Product codes

FDA product code

GBZ: Catheter, Cholangiography (FDA product code)

Follow GBZ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 878.4200
Review panel
General and Plastic Surgery
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
240 in the last 12 months
Median review time
85 daysthe latest 24 decisions
Recall records
273 in the last 12 months
Adverse event reports
11last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code GBZ per year, by decision date, 24 since 1978. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K973621 PRE-VIEW CHOLANGIOGRAPHY CLAMPNashville Surgical Instruments Dec 17, 199785 days
K944790 FLEXIBLE LAPAROSCOPIC CHOLANGIOGRAPHY CATHETERApplied Medical Resources Nov 29, 199462 days
K942450 ENDOPATHEthicon Endo-Surgery, Inc. Aug 5, 199474 days
K932228 MICROVASIVE INSURG CHLOANGIOGRAPHIC CATHETERBoston Scientific Corp Aug 10, 199395 days
K926217 TERUMO ANGIOGRAPHIC CATHETER FOR LAPOROSCOPIC USETerumo Medical Corp. Jul 13, 1993215 days
K926143 ANGIOLAPCATH CHOLANGIOGRAPHY KITBd Becton Dickinson Vacutainer Systems Preanalytic Jul 7, 1993212 days
K924212 STRYKER ENDOSCOPY CHOLANGIOGRAM KITStryker Corp. Jul 7, 1993321 days
K925742 CLARUS CHOLANGIOGRAM CATHETER KITClarus Medical Systems, Inc. Jun 1, 1993200 days
K924981 OPERATIVE CHOLANGIOGRAM CATHETERTaut, Inc. Apr 6, 1993187 days
K924480 CHOLANGIOGRAPHY CLAMPApplied Medical Resources Mar 3, 1993181 days

Recalls

Recall records for product code GBZ per year, by the date the recall began. Each recalled product is one record; these 27 records belong to 11 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20172
20181
20190
20200
20210
20221
20231
20240
20250
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-3111-2026Class II Atrium Medical CorporationAn Out of Specification result (OOS) related to bacterial endotoxin testing in a single lot of catheters. Aug 7, 2026
Z-3112-2026Class II Atrium Medical CorporationAn Out of Specification result (OOS) related to bacterial endotoxin testing in a single lot of catheters. Aug 7, 2026
Z-3113-2026Class II Atrium Medical CorporationAn Out of Specification result (OOS) related to bacterial endotoxin testing in a single lot of catheters. Aug 7, 2026
Z-0484-2024Class II Atrium Medical CorporationA sterilization nonconformance prematurely aged the product, resulting in an inaccurate labeled expiration date. Sep 29, 2023
Z-1297-2022Class II Atrium Medical CorporationMismatch between the expiration date on the sterile barrier pouch and the expiration date on the case/shipper label. Product sterile barrier pouch label expira… Apr 21, 2022

Adverse event reports (MAUDE)

Medical device reports received per year that name product code GBZ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201721
201851
201912
202011
20217
20227
20235
20244
202512
2026 (so far)11

Last 12 months by event type

  • Deaths0
  • Injuries2
  • Malfunctions9
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem4
  2. No Apparent Adverse Event3
  3. Device Contamination with Chemical or Other Material2
  4. Difficult to Advance2
  5. Activation Failure1
  6. Break1

In plain English: what the newest reports describe Written by AI

  • The tip of a cholangiogram catheter, a thin tube used for X-rays of bile ducts, broke off in three reports. In two, it came off during removal and was caught on a grasper, and one says it could not be found. In the third, it broke during insertion and was removed.

    3 reports: 1820334-2026-00809, 50082356, 3009495876-2025-00001

  • Two reports describe infections after surgery with these catheters. One describes sepsis, a serious blood infection, in a child of unclear origin who may have had recalled product, not confirmed. The other describes surgical-site infections in patients with a straight catheter, and a recall was referenced.

    2 reports: 3011175548-2026-000013, 50461849

  • Two reports describe problems with sealed packaging. One found hair-like foreign matter inside sealed packaging, and the device was not used. The other found holes in the sterile packaging during inspection. Neither reports patient harm.

    2 reports: 1820334-2026-00367, 3011137372-2025-00289

  • One report describes a balloon catheter whose balloon would not inflate, and a second catheter from the same batch whose balloon burst during use. The patient was not harmed, and the reporter suspects a balloon defect, though this is not confirmed.

    Report: 3007208013-2025-00034

  • One report says a batch of chest tubes had oval rather than round tube ends. A scan showed a tube kinked where it entered the chest cavity, which blocked drainage, and the tube was removed as non-functional.

    Report: 3011175548-2025-000009

Written by AI from the narratives of the 12 newest reports that have one, received Jul 17, 2025 to Oct 15, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
148in the FDA’s Global Unique Device Identification Database
Establishment listings
61registered establishments that list this product code

Watch GBZ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get GBZ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GBZ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.