Blog

MAUDE

How to search the MAUDE database for medical device reports

A step-by-step guide to the FDA MAUDE database: which search fields to use, how to read a medical device report, its limits, and where AEMS fits in 2026.

Title card reading "How to search the MAUDE database for medical device reports"

A complaint comes in, or a competitor's device is in the news, and you need to know what has already been reported to the FDA. The MAUDE search form has more than a dozen fields, stops at 500 results, and labels some things on the report page differently from the form.

The short answer: open the MAUDE advanced search, enter the three-letter product code and a "Date Report Received by FDA" range, and add an event type if you only need deaths or serious injuries. Keep each search under 500 results by narrowing the dates. For anything older than ten years or larger than 500 records, use the FDA's MDR data files or the openFDA API instead.

This post covers the search fields, how to read a single report, the limits to write into every search record, and where AEMS fits.

What the MAUDE database holds

MAUDE (Manufacturer and User Facility Device Experience) holds medical device reports (MDRs) submitted to the FDA. The MAUDE search page names two kinds of reporter: mandatory reporters (manufacturers, importers and device user facilities) and voluntary reporters (health care professionals, patients and consumers).

Three facts shape every search:

  • Ten years. The searchable database holds roughly the last ten years of reports. Older reports are in the MDR data files.
  • Monthly updates. The FDA updates MAUDE monthly, with reports received through the last day of the previous month.
  • Gaps for older alternative reports. Reports made under exemptions, variances or alternative reporting (21 CFR 803.19) before June 2019 may not be in the search. They are in the data files.

MAUDE is also mid-move. The FDA's MDR data files page says MAUDE data will become available in its Adverse Event Monitoring System (AEMS) in 2026. On November 2, 2026, the MAUDE search page and report pages still loaded. Our guide to MAUDE and AEMS tracks what has changed and what to update in your procedures.

How to run a MAUDE search, step by step

Use the advanced search form. Simple search looks for any words in reports received in one selected year, which helps for a phrase but is noisy for a device.

  1. Find the product code. Product codes are three-letter codes from the FDA's product classification database, such as DQA for oximeters. Brand names are spelled many ways across reports; product codes aren't. Our post on FDA product code lookup shows how to find yours.
  2. Enter it in "Product Code".
  3. Set "Date Report Received by FDA". This is the date the FDA received the report, not the date of the event. It is the right field for "what's new since my last check".
  4. Choose an "Event Type" if you need one. The options are Death, Serious Injury, Malfunction, Other and No Answer Provided.
  5. Narrow further only when needed. The form also has Manufacturer, Brand Name, Model Number, Report Number, PMA/510K Number, UDI-Device Identifier, Exemption Number, Summary Report (Yes or No), and two long dropdowns, Product Problem and Product Class.
  6. Pick "Records per Report Page" (5, 10, 25, 50 or 100) and select Search Database.
  7. If you get 500 results, split the date range. Both simple and advanced search return at most 500 records. Halve the date range until each search comes back under 500.

Write down the fields you used and the date you searched. Counts change monthly as new reports and follow-ups arrive.

How to read a medical device report

Each result opens a report page. On the report pages we checked on November 2, 2026, the FDA labels the codes "Medical Device Problem Code" and "Health Effect - Clinical Code". Older SOPs and screenshots may call them "Device Problem" and "Patient Problem". The fields that matter most:

Field on the report pageWhat it tells youRead it with care because
Type of Reportable EventDeath, Serious Injury, Malfunction or OtherIt is the reporter's classification, not an FDA finding
Medical Device Problem CodeWhat went wrong with the device, such as "Gas/Air Leak (2946)"Codes follow IMDRF Annex A and are chosen by the reporter
Health Effect - Clinical CodeThe patient's signs or symptoms, such as "Low Oxygen Saturation (2477)"Malfunctions with no patient involved can carry 4582, "No Clinical Signs, Symptoms or Conditions"
Event or Problem DescriptionThe account of what happenedTrade secrets show as (b)(4) and personal details as (b)(6)
Additional Manufacturer NarrativeThe manufacturer's investigationCheck "Was Device Evaluated by Manufacturer?" before trusting a root cause
Reporter Type and Report SourceWho filed (manufacturer, importer, user facility or voluntary) and who told them, such as a health professionalOne event can produce several reports, one per reporter
Summary Report (Y/N) and Number of Events SummarizedWhether one record stands for several eventsCounting rows undercounts events when summary reports are included
Type of ReportInitial or follow-upMAUDE shows the most recent information for the report

The report number also tells you who filed. Mandatory reports carry the submitter's identifier, the year and a sequence number. Voluntary reports start with "MW". The MDR Report Key is the number that links one report across the FDA's data files.

