Product codes

FDA product code

PID: Esophageal Dilator Balloon With Or Without Electrode Sensors (FDA product code)

Follow PID: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5980
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
30 in the last 12 months
Median review time
73 daysthe latest 3 decisions
Recall records
10 in the last 12 months
Adverse event reports
14last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PID per year, by decision date, 3 since 2005. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20191
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K182895 Wilson-Cook Achalasia BalloonWilson-Cook Medical, Inc. Jan 25, 2019102 days
K132337 ESOFLIP BALLOON DILATION CATHETERCrospon, Ltd. Oct 7, 201373 days
K050232 RIGIFLEX SINGLE-USE ACHALASIA BALLOON DILATORBoston Scientific Corp Mar 11, 200538 days

Recalls

Recall records for product code PID per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2038-2024Class II Covidien, LLCDue to saline conductivity issues, their is a potential that dilation catheters may provide inaccurate esophageal diameter measurements that may lead to variou… Apr 25, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PID. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20192
20204
202110
20229
202310
202483
202519
2026 (so far)9

Last 12 months by event type

  • Deaths0
  • Injuries6
  • Malfunctions8
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem5
  2. Contamination /Decontamination Problem4
  3. Device Difficult to Program or Calibrate2
  4. Insufficient Device Problem Information2
  5. Use of Device Problem2
  6. Burst Container or Vessel1

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
7in the FDA’s Global Unique Device Identification Database
Establishment listings
8registered establishments that list this product code

Watch PID in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PID every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PID. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.