Product codes

FDA product code

PIE: Esophageal Dilator With Balloon And Electrode Sensors (FDA product code)

Follow PIE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5980
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
20 in the last 12 months
Median review time
98 daysthe latest 2 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PIE per year, by decision date, 2 since 2014. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K172128 EsoFLIP® ES-310 Balloon CatheterCrospon, Ltd. Nov 22, 2017131 days
K142000 ESOFLIP ESCrospon, Ltd. Sep 25, 201464 days

Recalls

Recall records for product code PIE per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PIE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20180
20196
20200
20213
20221
20230
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Contamination /Decontamination Problem1

In plain English: what the newest reports describe Written by AI

  • Several reports describe a tear or hole (perforation) in the food pipe during or after balloon dilation. Some patients needed a stent or surgery to repair it, and one report describes a patient who later died. One report says the cause could not be confirmed, and the manufacturer's findings are not stated.

    8 reports: 9681384-2022-00041, 9681384-2021-00012, 9681384-2021-00006, 3006897778-2019-00010, 3006897778-2019-00004, 3006897778-2019-00003, 3006897778-2019-00001, 3006897778-2017-00002

  • Two reports describe a problem with the machine's electronics. One says the syringe would not load and a temperature sensor error appeared, so a repeat procedure with extra anesthesia was needed. The other says the screen froze and the user could not tell whether the balloon was still inflating.

    2 reports: 3006897778-2019-00006, 9681384-2021-00003

  • A study report describes 10 patients with achalasia (a condition where the food pipe muscle does not relax) who were dilated with the balloon. Three had repeat trouble swallowing, and some had chest pain or acid reflux afterward, which were treated with pain medicine and acid-reducing drugs.

    Report: 3006897778-2019-00007

  • One report says the catheter contained floating bits in the fluid. The report states there was no patient involvement.

    Report: 9681384-2026-00674

  • One report describes high-pressure alarms while the balloon was being inflated, even though no widening of the food pipe was seen. It is unknown from the report whether the device caused or contributed to the patient's injury.

    Report: 3006897778-2019-00003

Written by AI from the narratives of the 13 newest reports that have one, received Jun 15, 2017 to Jun 19, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
5in the FDA’s Global Unique Device Identification Database
Establishment listings
12registered establishments that list this product code

Watch PIE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PIE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PIE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.