The FDA's page on how to code an MDR explains the code sets. Reporters are asked to pick the most specific code that fits, so the same failure can appear under a parent code in one report and a child code in another.

The FDA's About MAUDE page is direct about what MDR data can't do. Carry these limits into any document that cites MAUDE:

  • No rates. The FDA says MDR data isn't meant for evaluating adverse event rates or comparing them across devices. MAUDE has no count of devices in use.
  • Passive surveillance. Events are under-reported, reports can be incomplete or inaccurate, and the FDA doesn't verify that the device caused the event.
  • Duplicates. One event can have several reports, one per reporting source, for example a user facility and the manufacturer.
  • No admission. Under 21 CFR 803.16, a report isn't an admission that the device caused or contributed to the event.
  • Search limits. 500 records per search and about ten years of data.

When to use the MDR data files or openFDA instead

MDR data files. The FDA publishes zipped, pipe-delimited files, updated monthly: mdrfoi (the master event record), device, foitext (narratives), patient, linking files for device problem and patient problem codes, and lookup lists for the codes. Every file joins on the MDR REPORT KEY, and several exceed 1 GB uncompressed. The files reach further back than the search: user facility reports since 1991, voluntary reports since June 1993 and manufacturer reports since August 1996.

openFDA. The device adverse event API serves MAUDE data as JSON and updates weekly. It is the better tool for counts by event type or device problem. Because the API and the MAUDE search update on different schedules, their counts for the same query can differ on the same day.

Search every MAUDE field at once

The MAUDE form only finds a word in the box you typed it into. If a report says "pulse oximeter" in its common name or narrative but its brand name is a model number, the Brand Name box misses it.

DeviceVigil's free search at devicevigil.com/search looks for your words in every field the MAUDE form offers, at once: brand, common name, manufacturer, model, catalog number, product code, 510(k) or PMA number, report number, UDI-DI, device problem, patient problem and the narrative. It shows how many reports matched in each field, so one tap narrows back to a single field. In openFDA data as of November 11, 2026, "pulse oximeter" in the brand name field alone finds 2,946 reports; in any field, 6,236 reports contain both words.

The same search covers product codes, 510(k)s and De Novos, PMAs, recalls and GUDID, and builds a year-by-year report. For pulse oximeters it shows 537 MAUDE reports received in 2026 through October 29, against 106 in all of 2025, and "No Audible Alarm" (1,268 reports) as the most reported device problem across all years. Counts like these say where to read, not how often devices fail.

How DeviceVigil lists a device's reports

DeviceVigil is a Chrome and Edge extension that opens a side panel beside the FDA's 510(k), De Novo, PMA, classification and recall pages. For the record on screen, it lists the individual MAUDE reports for that record's product code, and for a 510(k), De Novo or PMA, the reports about that device only: ones that cite its submission number, or carry its brand under its product code. Each report says which rule matched, and other makers' reports move to a Competitors tab.

You can filter them by event type (death, injury, malfunction), by date received (last 3, 6 or 12 months, or a custom range), by brand, by manufacturer, or by the 510(k), De Novo or PMA number a report cites. Each report links to its FDA report page and its raw openFDA record. A trend chart shows reports over time.

DeviceVigil reads from openFDA, not from the MAUDE search screens, so it follows openFDA's weekly schedule and carries the same limits listed above. Every section shows its exact openFDA query, when it was retrieved and when the FDA last updated the data. To see yearly report counts for one code without the extension, open /codes/DQA/.

See it beside the FDA record

DeviceVigil is a Chrome and Edge extension for regulatory, quality and post-market teams. Open a 510(k), PMA, classification or recall page and see that device type’s clearances, recalls and MAUDE reports in one panel, and get told when something changes.

Add to Chrome — free See how it works

Frequently asked questions

Is the MAUDE database still available in 2026?

Yes. On November 2, 2026, the MAUDE search and report pages on accessdata.fda.gov still loaded. The FDA says MAUDE data will become available in its Adverse Event Monitoring System (AEMS) during 2026, so expect the search to change. Our MAUDE and AEMS guide tracks the move.

How far back does MAUDE go?

The MAUDE search covers about the last ten years of reports. Older reports are in the FDA's MDR data files, which go back to 1991 for user facility reports and August 1996 for manufacturer reports.

Why does my MAUDE search stop at 500 results?

Both simple and advanced search return at most 500 records. Split the date range into smaller pieces, or use the MDR data files or the openFDA API for larger pulls.

Can MAUDE tell me how often a device fails?

No. MAUDE has no data on how many devices are in use, not every event is reported, and one event can be reported more than once. Use it to see which kinds of problems are reported, and use your own complaint and distribution data for rates.

Sources

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This post describes public FDA sources and regulations; it isn’t regulatory or legal advice.