FDA product code

GDR: Saw, Manual And Accessories (FDA product code)

Follow GDR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 878.4800
Review panel
General and Plastic Surgery
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
20 in the last 12 months
Median review time
42 daysthe latest 2 decisions
Recall records
10 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code GDR per year, by decision date, 2 since 1985. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K874961 BONE CUTTING INSTRUMENTS & ACCESSORIESSolway, Inc. Dec 30, 198728 days
K851787 27-100 TO 29-130 VARIOUS BONE SAWS-CHARRIERE, SATTArtiberia Jun 20, 198556 days

Recalls

Recall records for product code GDR per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20171
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2252-2017Class II Argon Medical Devices, IncArgon Medical has received a complaint from one of their distributors of a potential packaging defect. The product is sealed in a pouch and the defect if prese… May 11, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GDR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20180
20190
20201
20211
20220
20230
20240
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions1
  • Other or not stated0

Most reported device problems, last 12 months

  1. Break1

In plain English: what the newest reports describe Written by AI

  • Two reports describe problems with the saw's cutting blades or wire-type parts during procedures. In one report, metal shavings were left in the wound after first use, which caused artifacts (false shapes or blurring) on a later exam. In another, a small metal fragment dropped from the saw into an open wound during a podiatric procedure, and the equipment was returned to the manufacturer for evaluation.

    2 reports: 2916714-2015-00651, 22406

  • In one report, the handle loop detached from one end of two instruments during a procedure, and the surgeon finished the procedure using two other instruments of the same type. The narrative says these instruments are replaced after each use.

    Report: 2916714-2015-00737

  • In one report, a jigsaw was used to remove the acetabulum (the hip socket) during a surgery, and afterward an MRI showed halation (an artifact, or false image distortion). The report states no patient complications resulted, and the manufacturer has not provided requested additional information.

    Report: 9610612-2021-00713

  • In one report, wires on the instrument snapped while the surgeon was removing the femoral component (the thigh-bone part) of a total hip. The surgeon said the instrument is designed to snap when friction is too high, as a safety mechanism. The report states no patient harm and no retained material.

    Report: MW5096157

Written by AI from the narratives of the 5 newest reports that have one, received May 11, 1995 to Nov 16, 2021. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
241in the FDA’s Global Unique Device Identification Database
Establishment listings
85registered establishments that list this product code

Watch GDR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GDR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GDR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.