FDA product code
LMF: Agent, Absorbable Hemostatic, Collagen Based (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class III
- Regulation
- 21 CFR 878.4490
- Review panel
- General and Plastic Surgery
- Premarket route
- PMA
- Implant
- Yes
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- PMA decisions
- 52613 original PMAs, the rest supplements
- Median review time
- 28 daysthe latest 20 decisions
- Recall records
- 271 in the last 12 months
- Adverse event reports
- 91last 12 months, 2 deaths
PMA decisions
Original PMAs and supplements for product code LMF per year, by decision date, 526 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 12 |
| 2018 | 16 |
| 2019 | 23 |
| 2020 | 15 |
| 2021 | 27 |
| 2022 | 16 |
| 2023 | 20 |
| 2024 | 18 |
| 2025 | 16 |
| 2026 (so far) | 15 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| P800002 S036 | Avitene Microfibrillar Collagen Hemostat (MCH) Non-Woven Web WebberC.R. Bard, Inc. | Sep 29, 202625 days |
| P810006 S115 | Collastat™ Absorbable Collagen Hemostatic Sponge and Collastat™ Absorbable Collagen Hemostatic Agent - Microfibrillar FoIntegra LifeSciences Corporation | Sep 18, 202628 days |
| P990004 S080 | SURGIFOAM® Absorbable Gelatin SpongeFerrosan Meidcal Devices A/S | Sep 18, 2026177 days |
| P850010 S119 | Helistat® Absorbable Collagen Hemostatic Agent and Helitene® Absorbable Collagen Hemostatic Agent- Fibrillar FormIntegra LifeSciences Corporation | Sep 18, 202628 days |
| P800002 S035 | Avitene Microfibrillar Collagen Hemostat (MCH) Non-Woven WebC.R. Bard, Inc. | Jul 15, 202623 days |
| P990004 S081 | SURGIFOAM® Absorbable Gelatin SpongeFerrosan Meidcal Devices A/S | Jun 17, 202626 days |
| P850010 S118 | Helistat® Absorbable Collagen Hemostatic Agent and Helitene® Absorbable Collagen Hemostatic Agent - Fibrillar FormIntegra LifeSciences Corporation | Jun 4, 202627 days |
| P810006 S114 | Collastat™ Absorbable Collagen Hemostatic Sponge and Collastat™ Absorbable Collagen Hemostatic Agent - Microfibrillar FoIntegra LifeSciences Corporation | Jun 4, 202627 days |
| P850010 S117 | Helistat® Absorbable Collagen Hemostatic AgentIntegra LifeSciences Corporation | May 27, 202630 days |
| P810006 S113 | Collastat™ Absorbable Collagen Hemostatic SpongeIntegra LifeSciences Corporation | May 27, 202630 days |
Recalls
Recall records for product code LMF per year, by the date the recall began. Each recalled product is one record; these 27 records belong to 10 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 2 |
| 2024 | 1 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1896-2026Class II | Davol, Inc.Potential for product to contain foreign matter, confirmed to be inspect fragments. | Mar 25, 2026 |
| Z-1881-2024Class II | Ethicon, Inc.Some applicator tips from these lots had open seals. | Apr 23, 2024 |
| Z-0661-2024Class II | Baxter Healthcare CorporationCardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align w… | Dec 6, 2023 |
| Z-0662-2024Class II | Baxter Healthcare CorporationCardiovascular Surgery marketing brochure (US-AS46-220001) that was distributed for the products listed below contains inaccurate content that does not align w… | Dec 6, 2023 |
| Z-1584-2022Class II | Mckesson Medical-Surgical Inc. Corporate OfficeFacility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lo… | May 25, 2022 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code LMF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 121 |
| 2018 | 109 |
| 2019 | 151 |
| 2020 | 146 |
| 2021 | 96 |
| 2022 | 58 |
| 2023 | 271 |
| 2024 | 134 |
| 2025 | 94 |
| 2026 (so far) | 86 |
Last 12 months by event type
- Deaths2
- Injuries71
- Malfunctions18
- Other or not stated0
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem33
- Off-Label Use22
- Patient Device Interaction Problem16
- Lack of Effect7
- Device Handling Problem6
- No Apparent Adverse Event4
In plain English: what the newest reports describe Written by AI
Allergic reactions: two reports describe a published study of two children who developed hives after gelatin sponge was placed in the liver during procedures. A third report says a user had an allergic reaction to the sponge, with no further details.
3 reports: 1810189-2026-00019, 1810189-2026-00020, 3008478369-2026-00036
Material entering blood vessels: in one report, a child's lung artery was blocked by clumps of the material and clots and needed a heart-lung machine, and the child recovered. In another, a patient had a brainstem stroke and died after the material was applied; the reporter suspects it entered a vessel.
2 reports: 3008478369-2026-00041, 3008478369-2026-00038
Wound infection and drainage after spine surgery: two reports describe patients with wound drainage and fever after gelatin fluid was used in spine surgery, and one reports Gram-negative bacteria grew in cultures. The reports do not state that the material caused these problems.
2 reports: 3008478369-2026-00037, 3008478369-2026-00033
Expired products used: two reports describe expired products used during surgery, one in a spine procedure and one in a skull procedure. The spine case was unintentional and no consequences were declared, while the outcome of the skull case is unknown.
2 reports: 3008478369-2026-00035, 3008478369-2026-00034
Nerve pressure after surgery: one report describes two patients who developed leg symptoms days after endoscopic spine surgery, which the authors linked to the material expanding and pressing on nerves.
Report: 3008478369-2026-00040
Written by AI from the narratives of the 15 newest reports that have one, received Sep 9, 2026 to Oct 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 59in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 44registered establishments that list this product code
Other codes under 21 CFR 878.4490
Product codes classified under the same regulation.
Watch LMF in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get LMF every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LMF. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:LMFRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LMFRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LMF · count decision_dateRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/pma · search product_code:LMF · count pma_numberRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:LMFRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:LMF · count event_date_initiatedRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:LMF · count res_event_numberRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1896-2026" "Z-1881-2024" "Z-0661-2024" "Z-0662-2024" "Z-1584-2022")Retrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LMF AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LMF AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:LMF AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 2:22 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:LMFRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:LMFRetrieved Nov 29, 2026, 9:37 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.4490Retrieved Nov 29, 2026, 9:19 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil