Product codes

FDA product code

ODE: Endoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd) (FDA product code)

Follow ODE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.1500
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
200 in the last 12 months
Median review time
65 daysthe latest 20 decisions
Recall records
40 in the last 12 months
Adverse event reports
24last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code ODE per year, by decision date, 20 since 2000. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20180
20190
20200
20210
20220
20230
20242
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K233240 GERDX-SystemG-Surg GmbH Jun 21, 2024267 days
K240879 EsophyX Z+ Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc. Apr 26, 202428 days
K172811 EsophyX Z, EsophyX2 HDEndogastric Solutions, Inc. Oct 19, 201731 days
K171307 EsophyX2 HD Device with SerosaFuse Fasteners and Accessories, EsophyX Z Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc. Jun 22, 201750 days
K160960 EsophyX® Z Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc. May 1, 201626 days
K151001 MUSE SystemMedigus , Ltd. Jun 5, 201551 days
K143645 EsophyX® Z Fastener Delivery DeviceEndogastric Solutions, Inc. Mar 4, 201572 days
K143634 MUSE SystemMedigus , Ltd. Jan 20, 201529 days
K142113 ESOPHYX2 HDEndogastric Solutions, Inc. Sep 30, 201457 days
K132151 SRS ENDOSCOPIC STAPLING SYSTEMMedigus , Ltd. Mar 19, 2014251 days

Recalls

Recall records for product code ODE per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 3 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20252
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1640-2025Class II Merit Medical Systems, Inc.Update to IFU to provide additional information related to risk with device over-rotation and multiple deployment of fasteners. Mar 14, 2025
Z-1641-2025Class II Merit Medical Systems, Inc.Update to IFU to provide additional information related to risk with device over-rotation and multiple deployment of fasteners. Mar 14, 2025
Z-1982-2013Class II Endogastric Solutions IncEndogastric Solutions, Inc. has received a limited number of reports relating to the loss of tissue mold control when operating the R2001 or R2002 EsophyX2 dev… Jun 6, 2013
Z-1136-2013Class II Endogastric Solutions IncEsophyX2Plus device was not validated under actual or simulated use conditions prior to distributing the product to physicians. Feb 4, 2013

Adverse event reports (MAUDE)

Medical device reports received per year that name product code ODE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201712
201811
201910
202018
202124
202216
202328
202441
202539
2026 (so far)22

Last 12 months by event type

  • Deaths0
  • Injuries19
  • Malfunctions5
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem16
  2. Detachment of Device or Device Component1
  3. Difficult to Remove1
  4. Entrapment of Device1
  5. Failure to Deliver1
  6. Patient Device Interaction Problem1

In plain English: what the newest reports describe Written by AI

  • Several reports describe bleeding and tears in the esophagus (the food pipe) linked to the procedure or the device. In one report a fastener site bled days after the procedure, and the patient needed a blood transfusion before the bleeding was found to have stopped on endoscopy.

    2 reports: 1721504-2026-00442, 1721504-2026-00236

  • Several reports describe a tear or laceration of the esophagus during the procedure. In one report the physician attributed a long lacerated tear to contact with the tip of the device, and in another a tear was closed with nine clips after the device's helical retractor was found bent.

    2 reports: 1721504-2026-00915, 1721504-2026-00365

  • Several reports describe the device's loading cords, helix lock or tissue mold not working as expected. A piece came off during loading, the helix unlocked several times, the mold did not straighten, and the cords had to be cut to remove the device, causing a significant delay.

    2 reports: 1721504-2026-00516, 50053877

  • One report describes the device's distal end or fastening parts causing trouble during procedures. In one report the device's distal tip broke off inside the stomach and was retrieved with a balloon sweep after snare and grasper attempts failed, and a replacement device had to be opened to finish the case.

    Report: 1721504-2026-00431

  • A report describes a device that was passed into the esophagus making an unusual gargling noise and leaking from the tissue mold, and the physician said it was not inflating well. The reporter believed this pointed to a possible defect in the device.

    Report: MW5184611

Written by AI from the narratives of the 19 newest reports that have one, received Mar 2, 2026 to Sep 25, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
14in the FDA’s Global Unique Device Identification Database
Establishment listings
17registered establishments that list this product code

Watch ODE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get ODE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in ODE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.