FDA product code
FEB: Accessories, Cleaning, For Endoscope (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.1500
- Review panel
- General Hospital
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Ineligible
- 510(k) and De Novo decisions
- 581 in the last 12 months
- Median review time
- 142 daysthe latest 25 decisions
- Recall records
- 4317 in the last 12 months
- Adverse event reports
- 382last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code FEB per year, by decision date, 58 since 1981. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 2 |
| 2018 | 1 |
| 2019 | 2 |
| 2020 | 2 |
| 2021 | 0 |
| 2022 | 1 |
| 2023 | 1 |
| 2024 | 2 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K261791 | MEDIVATORS™ ADVANTAGE NXT™ Automated Endoscope ReprocessorSteris | Oct 2, 2026126 days |
| K241168 | System 83 Revolve Endoscope Washer/DisinfectorWassenburg Medical, Inc. | Dec 19, 2024237 days |
| K243433 | enspire 3000 Cleaning and Liquid Chemical Sterilant Processing SystemSTERIS Corporation | Dec 2, 202427 days |
| K230930 | enspire 3000 Cleaning and Liquid Chemical Sterile Processing SystemSTERIS Corporation | Jun 30, 202388 days |
| K213833 | SCOPE BUDDY PLUS Endoscope Flushing AidMedivators, Inc. | Jan 14, 202236 days |
| K201920 | Endoscope Reprocessor OER-EliteOlympus Medical Systems Corp. | Sep 1, 202053 days |
| K173590 | System 83 Plus Washer/DisinfectorCustom Ultrasonics, Inc. | Mar 30, 2020860 days |
| K190969 | ENDOSCOPE REPROCESSOR OER-EliteOlympus Medical Systems Corp. | Jul 9, 201988 days |
| K181472 | AEROFLEX(TM) Automatic Endoscope Reprocessor with AUTOSURE(TM) MRC MonitorAdvanced Sterilization Products (Asp) | Apr 23, 2019323 days |
| K181865 | Acu-sInQ Complete Endoscope Cleaning Aid SystemSTERIS Corporation | Dec 14, 2018155 days |
Recalls
Recall records for product code FEB per year, by the date the recall began. Each recalled product is one record; these 43 records belong to 20 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 5 |
| 2024 | 5 |
| 2025 | 3 |
| 2026 (so far) | 17 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0154-2027Class II | Steris CorporationIf the vented cap becomes blocked, gas may accumulate and the bottle may swell due to increased internal pressure. In some cases, excess vapor or liquid chemis… | Sep 21, 2026 |
| Z-0155-2027Class II | Steris CorporationIf the vented cap becomes blocked, gas may accumulate and the bottle may swell due to increased internal pressure. In some cases, excess vapor or liquid chemis… | Sep 21, 2026 |
| Z-0156-2027Class II | Steris CorporationIf the vented cap becomes blocked, gas may accumulate and the bottle may swell due to increased internal pressure. In some cases, excess vapor or liquid chemis… | Sep 21, 2026 |
| Z-1898-2026Class II | Olympus Corporation of the AmericasPotential for the Version 2 reprocessor connecting tube lock levers may fail prematurely. | Mar 25, 2026 |
| Z-1899-2026Class II | Olympus Corporation of the AmericasPotential for the Version 2 reprocessor connecting tube lock levers may fail prematurely. | Mar 25, 2026 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code FEB. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 69 |
| 2018 | 88 |
| 2019 | 62 |
| 2020 | 426 |
| 2021 | 575 |
| 2022 | 607 |
| 2023 | 998 |
| 2024 | 884 |
| 2025 | 361 |
| 2026 (so far) | 365 |
Last 12 months by event type
- Deaths0
- Injuries16
- Malfunctions366
- Other or not stated0
Most reported device problems, last 12 months
- Device Reprocessing Problem80
- Filling Problem46
- Residue After Decontamination38
- Failure to Clean Adequately31
- Improper or Incorrect Procedure or Method29
- Break20
In plain English: what the newest reports describe Written by AI
Several reports describe debris or foreign material found inside the endoscope reprocessing machine, including black debris in the washing tank, debris clogging a disinfectant pump valve, debris on float and fluid sensors, and foreign material on basin sensors. None of these reports describe patient involvement.
4 reports: 9610595-2026-88008, 9610595-2026-87102, 9610595-2026-83855, 9610595-2026-83931
Several reports describe low flow or low pressure in the disinfectant or fluid lines of the reprocessing machine, found during troubleshooting. No patient involvement is described in these reports.
3 reports: 9610595-2026-87303, 9610595-2026-83938, 9610595-2026-84643
Several reports describe cleaning or disinfectant fluid not draining or filling slowly in the reprocessing machine's cleaning tub, with no error shown in one case. No patient involvement is described.
3 reports: 9610595-2026-87405, 9610595-2026-86992, 9610595-2026-87239
A report says a scope tested positive for unexpected contamination during a routine culture. A separate report describes a patient infection that led to a facility request for functional testing of a reprocessing machine. The reports do not link the two events.
2 reports: 9610595-2026-87983, 2150060-2026-00049
One report describes liquid dripping from a disinfectant bottle during replacement onto a worker's toes, causing a burn that the report says was severe, and the worker was treated at a hospital and was on medical leave. The facility asked for advice on foot protection because the manual did not mention it.
Report: 9610595-2026-84327
Written by AI from the narratives of the 18 newest reports that have one, received Oct 13, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 669in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 64registered establishments that list this product code
Other codes under 21 CFR 876.1500
Product codes classified under the same regulation.
Watch FEB in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get FEB every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FEB. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:FEBRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FEBRetrieved Nov 29, 2026, 2:33 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FEB · count decision_dateRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:FEBRetrieved Nov 29, 2026, 2:33 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FEB · count event_date_initiatedRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FEB · count res_event_numberRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0154-2027" "Z-0155-2027" "Z-0156-2027" "Z-1898-2026" "Z-1899-2026")Retrieved Nov 29, 2026, 2:33 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FEB AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 2:33 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FEB AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 2:33 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FEB AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 12:12 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:FEBRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:FEBRetrieved Nov 28, 2026, 8:34 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.1500Retrieved Nov 29, 2026, 8:27 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil