Product codes

FDA product code

LMG: Agent, Absorbable Hemostatic, Non-Collagen Based (FDA product code)

Follow LMG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
21 CFR 878.4490
Review panel
General and Plastic Surgery
Premarket route
PMA
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
PMA decisions
1804 original PMAs, the rest supplements
Median review time
100 daysthe latest 9 decisions
Recall records
40 in the last 12 months
Adverse event reports
209last 12 months, 1 death

PMA decisions

Original PMAs and supplements for product code LMG per year, by decision date, 180 since 1960. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20173
20186
201919
202011
202111
20229
202313
202413
202511
2026 (so far)11

Latest decisions

NumberDevice and applicantDecision and review time
P050038 S046 Arista™ AH FlexiTip XL-R ApplicatorDavol, Inc. Nov 12, 202644 days
P210036 S010 PerClot Absorbable Hemostatic Powder Accessory TipsBaxter Healthcare Corporation Nov 7, 2026100 days
P210036 S009 PerClot® Polysaccharide Hemostatic SystemBaxter Healthcare Corporation Aug 7, 2026151 days
P210036 S008 PerClot® Polysaccharide Hemostatic SystemBaxter Healthcare Corporation Aug 7, 2026161 days
P050038 S044 Arista™ AHDavol, Inc. Jul 15, 202623 days
P210036 S007 PerClot® Polysaccharide Hemostatic SystemBaxter Healthcare Corporation Jun 8, 2026167 days
P050038 S043 Arista™ AHDavol, Inc. Apr 29, 202629 days
P210036 S005 PerClot® Polysaccharide Hemostatic SystemBaxter Healthcare Corporation Apr 25, 202588 days
P210036 S002 PerClot Polysaccharide Hemostatic SystemBaxter Healthcare Corporation Dec 20, 2024282 days

Recalls

Recall records for product code LMG per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20242
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0811-2026Class II GET TESTED INTERNATIONAL ABDistribution without premarket approval/clearance. Nov 3, 2025
Z-0812-2026Class II GET TESTED INTERNATIONAL ABDistribution without premarket approval/clearance. Nov 3, 2025
Z-2406-2024Class II Ethicon Sarl, a Johnson & Johnson CompanySome foil pouches were found torn open, impacting the sterile barrier which was traced to a specific machine used during product packaging. Jun 11, 2024
Z-2407-2024Class II Ethicon Sarl, a Johnson & Johnson CompanySome foil pouches were found torn open, impacting the sterile barrier which was traced to a specific machine used during product packaging. Jun 11, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LMG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201730
201884
2019120
2020173
2021209
2022144
2023212
2024233
2025230
2026 (so far)187

Last 12 months by event type

  • Deaths1
  • Injuries154
  • Malfunctions54
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem148
  2. Device Contaminated During Manufacture or Shipping29
  3. Delivered as Unsterile Product7
  4. Device Markings/Labelling Problem7
  5. Patient-Device Incompatibility6
  6. Structural Problem6

In plain English: what the newest reports describe Written by AI

  • Several reports describe the hemostat (a absorbable powder or gauze used to stop bleeding) being found defective before or during use: fibers clumping when torn, a woven structure that looked like an incomplete manufacturing process, a foreign or black substance on the gauze, or an unsealed or damaged package. In these cases the product was replaced and no patient harm was reported.

    6 reports: 2210968-2026-10795, 2210968-2026-10668, 2210968-2026-10677, 2210968-2026-10653, 2210968-2026-10128, 2210968-2026-09742

  • Two reports describe a delayed skin rash appearing about three weeks after surgery in patients who had powder sprayed on soft tissue during hip replacement. One patient was treated with oral steroids and an antihistamine; the surgeon could not say whether the cause was an allergy or a drug reaction.

    2 reports: 2210968-2026-10753, 2210968-2026-10553

  • Two reports describe a serious complication after brain or spine surgery. One reports postoperative swelling after use on the brain surface that required a repeat opening of the skull. Another reports poor healing and a severe tissue reaction around the gauze after spinal surgery, requiring a second operation; cultures from the tissue were negative.

    2 reports: 2210968-2026-10552, 2210968-2026-10330

  • A published case report describes material from the hemostat left behind after an ovarian surgery, which was mistaken for a cyst on imaging and found months later during keyhole surgery. The patient recovered fully. A separate published report describes a flap surgery where the hemostatic dressing was used, with some cases showing persistent bleeding or symptoms.

    2 reports: 2210968-2026-09738, 2210968-2026-09741

  • One report describes a rash spreading from the knee to the ankle about one to ten days after knee replacement surgery, in a patient who was seen by a dermatologist. The report says the product was applied only to the joint capsule in this case.

    Report: 2210968-2026-09929

Written by AI from the narratives of the 16 newest reports that have one, received Sep 25, 2026 to Oct 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
51in the FDA’s Global Unique Device Identification Database
Establishment listings
32registered establishments that list this product code

Watch LMG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LMG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LMG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.