FDA device news · Product code DXN
FDA 510(k) clearance
BP1000 Ultra-Compact Fingertip Blood Pressure Monitor (BP1000) (K253152): Biozen, LLC 510(k) clearance
Oklahoma City, OK
- Decision
- Substantially Equivalent
- Decision date
- May 6, 2026
- Received
- Sep 26, 2025
- 510(k) type
- Traditional
- Product code
- DXNSystem, Measurement, Blood-Pressure, Non-Invasive
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.1130
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 222 daysreceipt to decision, calendar days
- Median in DXN
- 141 daysthe latest 24 other decisions
- DXN decisions
- 31in the last 12 months
- Applicant’s 510(k)s
- 1in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The BP1000 Ultra-Compact Fingertip Blood Pressure Monitor is a portable, non-invasive device that estimates systolic and diastolic blood pressure in adults. It uses optical sensors (light-based sensors that detect blood flow changes in the finger), a pressure sensor, a temperature sensor, and an accelerometer, and shows results through a connected mobile app.
- What it’s cleared for
- The BP1000 is cleared as a digital monitor for spot check measurements of blood pressure in adults ages 22-59 who do not have active arrhythmias (such as atrial fibrillation), peripheral artery disease, or pregnancy. It is intended for use at home.
- Compared with (the predicate)
- K222658, Accurate 24 Non-invasive blood pressure monitor
- How it differs
- The BP1000 measures at the finger, while the Accurate 24 measures at the wrist. The BP1000 presses the finger linearly against the device, while the Accurate 24 uses a clamp around the wrist. The BP1000 uses oscillometry, while the Accurate 24 uses pulse wave transit time calculations.
- Testing the summary lists
- Electrical safety and electromagnetic compatibility (IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11, IEC TS 60601-4-2)
- Blood pressure accuracy clinical study (ISO 81060-2), with confounding studies for skin tone and BMI
- Human factors and usability (IEC 62366-1, two-step OTC self-selection and performance testing)
- Software lifecycle (ISO 62304) and risk management (ISO 14971)
- Biocompatibility risk evaluation (ANSI/AAMI/ISO 10993-1), optical safety (IEC 62471), and wireless coexistence (USEMCSC C63.27)
- Bench testing for low perfusion error detection and Bluetooth packet drop robustness
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253152 took 222 calendar days from receipt to decision. Of the latest 24 other decisions in product code DXN, 8 took longer, 16 were faster; their median was 141 days.
Latest decisions in DXN
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260670 | YUWELL® Electronic Blood Pressure MonitorJiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Traditional | Oct 28, 2026240 days |
| K260470 | Electronic Blood Pressure Monitor (BP-204C, BP-204A, BP-215, BP-203C, BP-205A, BP-201C, BP-217, BP-202C, BP-202 BP-205, BP-205B,BP-206)Shenzhen Brav Electronic Technologies Co., Ltd. · Traditional | Oct 1, 2026231 days |
| K261929 | Upper Arm Blood pressure monitor (BP7155D)OMRON Healthcare, Inc. · Special | Sep 10, 202693 days |
| K254000 | Happy Health Blood Pressure MonitorHappy Health, Inc. · Traditional | Sep 3, 2026262 days |
| K262658 | Automatic Digital Blood Pressure monitor (LD-526)Honsun (Nantong) Co., Ltd. · Special | Aug 31, 202632 days |
| K261394 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6186 Plus, DBP-6286B Plus, DBP-61E3 Plus, DBP-61E2 Plus, DBP-62E3B Plus, DBP-62E2B Plus)JOYTECH Healthcare Co., Ltd. · Traditional | Aug 26, 2026119 days |
| K253425 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6194-P,DBP-6294B-P,DBP-6195P,DBP-6295B-P, DBP-6196P,DBP-6296B-P,DBP-61E1-P, DBP-62E1B-P,DBP-62E3B-P,DBP-61E2-P,DBP-62E2B-P,DBP-61E3-P,DBP-6173-P,DBP-6273B-P,DBP-6179-P,DBP-6279B-P)Joytech Healthcare Co. , Ltd. · Traditional | Aug 13, 2026316 days |
| K261061 | BP Go (BPP-855)Wellvii, Inc. · Traditional | Aug 13, 2026135 days |
| K261082 | Microlife Wrist Blood Pressure Monitor , (Model BPHJG5-G)Microlife Corporation · Traditional | Jul 23, 2026113 days |
| K261136 | Blood Pressure Monitor (M501,M501A,M502,M502A,M502C,M502D)Guangzhou Daxin Health Technology Co., Ltd. · Traditional | Jul 23, 2026107 days |
Other 510(k)s from Biozen, LLC
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
This is the only 510(k) in openFDA under this applicant name.
Watch DXN in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get DXN every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DXN. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253152Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXN AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Biozen, LLC"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil