Product codes

FDA product code

GAE: Snare, Surgical (FDA product code)

Follow GAE: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 878.4800
Review panel
General and Plastic Surgery
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
40 in the last 12 months
Median review time
113 daysthe latest 4 decisions
Recall records
30 in the last 12 months
Adverse event reports
4last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code GAE per year, by decision date, 4 since 1988. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K950776 BIPOLAR SNARECook Urological, Inc. Apr 18, 199556 days
K926036 ACUFEX SUTURE RETRIEVERAcufex Microsurgical, Inc. May 5, 1993155 days
K903174 ADVANCE SUTURE ABSORBABLE GUT SUTUREAdvance Suture, Inc. Jul 10, 1991357 days
K881224 ACUFEX SUTURE RETRIEVER, STERILE DISPOSABLEAcufex Microsurgical, Inc. Jun 1, 198871 days

Recalls

Recall records for product code GAE per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1624-2013Class II Surgical Instrument Service And Savings, Inc.The seal which maintains a sterile barrier for reprocessed medical devices became compromised to the point where product may fall out of the pouch. May 3, 2013
Z-1854-2008 Bard Peripheral Vascular IncThis action is being taken because the product has a potential for the handle to detach. The handle detachment may result in the device unable to retrieve the… May 9, 2008
Z-1855-2008 Bard Peripheral Vascular IncThis action is being taken because the product has a potential for the handle to detach. The handle detachment may result in the device unable to retrieve the… May 9, 2008

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GAE. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20178
20184
20195
20204
20211
20221
202312
202413
20259
2026 (so far)2

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions2
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Twisted/Bent2
  2. Defective Device1
  3. Material Deformation1

In plain English: what the newest reports describe Written by AI

  • Two reports describe lead extraction procedures in which a lead broke during snaring. One patient developed fluid around the heart that needed drainage and bypass, and the other had a hole in a major vein (superior vena cava perforation) that needed chest surgery. Both patients survived.

    2 reports: MW5182868, MW5168092

  • In two reports, the tip of the device was noticed to be defective during use. The device was removed from the patient and replaced with a working one.

    2 reports: 3004837686-2025-00013, MW5179696

  • One report describes a device that detached or came loose after polyp removal. The physician removed the loose piece from the patient, and the report says the patient did well and had no adverse effects.

    Report: 3004837686-2024-00009

  • A report says the protective sleeve at the tip of a suture device was damaged during surgery. The surgery was finished with a backup device, and the report states there was no delay and no further complications.

    Report: 1219602-2025-01537

Written by AI from the narratives of the 19 newest reports that have one, received Oct 23, 2024 to Feb 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
74in the FDA’s Global Unique Device Identification Database
Establishment listings
68registered establishments that list this product code

Watch GAE in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GAE every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GAE. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.