Wrist Blood Pressure Monitor (BPM-W1VL) (K253133): Shenzhen Imdk Medical Technology Co., Ltd. 510(k) clearance
Shenzhen, CN
- Decision
- Substantially Equivalent
- Decision date
- Feb 13, 2026
- Received
- Sep 25, 2025
- 510(k) type
- Traditional
- Product code
- DXNSystem, Measurement, Blood-Pressure, Non-Invasive
- Review panel
- Cardiovascular
- Device class
- Class II
- Regulation
- 21 CFR 870.1130
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 141 daysreceipt to decision, calendar days
- Median in DXN
- 147 daysthe latest 25 other decisions
- DXN decisions
- 31in the last 12 months
- Applicant’s 510(k)s
- 7in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The Wrist Blood Pressure Monitor, model BPM-W1VL, is a portable, battery or AC-powered device that measures blood pressure and pulse rate at the wrist. It inflates a cuff around the wrist and uses the oscillometric method, which senses small vibrations in the artery as the cuff deflates to find the systolic (top) and diastolic (bottom) pressures and the pulse rate. It stores measurements in memory for later review.
- What it’s cleared for
- It is cleared to measure systolic and diastolic blood pressure and pulse rate in people older than twelve years, at home or in medical facilities. The intended wrist circumference is 13.5 to 21.5 cm. The summary also lists contraindications, including use with newborns, infants, children, pregnant patients, patients with preeclampsia, diabetes, severe heart or kidney disease, atrial fibrillation, and upper limb trauma.
- Compared with (the predicate)
- K231310, Electronic Blood Pressure Monitor (Model HWA10, submitted by Shenzhen Jumper Medical Equipment Co., Ltd)
- How it differs
- The summary says the device differs from the predicate HWA10 in several areas. These include patient population (older than twelve years versus adults), memory size, blood pressure measurement range, pulse range, operating and storage environment, dimensions, and weight.
- Testing the summary lists
- Electrical safety (ANSI AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012, A2:2010/(R)2012, AMD2:2021)
- Electromagnetic compatibility (IEC 60601-1-2:2014+AMD1:2020)
- Home healthcare environment requirements (IEC 60601-1-11:2015/2020)
- Particular safety requirements for automated non-invasive sphygmomanometers (IEC 80601-2-30 Edition 2.0, 2018-03)
- Clinical performance of automated blood pressure measurement (ISO 81060-2, third edition 2018-11, Amendment 1 2020-01)
- Biocompatibility (ISO 10993-1; cytotoxicity, sensitization, and intracutaneous reactivity)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K253133 took 141 calendar days from receipt to decision. Of the latest 25 other decisions in product code DXN, 13 took longer, 12 were faster; their median was 147 days.
Latest decisions in DXN
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260670 | YUWELL® Electronic Blood Pressure MonitorJiangsu Yuyue Medical Equipment & Supply Co., Ltd. · Traditional | Oct 28, 2026240 days |
| K260470 | Electronic Blood Pressure Monitor (BP-204C, BP-204A, BP-215, BP-203C, BP-205A, BP-201C, BP-217, BP-202C, BP-202 BP-205, BP-205B,BP-206)Shenzhen Brav Electronic Technologies Co., Ltd. · Traditional | Oct 1, 2026231 days |
| K261929 | Upper Arm Blood pressure monitor (BP7155D)OMRON Healthcare, Inc. · Special | Sep 10, 202693 days |
| K254000 | Happy Health Blood Pressure MonitorHappy Health, Inc. · Traditional | Sep 3, 2026262 days |
| K262658 | Automatic Digital Blood Pressure monitor (LD-526)Honsun (Nantong) Co., Ltd. · Special | Aug 31, 202632 days |
| K261394 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6186 Plus, DBP-6286B Plus, DBP-61E3 Plus, DBP-61E2 Plus, DBP-62E3B Plus, DBP-62E2B Plus)JOYTECH Healthcare Co., Ltd. · Traditional | Aug 26, 2026119 days |
| K253425 | Arm-type Fully Automatic Digital Blood Pressure Monitor (DBP-6194-P,DBP-6294B-P,DBP-6195P,DBP-6295B-P, DBP-6196P,DBP-6296B-P,DBP-61E1-P, DBP-62E1B-P,DBP-62E3B-P,DBP-61E2-P,DBP-62E2B-P,DBP-61E3-P,DBP-6173-P,DBP-6273B-P,DBP-6179-P,DBP-6279B-P)Joytech Healthcare Co. , Ltd. · Traditional | Aug 13, 2026316 days |
| K261061 | BP Go (BPP-855)Wellvii, Inc. · Traditional | Aug 13, 2026135 days |
| K261082 | Microlife Wrist Blood Pressure Monitor , (Model BPHJG5-G)Microlife Corporation · Traditional | Jul 23, 2026113 days |
| K261136 | Blood Pressure Monitor (M501,M501A,M502,M502A,M502C,M502D)Guangzhou Daxin Health Technology Co., Ltd. · Traditional | Jul 23, 2026107 days |
Other 510(k)s from Shenzhen Imdk Medical Technology Co., Ltd.
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K252655 | Pulse Oximeter (PO-A2AO, PO-A2AT, PO-A3AO, PO-H1AO, PO-B1AO, PO-C5AO, PO-C5AT, PO-C6AO, PO-C6AT)Shenzhen Imdk Medical Technology Co., Ltd. · Traditional | May 11, 2026262 days |
| K243118 | Arm Blood Pressure Monitor (model: BPM-A7VL)Shenzhen Imdk Medical Technology Co., Ltd. · Traditional | Nov 26, 202457 days |
| K233040 | EMS/TENS Massager DeviceShenzhen Imdk Medical Technology Co., Ltd. · Traditional | Feb 12, 2024140 days |
| K221979 | Pulse Oximeter (Model C101A2, C101B1, C101A3)Shenzhen Imdk Medical Technology Co., Ltd. · Special | Oct 16, 2022103 days |
| K173123 | Pulse OximeterShenzhen Imdk Medical Technology Co., Ltd. · Traditional | Aug 13, 2018318 days |
| K180419 | Ultrasonic Doppler (Model YM-2T8)Shenzhen Imdk Medical Technology Co., Ltd. · Traditional | Jul 19, 2018154 days |
Watch DXN in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get DXN every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in DXN. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K253133Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:DXNRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:DXN AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Shenzhen Imdk Medical Technology Co., Ltd."Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil