FDA product code
KNT: Tubes, Gastrointestinal (And Accessories) (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.5980
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- 510(k) and De Novo decisions
- 6523 in the last 12 months
- Median review time
- 109 daysthe latest 25 decisions
- Recall records
- 26821 in the last 12 months
- Adverse event reports
- 1,841last 12 months, 19 deaths
510(k) and De Novo decisions
Decisions for product code KNT per year, by decision date, 652 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 9 |
| 2018 | 7 |
| 2019 | 10 |
| 2020 | 5 |
| 2021 | 6 |
| 2022 | 7 |
| 2023 | 5 |
| 2024 | 9 |
| 2025 | 4 |
| 2026 (so far) | 3 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262038 | danumed StomaMeterDanumed Medizintechnik GmbH | Sep 30, 2026105 days |
| K261890 | 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®Boehringer Laboratories, LLC | Aug 14, 202670 days |
| K253514 | Minnesota Four-Lumen Esophagogastric Tamponade Tube - 18 French (0092220); Blakemore Esophageal-Nasogastric Tube - 20 French (0092100); Blakemore Esophageal-Nasogastric Tube - 16 French (0092300)C.R. Bard, Inc. | Jul 10, 2026246 days |
| K250389 | XNY Disposable Gastric Calibration TubeChangzhou Xin Neng Yuan Medical Stapler Co.,Ltd | Apr 10, 202558 days |
| K243228 | Flexi-Seal AIR (with ENFit Connector)Convatec | Mar 28, 2025171 days |
| K242336 | hygh-tec Drainage IIAmb Medtec | Jan 17, 2025163 days |
| K242901 | ZZIREN™ Orogastric Tube; ZZIREN™ SGT Orogastric Tube - 32 Fr (ZZ-SGT-32); ZZIREN™ SGT Orogastric Tube - 36 Fr (ZZ-SGT-36); ZZIREN™ SGT Orogastric Tube - 40 Fr (ZZ-SGT-40); ZZIREN™ GBT Orogastric Tube - 32 Fr (ZZ-GBT-32); ZZIREN™ GBT Orogastric Tube - 36 Fr (ZZ-GBT-36); ZZIREN™ GBT Orogastric Tube - 40 Fr (ZZ-GBT-40)Tools For Surgery, LLC | Jan 10, 2025109 days |
| K241169 | Entarik NI Feeding Tube SystemGravitas Medical, Inc. | Nov 22, 2024210 days |
| K241185 | CORGRIP* SR NG/NI Tube Retention SystemAvanos Medical, Inc. | Oct 25, 2024179 days |
| K240965 | CORTRAK* 2 Enteral Access System (20-0950)Avanos Medical, Inc. | Jun 6, 202458 days |
Recalls
Recall records for product code KNT per year, by the date the recall began. Each recalled product is one record; these 268 records belong to 54 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 12 |
| 2018 | 3 |
| 2019 | 2 |
| 2020 | 2 |
| 2021 | 3 |
| 2022 | 1 |
| 2023 | 2 |
| 2024 | 9 |
| 2025 | 19 |
| 2026 (so far) | 20 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-2333-2026Class II | Avanos Medical, Inc.Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. | Apr 30, 2026 |
| Z-2334-2026Class II | Avanos Medical, Inc.Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. | Apr 30, 2026 |
| Z-2335-2026Class II | Avanos Medical, Inc.Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. | Apr 30, 2026 |
| Z-2336-2026Class II | Avanos Medical, Inc.Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. | Apr 30, 2026 |
| Z-2337-2026Class II | Avanos Medical, Inc.Lidocaine hydrochloride injection, the subject of a supplier recall for quality issues, were included into sterile kits and sets. | Apr 30, 2026 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KNT. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 1,672 |
| 2018 | 1,901 |
| 2019 | 1,838 |
| 2020 | 1,641 |
| 2021 | 1,655 |
| 2022 | 1,650 |
| 2023 | 1,863 |
| 2024 | 1,577 |
| 2025 | 1,471 |
| 2026 (so far) | 1,706 |
Last 12 months by event type
- Deaths19
- Injuries677
- Malfunctions1,130
- Other or not stated15
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem483
- Break185
- Material Puncture/Hole140
- Leak/Splash131
- Material Rupture121
- Complete Blockage107
In plain English: what the newest reports describe Written by AI
Patients developed infections where the tube enters the body, called the stoma, and were treated with antibiotics. In one report the tube was later removed and replaced after the infection resolved.
5 reports: 3010757606-2026-00369, 3010757606-2026-00371, 3010757606-2026-00372, 3010757606-2026-00373, 3010757606-2026-00375
Feeding tubes broke or ruptured inside patients, sometimes leaving a piece inside that needed sedation or a scope to remove. Reports describe resistance or a suspected clog before the break, though one said it could not be confirmed that the tube was blocked.
4 reports: 9611594-2026-00747, 9611594-2026-00753, 9611594-2026-00752, 9611594-2026-00750
Feeding tubes developed holes or perforations, letting fluid or medication leak out, including at a seam and near a connector. One report said the patient felt fluid leaking inside the nose, and another said no patient injury occurred.
3 reports: 9611594-2026-00762, 9611594-2026-00765, 9611594-2026-00750
In two reports the internal bumper, the part that holds the tube inside the stomach, became buried in the stomach wall. In one, the planned procedure to remove the tube was canceled and the device stayed in place.
2 reports: 3010757606-2026-00379, 3010757606-2026-00373
In one report a feeding tube was placed into a patient's lung, causing a collapsed lung (pneumothorax) that needed a right chest tube. The patient was already on a breathing tube, and the placement was done by a newly trained nurse under supervision.
Report: 3011270181-2026-00184
Written by AI from the narratives of the 19 newest reports that have one, received Oct 26, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 8,280in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 688registered establishments that list this product code
Other codes under 21 CFR 876.5980
Product codes classified under the same regulation.
Watch KNT in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KNT every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KNT. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KNTRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNTRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KNT · count decision_dateRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:KNTRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNT · count event_date_initiatedRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KNT · count res_event_numberRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-2333-2026" "Z-2334-2026" "Z-2335-2026" "Z-2336-2026" "Z-2337-2026")Retrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNT AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNT AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KNT AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KNTRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KNTRetrieved Nov 29, 2026, 8:56 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.5980Retrieved Nov 28, 2026, 9:33 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil