Product codes

FDA product code

PMX: Absorbable Collagen Hemostatic Agent With Thrombin (FDA product code)

Follow PMX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
21 CFR 878.4490
Review panel
General and Plastic Surgery
Premarket route
PMA
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
PMA decisions
694 original PMAs, the rest supplements
Median review time
29 daysthe latest 25 decisions
Recall records
20 in the last 12 months
Adverse event reports
5last 12 months, 0 deaths

PMA decisions

Original PMAs and supplements for product code PMX per year, by decision date, 69 since 1999. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20178
201811
201916
202010
20215
20224
20231
20243
20254
2026 (so far)2

Latest decisions

NumberDevice and applicantDecision and review time
P170012 S032 HEMOBLAST™ BellowsDilon Technologies, Inc. Sep 3, 202666 days
P170012 S031 HEMOBLAST® BellowsDilon Technologies, Inc. Apr 28, 2026291 days
P990009 S077 Floseal Hemostatic Matrix, Floseal with Recothrom; Floseal Hemostatic Matrix, Floseal Fast Prep; 3 Floseal Hemostatic MaBaxter Healthcare Corp Nov 13, 202534 days
P990009 S076 FLOSEAL MATRIX/FLOSEAL MATRIX HEMOSTATIC SEALANT/PROCEED HEMOSTATIC SEALANTBaxter Healthcare Corp Jun 30, 20253 days
P170012 S030 HEMOBLAST™ BellowsDilon Technologies, Inc. Mar 31, 202528 days
P990009 S075 Floseal Hemostatic MatrixBaxter Healthcare Corp Jan 30, 20252 days
P170012 S029 HEMOBLAST™ BellowsDilon Technologies, Inc. Nov 6, 202490 days
P990009 S074 Floseal Hemostatic Matrix, Floseal with Recothrom, Floseal Hemostatic Matrix, Floseal Fast PrepBaxter Healthcare Corp Aug 15, 202410 days
P990009 S073 Floseal Hemostatic MatrixBaxter Healthcare Corp Jan 10, 202428 days
P990009 S070 Floseal Hemostatic Matrix, RT5Baxter Healthcare Corp Feb 2, 2023232 days

Recalls

Recall records for product code PMX per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20181
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0667-2024Class II Baxter Healthcare CorporationCardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align w… Dec 6, 2023
Z-2957-2018Class II Baxter Healthcare CorporationBaxter r recalled this device due to the use of an incorrect plastic formulation in the manufacture of the blue luer component of the FLOSEAL malleable tips. May 30, 2018

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PMX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20181
20192
20201
20212
20220
20235
20245
20255
2026 (so far)5

Last 12 months by event type

  • Deaths0
  • Injuries3
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem2
  2. Clumping in Device or Device Ingredient1
  3. Device Damaged Prior to Receipt by User1
  4. Manufacturing, Packaging or Shipping Problem1
  5. Off-Label Use1
  6. Unexpected Color1

In plain English: what the newest reports describe Written by AI

  • Two reports describe problems with the product's mixing and application. One report says the product clogged after mixing and before use, and another says a mixed product clogged a drain. A third report says the saline would not mix with the thrombin component, and another says the product was too dry to apply during gallbladder removal surgery.

    4 reports: MW5149330, 3007702492-2021-00001, MW5095466, 19527204

  • One report describes a serious allergic reaction. One report describes anaphylactic symptoms after the product was applied during a gynecological procedure, with the patient admitted to intensive care and later recovering. The other report is a different case of a possible hepatitis B infection linked to a device implanted about ten years earlier, not the same problem.

    Report: 1416980-2026-01520

  • One report describes a possible hepatitis B infection in a patient who had a device placed during a mitral valve procedure about ten years earlier. The patient had no other known exposures, but the report does not confirm the product caused the infection.

    Report: 1416980-2025-03448

  • One report describes a blood clot in the portal vein after the product was used to stop bleeding during a pancreas surgery. The patient was treated with blood thinners and clot removal, and was reported to have recovered.

    Report: 1416980-2024-07604

  • One report describes an infection at the surgical site after a lower spinal procedure, with Candida albicans found in blood cultures. The report does not say what treatment was given.

    Report: 1416980-2025-00108

Written by AI from the narratives of the 14 newest reports that have one, received Jul 9, 2020 to May 1, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
13in the FDA’s Global Unique Device Identification Database
Establishment listings
12registered establishments that list this product code

Watch PMX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PMX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PMX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.