegrate Threaded Nail SystemNvision Biomedical Technologies Oct 14, 2026125 days
K263116 OsteoCentric Technologies Cannulated and Soild Fasteners with NutsOsteoCentric Technologies Oct 2, 202628 days
K262975 Arthrex Beaming SystemArthrex, Inc. Sep 25, 202630 days
K260995 DynaNail Helix® Fixation SystemMedShape, Inc. Sep 23, 2026181 days
K254280 F.A.S.T ScrewSteps Ortho Sep 21, 2026265 days
K261057 ActivaScrew™ Cannulated COMBioretec, Ltd. Sep 4, 2026157 days
K260106 OsteoCoil™ GT Active Compression SystemFlower Orthopedics Corporation DBA Conventus Flower Orthoped Aug 24, 2026222 days
K262344 Large Compression ScrewsTriMed, Inc. Aug 12, 202633 days
K253858 GFS - Sterile Screws and Top HatT.A.G. Medical Products Corporation, Ltd. Aug 5, 2026245 days

Recalls

Recall records for product code HWC per year, by the date the recall began. Each recalled product is one record; these 389 records belong to 136 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
201713
201822
201912
20207
20215
202213
20230
202426
20251
2026 (so far)6

Latest recalls

Recall and classFirm and reasonBegan
Z-0157-2027Class II In2bones USA, LLCDue to labeling error, bone screws specified as fully threaded, are actually partially threaded screws. Sep 9, 2026
Z-2361-2026Class II Medartis AGThe cannulation of the CCS screw is not centered. Apr 24, 2026
Z-1599-2026Class II I.T.S. GmbHUpdated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for… Jan 23, 2026
Z-1606-2026Class II I.T.S. GmbHUpdated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for… Jan 23, 2026
Z-1549-2026Class II Medartis AGMix up between specified lots of 2.5mm and 2.8mm outer diameter screws. Jan 9, 2026

Adverse event reports (MAUDE)

Medical device reports received per year that name product code HWC. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172,561
20183,662
20195,464
20204,820
20214,446
20223,934
20233,719
20243,575
20252,930
2026 (so far)2,871

Last 12 months by event type

  • Deaths1
  • Injuries1,536
  • Malfunctions1,559
  • Other or not stated4

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem784
  2. Break607
  3. Device-Device Incompatibility336
  4. Fracture294
  5. Migration231
  6. Material Deformation182

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
136,001in the FDA’s Global Unique Device Identification Database
Establishment listings
6,697registered establishments that list this product code

Watch HWC in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get HWC every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HWC. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.