Product codes

FDA product code

HNF: Scissors, Ophthalmic (FDA product code)

Follow HNF: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 886.4350
Review panel
Ophthalmic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
150 in the last 12 months
Median review time
28 daysthe latest 15 decisions
Recall records
20 in the last 12 months
Adverse event reports
24last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code HNF per year, by decision date, 15 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K022840 STEPHENS DISPOSABLE SCISSORSStephens Instruments Nov 1, 200266 days
K897093 INTRAOCULAR MICROSCISSORS BY MEANS OF GAMMA RADIA.Microline Pentax, Inc. Apr 4, 1990105 days
K873099 MANUAL OPHTHALMIC SURGICAL INSTRUMENTSAlcon Laboratories Sep 4, 198728 days
K851768 13-550,13-560 WESCOTT SCOSSORS (EYE)Artiberia Jun 20, 198556 days
K822151 SURGICAL INSTRUMENTS REPRESENT. 4 CLASSRobert I. Chien & Assoc., Inc. Aug 19, 198228 days
K821290 LITTAUER SCISSORS 5 1/2Conphar, Inc. May 28, 198224 days
K821286 IRIS SCISSORS STRAIGHT 4 1/2Conphar, Inc. May 28, 198224 days
K811245 OPHTHALMIC SCISSORSKeeler Instruments, Inc. Jul 31, 198188 days
K770040 SCISSORS, STRABIMUS, 4 STRAIGHTJ. Sklar Mfg. Co., Inc. Jan 14, 19774 days
K770041 SCISSORS, STRABISMUS, 4 CURVEDJ. Sklar Mfg. Co., Inc. Jan 14, 19774 days

Recalls

Recall records for product code HNF per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20242
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0950-2025Class II Sklar InstrumentsReports of various packaging issues that may result in a breach of the sterile barrier. Dec 3, 2024
Z-0521-2025Class II MicroSurgical Technology IncDue to pin coming off of handles. Sep 17, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code HNF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20175
20189
201919
202010
202118
202220
202357
202430
202521
2026 (so far)23

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions24
  • Other or not stated0

Most reported device problems, last 12 months

  1. Break8
  2. Dull, Blunt6
  3. Difficult to Open or Close4
  4. Corroded2
  5. Device-Device Incompatibility2
  6. Degraded1

In plain English: what the newest reports describe Written by AI

  • During eye surgery the tip or another part of the scissors broke in several reports, and some pieces fell into the patient's eye. The pieces were removed during the same procedure, and most reports do not state any patient harm.

    6 reports: 3003398873-2026-00040, 3003398873-2026-00041, 3003398873-2025-00376, 3003398873-2025-00429, 3003398873-2026-00101, 1417592-2026-43521

  • Other reports describe scissors found broken or damaged when opened or used, including one that broke on first use. In a returned instrument with a bent tube and blades, the manufacturer could not determine when or why the damage happened.

    5 reports: 3003398873-2025-00410, 3003398873-2025-00386, 1417592-2026-03730, 3003398873-2026-00169, 1417592-2026-60698

  • Scissors were reported to jam, stop opening and closing, or fail to cut during surgery. Where the outcome is given, the surgery was finished with a new pair.

    4 reports: 3003398873-2026-00209, 3003398873-2026-00111, 3003398873-2026-00055, 3003398873-2026-00099

  • Two reports describe scissors that were not sharp enough. One physician reported poor sharpness during surgery, and another report says the tips were blunt rather than sharp.

    2 reports: 3003398873-2026-00193, 1417592-2026-49100

  • Two reports describe a connection problem with the instrument. One says a cutter did not fit properly on the machine, and another says a handle was loose so the forceps tip could not be installed, and the surgery was completed with a different handle.

    2 reports: 3003398873-2026-00220, 3003398873-2026-00084

Written by AI from the narratives of the 20 newest reports that have one, received Sep 19, 2025 to Oct 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
4,003in the FDA’s Global Unique Device Identification Database
Establishment listings
277registered establishments that list this product code

Watch HNF in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get HNF every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HNF. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.