Product codes

FDA product code

LYU: Accessory, Surgical Apparel (FDA product code)

Follow LYU: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 878.4040
Review panel
General Hospital
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
560 in the last 12 months
Median review time
133 daysthe latest 25 decisions
Recall records
90 in the last 12 months
Adverse event reports
4last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code LYU per year, by decision date, 56 since 1988. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K011755 STRYKER T4 HYTREL (R) TOGASStryker Corp. Jun 22, 200116 days
K965237 NURSES BOUFFANT CAPCopioumed Intl., Inc. Aug 27, 1997239 days
K970988 FAR-EAST BOUFFANT CAPSFar East Science & Technology Development Co., Ltd. Jul 10, 1997114 days
K964364 DISPOSABLE APRONInstrument Makar, Inc. Feb 25, 1997116 days
K961791 DEPUY DISPOSABLE FILTER/HOODDepuy, Inc. Aug 9, 199692 days
K961454 AMMI MAGNI-GUARDAmerican Medical Mfg., Inc. Jul 25, 1996101 days
K945302 SLOAN STA-DRI PANT PROTECTORSloan Corp. Mar 19, 1996567 days
K954314 ULTRAFIT LINERSStahmer Weston Scientific Dec 28, 1995104 days
K953089 I-SPOUSEProducts For Medicine Oct 16, 1995105 days
K952303 SPLASH ASSISTInnovative Outsourcing Solutions Aug 24, 1995100 days

Recalls

Recall records for product code LYU per year, by the date the recall began. Each recalled product is one record; these 9 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20216
20220
20232
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2201-2023Class II MEDLINE INDUSTRIES, LP - NorthfieldProbe covers for use during diagnostic ultrasound procedures may have an inadequate barrier at the seams. May 18, 2023
Z-2329-2023Class II MEDLINE INDUSTRIES, LP - NorthfieldPotential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications. May 15, 2023
Z-1078-2021Class II Cardinal Health 200, LLCGowns included in the kits potentially have rips, holes, tears, incomplete and/or open seams, staining, foreign material or debris on the gowns. Jan 7, 2021
Z-1079-2021Class II Cardinal Health 200, LLCGowns included in the kits potentially have rips, holes, tears, incomplete and/or open seams, staining, foreign material or debris on the gowns. Jan 7, 2021
Z-1080-2021Class II Cardinal Health 200, LLCGowns included in the kits potentially have rips, holes, tears, incomplete and/or open seams, staining, foreign material or debris on the gowns. Jan 7, 2021

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LYU. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201711
20181
20191
20209
20212
20224
20230
20243
20255
2026 (so far)3

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions4
  • Other or not stated0

Most reported device problems, last 12 months

  1. Component Misassembled1
  2. Contamination /Decontamination Problem1
  3. Delivered as Unsterile Product1
  4. No Apparent Adverse Event1
  5. Shielding Failure1

In plain English: what the newest reports describe Written by AI

  • Eyewear (protective glasses or shields) can fall off or detach during use. Reports describe frames that were bent or did not fit, and one report says glasses fell into a surgical wound during suturing. Another says a head-worn item fell into the sterile field during a procedure.

    4 reports: 2182318-2026-00035, 2182318-2020-00001, 2182318-2025-00057, 2182318-2024-00119

  • Several reports describe skin or allergic reactions. One report says a gown's wrist cuff caused an allergic reaction that the customer blamed on latex. Another describes an employee wearing a labeled latex-free item who had reactions including swelling and dizziness, and a report describes a skin rash around the eyes in two staff wearing eye shields.

    4 reports: 3004824601-2025-00226, 1451040-2022-00059, 2182318-2022-00105, MW5096778

  • Some reports describe masks, shields or other head coverings that fastened poorly or caused discomfort. One says ear loops disconnected or broke on first removal, and another says a head covering fell off when a patient coughed. Users also reported headaches, trouble hearing, breathing difficulty and anxiety while wearing masks or coverings.

    4 reports: 10634847, 3012307300-2021-11185, MW5096642, MW5100159

  • Shoe covers (worn over footwear in surgery) have poor grip. Reports describe the anti-slip tread coming off, which can stick to the floor instead of the boot, and a surgeon who slid and nearly fell even on a dry floor. One report says a surgical assistant fell and hurt their back, and the reporter said there were no injuries at the site in another report.

    3 reports: 3014421917-2025-00034, 3014421917-2024-00016, 3014421917-2024-00014

  • Gowns, masks and other items reported contamination. One report says bunny suits (full-body coveralls) were found with debris and hairs inside the overwrap package, and another says coveralls had small bugs when opened. A towel was found stained when opened.

    3 reports: MW5178192, MW5109939, 50220877

Written by AI from the narratives of the 20 newest reports that have one, received Sep 14, 2020 to Aug 12, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2,165in the FDA’s Global Unique Device Identification Database
Establishment listings
838registered establishments that list this product code

Watch LYU in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LYU every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LYU. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.