FDA product code
FED: Endoscopic Access Overtube, Gastroenterology-Urology (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 876.1500
- Review panel
- Gastroenterology and Urology
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 1056 in the last 12 months
- Median review time
- 104 daysthe latest 25 decisions
- Recall records
- 120 in the last 12 months
- Adverse event reports
- 102last 12 months, 2 deaths
510(k) and De Novo decisions
Decisions for product code FED per year, by decision date, 105 since 1981. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 1 |
| 2018 | 4 |
| 2019 | 5 |
| 2020 | 4 |
| 2021 | 3 |
| 2022 | 1 |
| 2023 | 3 |
| 2024 | 6 |
| 2025 | 11 |
| 2026 (so far) | 6 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260512 | Disposable Ureteral Access SheathYangzhou Fartley Medical Instrument Technology Co., Ltd. | Sep 21, 2026216 days |
| K262262 | Pathfinder Endoscope OvertubeNeptune Medical, Inc. | Sep 18, 202678 days |
| K260410 | Single Use Ureteral Access SheathZhejiang Chuangxiang Medical Technology Co., Ltd. | Sep 11, 2026214 days |
| K261915 | Navigator™ Flex Ureteral Access Sheath SetBoston Scientific Corporation | Aug 4, 202656 days |
| K260965 | CVAC Aspiration SystemCalyxo, Inc. | Apr 13, 202621 days |
| K260521 | ClearEVAC Ureteral Aspirating Access Sheath (PUS-100-1040,PUS-100-1050, PUS-100-1240,PUS-100-1250)Zhuhai Pusen Medical Technology Co., Ltd. | Apr 6, 202648 days |
| K252572 | Prodeon Urethral Sheath SystemProdeon Medical, Inc. | Oct 7, 202554 days |
| K250128 | Single Use Suction-Evacuation Ureteral Access SheathAnhui Happiness Workshop Medical Instruments Co., Ltd. | Sep 19, 2025245 days |
| K250132 | Ureteral Access SheathZhejiang YiGao Medical Technology Co., Ltd. | Sep 5, 2025231 days |
| K250695 | Single-use Ureteral Access SheathShenzhen HugeMed Medical Technical Development Co., Ltd. | Jul 8, 2025123 days |
Recalls
Recall records for product code FED per year, by the date the recall began. Each recalled product is one record; these 12 records belong to 7 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 4 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1396-2025Class I | Calyxo, Inc.Aspiration system, for endoscopic examination/treatment of urinary tract and kidney interior, to have labeling update adding additional instructions, for patie… | Feb 19, 2025 |
| Z-0713-2025Class I | Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… | Nov 27, 2024 |
| Z-0714-2025Class I | Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… | Nov 27, 2024 |
| Z-0715-2025Class I | Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… | Nov 27, 2024 |
| Z-0716-2025Class I | Trokamed GmbHIf the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly b… | Nov 27, 2024 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code FED. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 32 |
| 2018 | 34 |
| 2019 | 30 |
| 2020 | 33 |
| 2021 | 55 |
| 2022 | 36 |
| 2023 | 53 |
| 2024 | 64 |
| 2025 | 117 |
| 2026 (so far) | 87 |
Last 12 months by event type
- Deaths2
- Injuries39
- Malfunctions61
- Other or not stated0
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem28
- Material Split, Cut or Torn25
- Material Deformation21
- Peeled/Delaminated12
- Detachment of Device or Device Component8
- Break5
In plain English: what the newest reports describe Written by AI
In several reports, the ureter (the tube from kidney to bladder) was injured while a device was being pushed in, most often near the kidney junction. Doctors stopped the procedure and placed a stent, a temporary tube to help the ureter heal, usually for three to four weeks.
6 reports: 3014683069-2026-00031, 3014683069-2026-00030, 3014683069-2026-00029, 3014683069-2026-00041, 2020550-2026-02173, 1820334-2026-00948
In four reports, the device's outer covering or shaft tore or broke, sometimes when it was being withdrawn from the sheath (a tube placed in the ureter to guide instruments). In two of these, the manufacturer's inspection found mechanical stresses during the procedure caused the damage, and the broken piece was removed with the device.
4 reports: 3014683069-2026-00044, 3014683069-2026-00037, 3014683069-2026-00033, 3014683069-2026-00038
In three reports, damage was found on a sheath or dilator (the inserted tube that widens the path) when it was opened or used. The damage included a damaged tip, a crumbled and chipped sheath, and a kink. One report described a manufacturing defect where a slit in the dilator was too long, so the guidewire could exit it early.
3 reports: 2124215-2026-50383, 2124215-2026-50060, 9610711-2026-00262
In three reports, patients had bleeding or a blood clot around the kidney after the procedure. Some needed a blood transfusion, a procedure to block bleeding, or a hospital stay. In one report, the physician could not confirm the cause but considered a laser-related injury more likely.
3 reports: 3014683069-2026-00043, 3014683069-2026-00039, 3014683069-2026-00034
In one report, the laser used to break up stones burned off the soft tip of a suction sheath while it was pinned against the kidney. A thin inner layer of the sheath also partly peeled away.
Report: 3005580113-2026-00042
Written by AI from the narratives of the 19 newest reports that have one, received Aug 13, 2026 to Oct 16, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 716in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 186registered establishments that list this product code
Other codes under 21 CFR 876.1500
Product codes classified under the same regulation.
Watch FED in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get FED every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FED. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:FEDRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FEDRetrieved Nov 29, 2026, 4:22 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:FED · count decision_dateRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:FEDRetrieved Nov 29, 2026, 4:22 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FED · count event_date_initiatedRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:FED · count res_event_numberRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1396-2025" "Z-0713-2025" "Z-0714-2025" "Z-0715-2025" "Z-0716-2025")Retrieved Nov 29, 2026, 4:22 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FED AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:22 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FED AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:22 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:FED AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 3:17 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:FEDRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:FEDRetrieved Nov 28, 2026, 8:28 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:876.1500Retrieved Nov 29, 2026, 8:27 AM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil