Product codes

FDA product code

OTE: Digital Breast Tomosynthesis (FDA product code)

Follow OTE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
None listed
Review panel
Radiology
Premarket route
PMA
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
PMA decisions
314 original PMAs, the rest supplements
Median review time
162 daysthe latest 25 decisions
Recall records
62 in the last 12 months
Adverse event reports
254last 12 months, 0 deaths

PMA decisions

Original PMAs and supplements for product code OTE per year, by decision date, 31 since 2011. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20178
20182
20194
20202
20211
20220
20231
20243
20252
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
P140011 S009 MAMMOMAT B.brilliant with Tomosynthesis OptionSiemens Medical Solutions USA, Inc. Jul 1, 2026237 days
P080003 S011 Envision Mammography PlatformHologic, Inc. Nov 24, 202531 days
P130020 S005 Senographe Pristina 3DGE Healthcare Nov 21, 2025214 days
P140011 S008 MAMMOMAT B.brilliant with Tomosynthesis OptionSiemens Medical Solutions USA, Inc. Sep 23, 2024207 days
P080003 S009 Envision Mammography PlatformHologic, Inc. Jul 5, 2024309 days
P080003 S010 Selenia Dimensions/3DimensionsHologic, Inc. May 29, 2024162 days
P160031 S004 ASPIRE Cristalle Digital Breast Tomosynthesis (DBT) OptionFujifilm Medical Systems U.S.A, Inc. Feb 13, 202390 days
P130020 S004 Senographe Pristina 3D and SenoClaireGE Healthcare Mar 23, 2021323 days
P160031 S003 ASPIRE Cristalle Digital Breast Tomosynthesis (DBT) OptionFujifilm Medical Systems U.S.A, Inc. Sep 30, 202090 days
P140011 S007 MAMMOMAT Revelation with Tomosynthesis Option SystemSiemens Medical Solutions USA, Inc. Aug 21, 2020205 days

Recalls

Recall records for product code OTE per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 6 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20241
20251
2026 (so far)2

Latest recalls

Recall and classFirm and reasonBegan
Z-0328-2027Class II GE Medical Systems, LLCGE HealthCare has become aware of a nonconformance to certain Senographe Pristina VIA systems. Specifically, in cases of 3D+2D manual mode where the acquisitio… Aug 28, 2026
Z-2168-2026Class II Hologic, IncComplaints have been received of systems developing loose, missing, or broken internal bolts over time. Apr 8, 2026
Z-2219-2025Class II FUJIFILM Healthcare Americas CorporationDevices had an unapproved slabbing software function enabled for use. Jun 11, 2025
Z-3248-2024Class II Hologic IncIdentified an issue with Selenia Dimensions 1.12.0 and 3Dimensions 2.3.0 system software when used in combination with C-View software in which the quality of… Aug 19, 2024
Z-1144-2023Class II Hologic, Inc.C-Arm unexpected movement may cause blunt trauma should the tube arm impinge upon an individual Jan 16, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OTE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017166
201887
201980
202037
202140
202258
202359
2024130
2025142
2026 (so far)240

Last 12 months by event type

  • Deaths0
  • Injuries18
  • Malfunctions236
  • Other or not stated0

Most reported device problems, last 12 months

  1. Unintended System Motion130
  2. Unintended Movement39
  3. Mechanical Problem12
  4. Device Emits Odor10
  5. Vibration6
  6. Appropriate Device Problem Term/Code Not Available5

In plain English: what the newest reports describe Written by AI

  • Several reports describe the moving arm (C-arm or gantry) continuing to move after the operator released the control. Field engineers found causes in the switches, footswitch, drag brake or vertical drive, and replaced parts such as the switches, footswitch, drag brake or drag clutch, then tested the system.

    7 reports: 3005496266-2026-00329, 3005496266-2026-00314, 3005496266-2026-00309, 3005496266-2026-00306, 3005496266-2026-00258, 3005496266-2026-00338, 3005496266-2026-00301

  • Several reports describe loose bolts or fasteners in the vertical travel assembly or the arm rotation mechanism. Engineers re-tightened or replaced them, and one report says the system was taken out of use until repair. No patient injury was reported in these cases.

    5 reports: 3005496266-2026-00330, 3005496266-2026-00286, 3005496266-2026-00260, 3005496266-2026-00304, 3005496266-2026-00265

  • Two reports describe electrical arcing or burning, with burnt cables, a burning smell or smoke. Engineers replaced the X-ray tube, generator parts, cables or circuit boards. No patient or user injury was reported.

    3 reports: 3005496266-2026-00291, 3005496266-2026-00285, 3005496266-2026-00292

  • Several reports describe error codes that made the system stop working during or before exams. The causes found included a failed X-ray tube, damaged detector cables, and a fault that persisted after a drag clutch change. Patients were sometimes rescheduled.

    3 reports: 3005496266-2026-00305, 3005496266-2026-00313, 3005496266-2026-00301

  • One report describes horizontal line artifacts (stripes) on contrast-enhanced mammography images. The physician judged the images unsuitable, so the patient needs a repeat exam with more contrast agent. The manufacturer's investigation is ongoing and has not identified the cause.

    Report: 3005496266-2026-00294

Written by AI from the narratives of the 20 newest reports that have one, received Sep 19, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
89in the FDA’s Global Unique Device Identification Database
Establishment listings
25registered establishments that list this product code

Watch OTE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OTE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OTE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.