Device class
Class I
Regulation
21 CFR 878.4040
Review panel
General Hospital
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FXZ per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code FXZ per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FXZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201722
201813
20194
20204
20214
20224
20236
20240
20251
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Defective Device1
  2. Output Problem1
  3. Sharp Edges1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the device overheating. Where the reports state whether a patient was involved, they say there was no patient impact. The reports do not say what caused the overheating.

    7 reports: 0001811755-2020-00401, 3015967359-2021-00547, 3015967359-2021-00548, 3015967359-2021-02436, 3015967359-2022-01369, 3015967359-2023-01524, 3015967359-2025-99163

  • One report says the bottom edge of the clear plastic hood cut clinicians' hands when the hood was removed, which is a concern if the clinician has been treating a patient with a blood-borne pathogen. The same report says the manufacturer is replacing the product.

    Report: 50838958

  • One report says that when the surgeon pulled out a guide rod through a nail, the rod stuck and the whole nail had to be removed. The nail's inner insert had failed, and a new nail was used, causing a 30-minute delay. The patient had no reported consequences.

    Report: 8030965-2023-00995

  • One report says the aiming arm broke where it connects to the insertion handle. The report says this was the second such break within three months, but gives no further details.

    Report: 8030965-2023-07165

  • One report says that during insertion of a nail into a heavier patient, the surgeon met resistance and the inner trocar bent. The surgeon then switched to a different implant, and the surgery was completed without delay.

    Report: 8030965-2023-10260

Written by AI from the narratives of the 15 newest reports that have one, received Feb 4, 2020 to Sep 21, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
33in the FDA’s Global Unique Device Identification Database
Establishment listings
22registered establishments that list this product code

Watch FXZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FXZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FXZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.