FDA product code
HXD: Clamp (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 878.4800
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 140 in the last 12 months
- Median review time
- 14 daysthe latest 14 decisions
- Recall records
- 40 in the last 12 months
510(k) and De Novo decisions
Decisions for product code HXD per year, by decision date, 14 since 1977. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K890371 | INTESTINAL CRUSHING CLAMPKinetic Medical Products | Feb 3, 198911 days |
| K890368 | KIDNEY CLAMPKinetic Medical Products | Feb 3, 198911 days |
| K890372 | INTESTINAL CLAMPKinetic Medical Products | Feb 3, 198911 days |
| K890381 | PARAMETRIUM CLAMPKinetic Medical Products | Feb 3, 198911 days |
| K874959 | VASCULAR CLAMPSolway, Inc. | Dec 30, 198728 days |
| K872386 | C CLAMPMed-Tool, Inc. | Jul 2, 198713 days |
| K863653 | SUCTION-OFFB&B Medical Technologies, Inc. | Oct 7, 198619 days |
| K853538 | CANNULA CLAMPCp Medical | Sep 12, 198520 days |
| K851654 | OMNIMED CLAMPOmni Intl., Inc. | May 31, 198539 days |
| K801819 | SURGICAL INSTRUMENTSRobert I. Chien & Assoc., Inc. | Aug 20, 198020 days |
Recalls
Recall records for product code HXD per year, by the date the recall began. Each recalled product is one record; these 4 records belong to 4 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 1 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 1 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1311-2025Class II | Aesculap IncThe forceps have been used in ways not covered by the design resulting in breakage of the clamps. | Jan 31, 2025 |
| Z-1440-2024Class II | MEDLINE INDUSTRIES, LP - NorthfieldProduct may have a weak seal which may result in a breach of sterility of the contents if the seal fails. The weak seal may not be detectable by all users. | Feb 23, 2024 |
| Z-2244-2018Class II | Stryker GmbHLaser etching which indicates whether the device is in compression or distraction mode appears to be on the wrong side of the lever arm | May 4, 2018 |
| Z-2316-2015Class II | Symmetry Surgical, Inc.Lack of sterility assurance. | Jun 16, 2015 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code HXD. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
This section didn’t load from openFDA. It’s retried within the hour.
Last 12 months by event type
This section didn’t load from openFDA. It’s retried within the hour.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 2,536in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 342registered establishments that list this product code
Other codes under 21 CFR 878.4800
Product codes classified under the same regulation.
Watch HXD in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get HXD every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HXD. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:HXDRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HXDRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HXD · count decision_dateRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:HXDRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HXD · count event_date_initiatedRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HXD · count res_event_numberRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1311-2025" "Z-1440-2024" "Z-2244-2018" "Z-2316-2015")Retrieved Nov 25, 2026, 10:14 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:HXDRetrieved Nov 25, 2026, 10:14 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:HXDRetrieved Nov 29, 2026, 7:09 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.4800Retrieved Nov 29, 2026, 6:19 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.