Product codes

FDA product code

FXX: Mask, Surgical (FDA product code)

Follow FXX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4040
Review panel
General Hospital
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
6077 in the last 12 months
Median review time
246 daysthe latest 25 decisions
Recall records
120 in the last 12 months
Adverse event reports
73last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FXX per year, by decision date, 607 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20183
20194
202027
2021218
202291
202322
202415
20256
2026 (so far)5

Latest decisions

NumberDevice and applicantDecision and review time
K251967 HALYARD* FLUIDSHIELD* 3 Fog-Free Procedure Mask with SO SOFT* Lining and SO SOFT* Earloops; HALYARD* FLUIDSHIELD* 3 Fog-Free Procedure Mask with SO SOFT* Lining and SO SOFT* Earloops with WrapAround VisorO&M Halyard, Inc. Mar 18, 2026265 days
K252534 Surgical Face Mask (Ear mount)Zhejiang Hangkang Medical Equipment Co., Ltd. Mar 3, 2026203 days
K253398 Disposable Surgical Mask (Non-Sterile) (EFX3PLBLKMSK300)Efofex, Inc. Feb 19, 2026142 days
K252830 Disposable Surgical Face Mask (3P00B, C2900)Beatles Medical Supplies (Xiantao) Co., Ltd. Jan 12, 2026129 days
K252650 Disposable Medical Face MaskMakrite Industries, Inc. Jan 5, 2026136 days
K243342 KP Protective Face MaskKp Trading Co., Ltd. Dec 22, 2025423 days
K252941 HALYARD* Adult Face Mask with SO SOFT* Lining and SO SOFT* EarloopsO&M Halyard, Inc. Dec 11, 202587 days
K252964 PRIMED Surgical and Procedure MasksPrimed Medical Products, Inc. Nov 4, 202548 days
K251902 Vitaform Procedural Mask - Blue (Vitaform Blue); Vitaform Procedural Mask with Shield (Vitaform-FS)Vitacore Industries, Inc. Sep 17, 202589 days
K250082 Procedure mask/Surgical mask/Face maskWinner Medical Co., Ltd. Jun 18, 2025156 days

Recalls

Recall records for product code FXX per year, by the date the recall began. Each recalled product is one record; these 12 records belong to 7 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20192
20200
20210
20220
20234
20242
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0728-2025Class II O&M HALYARD, INC.Not meeting the bioburden testing requirements of EN 14683 required for masks sold in Europe. Face masks sold in the United States are not required to meet thi… Nov 8, 2024
Z-0729-2025Class II O&M HALYARD, INC.Not meeting the bioburden testing requirements of EN 14683 required for masks sold in Europe. Face masks sold in the United States are not required to meet thi… Nov 8, 2024
Z-1146-2024Class II AMD Medicom Inc.Level 3 masks were produced on alternate non-validated production equipment that were not included as part of the initial qualification of the products. Dec 21, 2023
Z-1147-2024Class II AMD Medicom Inc.Level 3 masks were produced on alternate non-validated production equipment that were not included as part of the initial qualification of the products. Dec 21, 2023
Z-1148-2024Class II AMD Medicom Inc.Level 3 masks were produced on alternate non-validated production equipment that were not included as part of the initial qualification of the products. Dec 21, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FXX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201745
201821
201923
202060
202167
202221
202321
202421
202511
2026 (so far)70

Last 12 months by event type

  • Deaths0
  • Injuries11
  • Malfunctions59
  • Other or not stated3

Most reported device problems, last 12 months

  1. Detachment of Device or Device Component14
  2. Loss of or Failure to Bond11
  3. Break9
  4. Material Split, Cut or Torn7
  5. Adverse Event Without Identified Device or Use Problem5
  6. Material Fragmentation5

In plain English: what the newest reports describe Written by AI

  • Ear loops and straps on the masks break, tear away, or pop off the mask, sometimes when the mask is taken out of the box or put on. One report says the ear loops broke on 4 of 6 masks after only a few minutes of wear.

    6 reports: 1417592-2026-54493, 1417592-2026-48524, 1417592-2026-45945, 1417592-2026-46927, 1417592-2026-36147, 1417592-2026-48760

  • Some reports are brief or lack detail. One says the strip under the foam on the nose piece was peeling off, one says the cheek strips break and fall off, one says the mask broke and snapped, one says it was defective, and one says it detached. A box had spots the manufacturer said came from manufacturing.

    6 reports: 1417592-2026-52806, 1417592-2026-55557, 1417592-2026-47324, 1417592-2026-53475, 1417592-2026-54098, MW6003419

  • The plastic shield attached to the mask came loose during use, in some cases in the middle of a surgery. One nurse had to remove the shield to finish the procedure, which the report says risked splashes without proper protective equipment.

    4 reports: 1417592-2026-09309, 50128432, 1417592-2026-07265, 1417592-2026-60700

  • Users reported skin reactions. Two employees developed a rash around the mouth and chin after their first day of wear, and one patient reported an itchy, runny nose. In another report, the manufacturer noted one facial rash.

    3 reports: 1319130-2026-00008, MW6002730, 1417592-2026-60700

  • One report describes pieces of ear loop string found in the mask boxes. A hygienist said she inhaled a piece, coughed one piece out about an inch long, and kept coughing. She went to urgent care, vomited several times, and was released. The mask lot was not provided.

    Report: 1319130-2026-00009

Written by AI from the narratives of the 20 newest reports that have one, received Jul 21, 2026 to Oct 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2,280in the FDA’s Global Unique Device Identification Database
Establishment listings
624registered establishments that list this product code

Watch FXX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FXX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FXX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.