FDA product code
OCZ: Endoscopic Grasping/Cutting Instrument, Non-Powered (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.1500
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 741 in the last 12 months
- Median review time
- 80 daysthe latest 25 decisions
- Recall records
- 210 in the last 12 months
- Adverse event reports
- 27last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code OCZ per year, by decision date, 74 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252800 | KARL STORZ Endoscopic Accessories for UrologyKarl Storz SE & CO. KG | Jun 3, 2026273 days |
| K242923 | SimpleSnip Endoscopic Suture Cutter (SC500160, SC500230)Envision Endoscopy | Dec 20, 202487 days |
| K191900 | Single Use Grasping ForcepsZhejiang Chuangxiang Medical Technology Co., Ltd. | Mar 27, 2020255 days |
| K152802 | Grasping ForcepsMicro-Tech (Nanjing) Co., Ltd. | Jan 21, 2016115 days |
| K150939 | Ensizor Endoscopic ScissorsSlater Endoscopy, LLC | Jun 8, 201562 days |
| K141058 | ENSIZOR ENDOSCOPIC SCISSORSSlater Endoscopy, LLC | Aug 1, 201499 days |
| K133736 | ENDOSCOPIC SUTURE CUTTERUnited States Endoscopy Group, Inc. | Jan 7, 201429 days |
| K120084 | ENDOSCOPIC RETRIEVAL DEVICEUnited States Endoscopy Group, Inc. | May 30, 2012140 days |
| K103688 | G-PROX EZ ENDOSCOPIC GRASPERUsgi Medical | Jan 14, 201128 days |
| K101298 | ENDOCHOICE GRASPING INSULATED AND ALIGATOR JAW FORCEPS MODEL AMHGFA, ENDOCHOICE GRASPING INSULATED AND RAT TOOTH FORCEPSEndochoice, Inc. | Aug 5, 201087 days |
Recalls
Recall records for product code OCZ per year, by the date the recall began. Each recalled product is one record; these 21 records belong to 4 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 2 |
| 2022 | 18 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-0015-2023Class II | Hobbs Medical, Inc.Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9… | Jul 29, 2022 |
| Z-0016-2023Class II | Hobbs Medical, Inc.Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9… | Jul 29, 2022 |
| Z-0026-2023Class II | Hobbs Medical, Inc.Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9… | Jul 29, 2022 |
| Z-0027-2023Class II | Hobbs Medical, Inc.Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9… | Jul 29, 2022 |
| Z-0028-2023Class II | Hobbs Medical, Inc.Device label display an incorrect expiration date, extends the shelf life of the product. Affected product distributed in the United States from 3/25/2018 to 9… | Jul 29, 2022 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code OCZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 734 |
| 2018 | 252 |
| 2019 | 15 |
| 2020 | 21 |
| 2021 | 20 |
| 2022 | 33 |
| 2023 | 25 |
| 2024 | 37 |
| 2025 | 34 |
| 2026 (so far) | 25 |
Last 12 months by event type
- Deaths0
- Injuries4
- Malfunctions23
- Other or not stated0
Most reported device problems, last 12 months
- Break6
- Detachment of Device or Device Component3
- Device Contaminated at the User Facility2
- Device Reprocessing Problem2
- Difficult to Open or Close2
- Fracture2
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 474in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 88registered establishments that list this product code
Other codes under 21 CFR 876.1500
Product codes classified under the same regulation.
Watch OCZ in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get OCZ every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OCZ. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:OCZRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:OCZRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:OCZ · count decision_dateRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:OCZRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OCZ · count event_date_initiatedRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OCZ · count res_event_numberRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-0015-2023" "Z-0016-2023" "Z-0026-2023" "Z-0027-2023" "Z-0028-2023")Retrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OCZ AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OCZ AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:58 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OCZ AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:OCZRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:OCZRetrieved Nov 29, 2026, 12:08 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.1500Retrieved Nov 29, 2026, 8:27 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.