Product codes

FDA product code

HNL: Probe, Lachrymal (FDA product code)

Follow HNL: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 886.4350
Review panel
Ophthalmic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
100 in the last 12 months
Median review time
32 daysthe latest 10 decisions
Recall records
10 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code HNL per year, by decision date, 10 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K843491 CONCEPT FIBER OPTIC CANALICULUS INTUBAConcept, Inc. Oct 5, 198429 days
K840861 TSE-ANDERSON MODIFIED LACRIMAL GROOVHansen Ophthalmic Development Lab May 9, 198475 days
K833671 STERILE OIL AND GUIDEWIRECooperVision, Inc. Jan 10, 198484 days
K831901 LACIMAL INTUBATION SETSVisitec Co. Jul 12, 198328 days
K813187 PILLING LACRIMAL INTUBATION SYSTEMNarco Scientific Jan 28, 198273 days
K812255 ETHICON LACRIMAL STENTETHICON, Inc. Aug 20, 19818 days
K802845 CONCEPT CANALICULUS INTUBATION SETConcept, Inc. Dec 17, 198035 days
K801232 JACKSON LACRIMAL INTUBATION SETStorz Instrument Co. Jun 17, 198021 days
K800089 CRAWFORD LACRIMAL INTUBATION SETJedmed Instrument Co. Mar 3, 198049 days
K770194 NASO-LACRIMAL DUCT INSERTConcept, Inc. Feb 14, 197714 days

Recalls

Recall records for product code HNL per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1368-2015Class II Quest Medical, Inc.Expiration date incorrectly printed in Manufacturing Date field on both pouch and carton labels Feb 26, 2015

Adverse event reports (MAUDE)

Medical device reports received per year that name product code HNL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20192
20201
20213
20220
20231
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Fragmentation1

In plain English: what the newest reports describe Written by AI

  • The probe or instrument tip broke off during the procedure in several reports, leaving a small piece inside the patient's nose, eye area or tissue. In most reports the piece was later found and removed, often by suction or surgical retrieval, but in some it was not found or its location was unclear.

    14 reports: 3969949, 3928419, 3638680, 1920664-2014-00009, 4043759, 2435879, MW5020861, 1595322, 2242450-2019-00002, 3011137372-2019-00055, MW5095429, MW5101071, 12696871, MW5149376

  • Several reports describe a wire or metal rod that came apart from its handle or hub during use, and in one case a part was left in the tissue and removed with it. The reports do not state why the parts separated.

    3 reports: 12696871, 2242450-2019-00002, 3687367

  • A report describes a retrieval hook that broke at its tip during a tear duct procedure, and the hook was later found in the patient's nose and removed. A follow-up X-ray was taken in that case.

    Report: 3928419

  • In a report about a tear duct procedure, the surgeon could not find the broken tip even after X-ray and endoscope checks, and no further information was given about where it went.

    Report: 1595322

  • One report describes a probe tube that was too soft, hard to pass into the duct, and deformed. The manufacturer received the returned device for review, but the distributor gave no further details.

    Report: 1649914-2016-00027

Written by AI from the narratives of the 20 newest reports that have one, received Nov 6, 2009 to Dec 18, 2023. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
659in the FDA’s Global Unique Device Identification Database
Establishment listings
164registered establishments that list this product code

Watch HNL in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get HNL every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HNL. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.