Product codes

FDA product code

FEQ: Pump, Air, Non-Manual, For Endoscope (FDA product code)

Follow FEQ: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.1500
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
210 in the last 12 months
Median review time
50 daysthe latest 21 decisions
Recall records
51 in the last 12 months
Adverse event reports
282last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FEQ per year, by decision date, 21 since 2000. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20182
20191
20200
20210
20221
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K220395 EndoGator Endoscopy Irrigation TubingSTERIS Corporation Mar 11, 202228 days
K191559 AquaShield System CO2, AquaShield System CO2-PENTAX, AquaShield System CO2-FUJIFILMUnited States Endoscopy Group, Inc. Aug 1, 201949 days
K182258 AquaShield System CO2; AquaShield System CO2 - PENTAX; AquaShield System CO2 - FujifilmUnited States Endoscopy Group, Inc. Sep 21, 201831 days
K173650 AquaShield System CO2- FujifilmUnited States Endoscopy Group, Inc. Jan 5, 201838 days
K163424 AquaShield System - PENTAX, AquaShield System CO2 - PENTAX, AquaShield System CO2 - FUJINONUnited State Endoscopy Group, Inc. Jan 4, 201729 days
K162152 Erbe’s CO2 Tubing/Cap SetsErbe USA, Inc. Aug 31, 201629 days
K161482 EndoChoice Water Bottle Cap Irrigation SystemEndochoice, Inc. Jun 27, 201627 days
K153588 EndoChoice Water Bottle Cap SystemEndochoice, Inc. Feb 24, 201670 days
K153362 AquaShield system CO2, AquaShield system-PENTAXUnited States Endoscopy Group, Inc. Dec 16, 201526 days
K142155 ENDOCHOICE WATER BOTTLE CAP SYSTEMEndochoice, Inc. Jan 20, 2015167 days

Recalls

Recall records for product code FEQ per year, by the date the recall began. Each recalled product is one record; these 5 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20241
20250
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-2062-2026Class II Erbe Medical, LLCDevices providing sterile water/CO2/air to endoscopes were manufactured with a distal irrigation segment connector configuration that may be more susceptible t… Mar 31, 2026
Z-0229-2025Class II Olympus Corporation of the AmericasDuring product testing, Olympus identified an intermittent loss of function of the OFP-2 Flushing Pump caused by an internal component connection failure. Aug 23, 2024
Z-0113-2016Class II Olympus Corporation of the Americassmall puncture marks in a sterile package for an accessory to an Olympus device Sep 11, 2015
Z-0329-2014Class II Olympus America Inc.There is a possibility that the pump head was not shipped in the locked position. If the pump head is in an unlocked position this may, under certain circumsta… May 20, 2013
Z-0806-2012 Olympus America Inc.Water may leak from the irrigation tubing used on the Olympus Flushing Pump Dec 12, 2011

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FEQ. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20174
201822
20196
20205
20213
202219
202311
2024705
2025344
2026 (so far)249

Last 12 months by event type

  • Deaths0
  • Injuries4
  • Malfunctions278
  • Other or not stated0

Most reported device problems, last 12 months

  1. Leak/Splash73
  2. Pumping Problem35
  3. Infusion or Flow Problem29
  4. Excess Flow or Over-Infusion12
  5. Improper Flow or Infusion12
  6. Break10

In plain English: what the newest reports describe Written by AI

  • Several reports describe the water flow or pressure behaving wrongly. Reports describe fluctuating water flow, abnormal pump head pressure, flow outside its specified range, a water jet out of control during maintenance, and backflow with a flow rate above the expected limit found during investigation.

    5 reports: 9611174-2026-00207, 9611174-2026-00208, 9611174-2026-00209, 9611174-2026-00228, 9611174-2026-00234

  • Several reports describe water leaking or flowing when it should not. One says water leaked during inspection before use, another says the pump constantly leaked with an amber warning light showing an internal fault, and one says fluid kept coming out of the scope after the foot pedal was released, starting after new tubing was installed.

    3 reports: 9611174-2026-00222, 9611174-2026-00215, 9611174-2026-00227

  • Several reports say the flow could not be controlled normally. Users could not adjust the pump speed or flow setting, and one had to run the pump with the foot pedal to change the flow rate.

    3 reports: 9611174-2026-00209, 9611174-2026-00219, 9611174-2026-00210

  • Several returned pumps were found with foreign material in the water bottle, including blue spots, black residue, and a brown and black substance. The reports do not say how this material got there or what effect it had on the device.

    3 reports: 9611174-2026-00232, 9611174-2026-00225, 9611174-2026-00205

  • One report describes a colonoscopy where the pump's clamp did not grip the tubing properly, so staff had to squeeze the assembly by hand to keep water flowing. The procedure was extended by less than thirty minutes and finished with the same device, and no patient harm was reported.

    Report: 9611174-2026-00231

Written by AI from the narratives of the 18 newest reports that have one, received Sep 17, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
143in the FDA’s Global Unique Device Identification Database
Establishment listings
78registered establishments that list this product code

Watch FEQ in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FEQ every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FEQ. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.