Product codes

FDA product code

FED: Endoscopic Access Overtube, Gastroenterology-Urology (FDA product code)

Follow FED: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.1500
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1056 in the last 12 months
Median review time
104 daysthe latest 25 decisions
Recall records
120 in the last 12 months
Adverse event reports
102last 12 months, 2 deaths

510(k) and De Novo decisions

Decisions for product code FED per year, by decision date, 105 since 1981. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20184
20195
20204
20213
20221
20233
20246
202511
2026 (so far)6

Latest decisions

NumberDevice and applicantDecision and review time
K260512 Disposable Ureteral Access SheathYangzhou Fartley Medical Instrument Technology Co., Ltd. Sep 21, 2026216 days
K262262 Pathfinder Endoscope OvertubeNeptune Medical, Inc. Sep 18, 202678 days
K260410 Single Use Ureteral Access SheathZhejiang Chuangxiang Medical Technology Co., Ltd. Sep 11, 2026214 days
K261915 Navigator™ Flex Ureteral Access Sheath SetBoston Scientific Corporation Aug 4, 202656 days
K260965 CVAC Aspiration SystemCalyxo, Inc. Apr 13, 202621 days
K260521 ClearEVAC Ureteral Aspirating Access Sheath (PUS-100-1040,PUS-100-1050, PUS-100-1240,PUS-100-1250)Zhuhai Pusen Medical Technology Co., Ltd. Apr 6, 202648 days
K252572 Prodeon Urethral Sheath SystemProdeon Medical, Inc. Oct 7, 202554 days
K250128 Single Use Suction-Evacuation Ureteral Access SheathAnhui Happiness Workshop Medical Instruments Co., Ltd. Sep 19, 2025245 days
K250132 Ureteral Access SheathZhejiang YiGao Medical Technology Co., Ltd. Sep 5, 2025231 days
K250695 Single-use Ureteral Access SheathShenzhen HugeMed Medical Technical Development Co., Ltd. Jul 8, 2025123 days

Recalls

Recall records for product code FED per year, by the date the recall began. Each recalled product is one record; these 12 records belong to 7 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20201
20211
20220
20230
20244
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1396-2025Class I Calyxo, Inc.Aspiration system, for endoscopic examination/treatment of urinary tract and kidney interior, to have labeling update adding additional instructions, for patie… Feb 19, 2025
Z-0713-2025Class I Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… Nov 27, 2024
Z-0714-2025Class I Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… Nov 27, 2024
Z-0715-2025Class I Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… Nov 27, 2024
Z-0716-2025Class I Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… Nov 27, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FED. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201732
201834
201930
202033
202155
202236
202353
202464
2025117
2026 (so far)87

Last 12 months by event type

  • Deaths2
  • Injuries39
  • Malfunctions61
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem28
  2. Material Split, Cut or Torn25
  3. Material Deformation21
  4. Peeled/Delaminated12
  5. Detachment of Device or Device Component8
  6. Break5

In plain English: what the newest reports describe Written by AI

  • In several reports, the ureter (the tube from kidney to bladder) was injured while a device was being pushed in, most often near the kidney junction. Doctors stopped the procedure and placed a stent, a temporary tube to help the ureter heal, usually for three to four weeks.

    6 reports: 3014683069-2026-00031, 3014683069-2026-00030, 3014683069-2026-00029, 3014683069-2026-00041, 2020550-2026-02173, 1820334-2026-00948

  • In four reports, the device's outer covering or shaft tore or broke, sometimes when it was being withdrawn from the sheath (a tube placed in the ureter to guide instruments). In two of these, the manufacturer's inspection found mechanical stresses during the procedure caused the damage, and the broken piece was removed with the device.

    4 reports: 3014683069-2026-00044, 3014683069-2026-00037, 3014683069-2026-00033, 3014683069-2026-00038

  • In three reports, damage was found on a sheath or dilator (the inserted tube that widens the path) when it was opened or used. The damage included a damaged tip, a crumbled and chipped sheath, and a kink. One report described a manufacturing defect where a slit in the dilator was too long, so the guidewire could exit it early.

    3 reports: 2124215-2026-50383, 2124215-2026-50060, 9610711-2026-00262

  • In three reports, patients had bleeding or a blood clot around the kidney after the procedure. Some needed a blood transfusion, a procedure to block bleeding, or a hospital stay. In one report, the physician could not confirm the cause but considered a laser-related injury more likely.

    3 reports: 3014683069-2026-00043, 3014683069-2026-00039, 3014683069-2026-00034

  • In one report, the laser used to break up stones burned off the soft tip of a suction sheath while it was pinned against the kidney. A thin inner layer of the sheath also partly peeled away.

    Report: 3005580113-2026-00042

Written by AI from the narratives of the 19 newest reports that have one, received Aug 13, 2026 to Oct 16, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
716in the FDA’s Global Unique Device Identification Database
Establishment listings
186registered establishments that list this product code

Watch FED in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FED every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FED. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.