FDA device news · Product code DXN
FDA 510(k) clearance
Happy Health Blood Pressure Monitor (K254000): Happy Health, Inc. 510(k) clearance
Austin, TX
- Decision
- Substantially Equivalent
- Decision date
- Sep 3, 2026
- Received
- Dec 15, 2025
- 510(k) type
- Traditional
- Product code
- DXNSystem, Measurement, Blood-Pressure, Non-Invasive
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.1130
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 262 daysreceipt to decision, calendar days
- Median in DXN
- 141 daysthe latest 24 other decisions
- DXN decisions
- 31in the last 12 months
- Applicant’s 510(k)s
- 3in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The Happy Health Blood Pressure Monitor is a software as a medical device (SaMD), meaning software that performs a medical function without being part of a physical device. It estimates systolic (top number) and diastolic (bottom number) blood pressure in mmHg using physiological signals such as PPG (a light-based pulse signal), EDA (skin electrical activity), accelerometry (motion) and skin temperature.
- What it’s cleared for
- The device is cleared to take spot-check measurements of systolic and diastolic blood pressure in adults aged 22 to 50 who need non-invasive blood pressure monitoring, in a home or clinical setting. It is for measurement and display only and makes no diagnosis. It should not be used by people with arrhythmias such as atrial fibrillation, severe vascular disease, radial-artery abnormalities (such as Raynaud's syndrome), people taking vasoactive drugs, or people who are pregnant.
- Compared with (the predicate)
- K250415, G0 Blood Pressure Monitoring System
- How it differs
- The summary says the device uses multiple sensors (PPG, EDA, accelerometer and skin temperature) and a finger location, while the predicate uses a PPG pressure sensor at the wrist. The device does not need cuff calibration every 24 hours, which the predicate requires. The predicate is for ages 22 to 59 and the device is for ages 22 to 50.
- Testing the summary lists
- Software verification and validation (FDA software guidance, IEC 62304)
- Cybersecurity (FDA cybersecurity guidance)
- Risk management (ISO 14971)
- Usability (FDA human factors guidance)
- Clinical validation against invasive arterial line measurements in 85 subjects, 850 determinations (ISO 81060-2:2018+A1+A2, IEEE 1708a-2019)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K254000 took 262 calendar days from receipt to decision. Of the latest 24 other decisions in product code DXN, 4 took longer, 20 were faster; their median was 141 days.
Latest decisions in DXN
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260670 | YUWELL® Electronic Blood Pressure MonitorJiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Traditional | Oct 28, 2026240 days |
| K260470 | Electronic Blood Pressure Monitor (BP-204C, BP-204A, BP-215, BP-203C, BP-205A, BP-201C, BP-217, BP-202C, BP-202 BP-205, BP-205B,BP-206)Shenzhen Brav Electronic Technologies Co., Ltd. · Traditional | Oct 1, 2026231 days |
| K261929 | Upper Arm Blood pressure monitor (BP7155D)OMRON Healthcare, Inc. · Special | Sep 10, 202693 days |
| K254000 | Happy Health Blood Pressure MonitorHappy Health, Inc. · Traditional | Sep 3, 2026262 days |
| K262658 | Automatic Digital Blood Pressure monitor (LD-526)Honsun (Nantong) Co., Ltd. · Special | Aug 31, 202632 days |
| K261394 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6186 Plus, DBP-6286B Plus, DBP-61E3 Plus, DBP-61E2 Plus, DBP-62E3B Plus, DBP-62E2B Plus)JOYTECH Healthcare Co., Ltd. · Traditional | Aug 26, 2026119 days |
| K253425 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6194-P,DBP-6294B-P,DBP-6195P,DBP-6295B-P, DBP-6196P,DBP-6296B-P,DBP-61E1-P, DBP-62E1B-P,DBP-62E3B-P,DBP-61E2-P,DBP-62E2B-P,DBP-61E3-P,DBP-6173-P,DBP-6273B-P,DBP-6179-P,DBP-6279B-P)Joytech Healthcare Co. , Ltd. · Traditional | Aug 13, 2026316 days |
| K261061 | BP Go (BPP-855)Wellvii, Inc. · Traditional | Aug 13, 2026135 days |
| K261082 | Microlife Wrist Blood Pressure Monitor , (Model BPHJG5-G)Microlife Corporation · Traditional | Jul 23, 2026113 days |
| K261136 | Blood Pressure Monitor (M501,M501A,M502,M502A,M502C,M502D)Guangzhou Daxin Health Technology Co., Ltd. · Traditional | Jul 23, 2026107 days |
Other 510(k)s from Happy Health, Inc.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
Watch DXN in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get DXN every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DXN. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K254000Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXN AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Happy Health, Inc."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.