Product codes

FDA product code

HND: Spatula, Ophthalmic (FDA product code)

Follow HND: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 886.4350
Review panel
Ophthalmic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
60 in the last 12 months
Median review time
23 daysthe latest 6 decisions
Recall records
00 in the last 12 months
Adverse event reports
8last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code HND per year, by decision date, 6 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K863990 THORNTON TITANIUM SILVER SPATULAKeeler Instruments, Inc. Oct 31, 198617 days
K810937 ANIS IRRIGATING SPATULAAmerican V. Mueller May 15, 198138 days
K801609 MADDOX LENS SPATULA CAT. #7245Edward Weck, Inc. Aug 13, 198029 days
K801608 MCCULLEY CONTINUOUS SUTURE TIGHTNEREdward Weck, Inc. Aug 12, 198028 days
K791983 SPATULA'S #'S 7618,7248,7240,7242,5108Edward Weck, Inc. Oct 4, 19799 days
K761253 CYCLODIALYSIS SPAT. 15MM BLADE TITANIUMEdward Weck, Inc. Dec 16, 19763 days

Recalls

Recall records for product code HND per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code HND. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20173
20181
20191
20200
20214
20225
202313
20249
202523
2026 (so far)8

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions7
  • Other or not stated0

Most reported device problems, last 12 months

  1. Break6
  2. Activation Problem1
  3. Material Deformation1
  4. Material Fragmentation1

In plain English: what the newest reports describe Written by AI

  • Multiple reports describe the tip or loop of an eye instrument breaking during surgery, with a piece falling into the eye. Some pieces were removed during the same operation. In others the piece was left in the eye, and in one a CT scan found it and a second procedure removed it.

    9 reports: 3003398873-2026-00165, 3010692967-2026-00023, 3003398873-2025-00388, 3003398873-2025-00355, 2242450-2025-00004, 2242450-2025-00006, 3003398873-2026-00105, 2242450-2025-00002, 2242450-2025-00001

  • Several reports describe loops that were found cut, dull, or broken. In most, the surgeon switched to a new instrument and finished the operation, and no patient harm was reported.

    6 reports: 3003398873-2026-00083, 3003398873-2026-00019, 3003398873-2026-00054, 3003398873-2025-00351, 3003398873-2025-00365, 3003398873-2025-00331

  • Parts sometimes came loose during surgery. One report says a handle detached from its cable and plunged into the retina, the light-sensitive lining at the back of the eye. Another says a loop detached and fell onto the back of the eye.

    2 reports: 3003398873-2025-00352, 3003398873-2025-00396

  • One report says the loop of an instrument failed to pull back properly into its needle, and the loop also broke outside the eye. The surgery was completed the same day.

    Report: 3003398873-2026-00056

Written by AI from the narratives of the 18 newest reports that have one, received Apr 24, 2025 to Aug 6, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2,354in the FDA’s Global Unique Device Identification Database
Establishment listings
169registered establishments that list this product code

Watch HND in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get HND every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HND. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.