PYX: Temporary Non-Roller Type Right Heart Support Blood Pump (FDA product code)

Follow PYX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class III
Regulation
21 CFR 870.4360
Review panel
Cardiovascular
Premarket route
PMA
Implant
No
Life-sustaining or supporting
Yes
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Ineligible
PMA decisions
631 original PMA, the rest supplements
Median review time
30 daysthe latest 25 decisions
Recall records
73 in the last 12 months
Adverse event reports
555last 12 months, 152 deaths

PMA decisions

Original PMAs and supplements for product code PYX per year, by decision date, 63 since 2017. Review time is the days from receipt to decision.

All of them in the FDA’s PMA database

PMA decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20187
201910
20208
20218
202213
20234
20241
20257
2026 (so far)3

Latest decisions

NumberDevice and applicantDecision and review time
P170011 S064 Impella RP Flex with SmartAssistAbiomed, Inc. Oct 26, 202628 days
P170011 S063 Impella RP SystemAbiomed, Inc. Apr 1, 202630 days
P170011 S061 Impella RP System, Impella RP with Smart Assist System, Impella RP Flex SystemAbiomed, Inc. Feb 6, 2026106 days
P170011 S062 Impella CP with SmartAssist; Impella 5.5 with SmartAssistAbiomed, Inc. Dec 19, 202530 days
P170011 S060 Impella RP, Impella RP with SmartAssist, Impella RP Flex with SmartAssistAbiomed, Inc. Sep 19, 202528 days
P170011 S058 Purge CassetteAbiomed, Inc. Sep 15, 2025123 days
P170011 S056 Impella RP System; Impella RP with SmartAssist System; Impella RP Flex with SmartAssist SystemAbiomed, Inc. Aug 1, 2025175 days
P170011 S059 Impella RP, Impella RP with SmartAssist, and Impella RP Flex with SmartAssistAbiomed, Inc. Jul 25, 202528 days
P170011 S057 Impella RP, Impella RP with SmartAssist, and Impella RP Flex with SmartAssistAbiomed, Inc. Jun 23, 202588 days
P170011 S055 Impella RP with SmartAssist, Impella RP Flex with SmartAssistAbiomed, Inc. Jan 10, 202522 days

Recalls

Recall records for product code PYX per year, by the date the recall began. Each recalled product is one record; these 7 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20232
20242
20250
2026 (so far)3

Latest recalls

Recall and classFirm and reasonBegan
Z-1469-2026Class I Abiomed, Inc.Differential pressure (dP) sensor in Impella RP devices may malfunction, causing sensor values to drift. Jan 27, 2026
Z-1470-2026Class I Abiomed, Inc.Differential pressure (dP) sensor in Impella RP devices may malfunction, causing sensor values to drift. Jan 27, 2026
Z-1471-2026Class I Abiomed, Inc.Differential pressure (dP) sensor in Impella RP devices may malfunction, causing sensor values to drift. Jan 27, 2026
Z-0829-2025Class I Abiomed, Inc.Optical Sensors have been damaged due to physical interaction between the inlet and another device resulting in a Placement Signal Not Reliable (PSNR) alarm an… Dec 12, 2024
Z-0830-2025Class I Abiomed, Inc.Optical Sensors have been damaged due to physical interaction between the inlet and another device resulting in a Placement Signal Not Reliable (PSNR) alarm an… Dec 12, 2024

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PYX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
201810
201910
202010
20217
20229
202390
20241,031
2025550
2026 (so far)515

Last 12 months by event type

  • Deaths152
  • Injuries244
  • Malfunctions159
  • Other or not stated0

Most reported device problems, last 12 months

  1. Device Sensing Problem189
  2. Patient Device Interaction Problem125
  3. Adverse Event Without Identified Device or Use Problem118
  4. Restricted Flow rate110
  5. Increase in Pressure54
  6. Malposition of Device37

In plain English: what the newest reports describe Written by AI

  • Two reports describe pump flow dropping after the patient was moved or coughed while on a ventilator. One reports a fall from 3.9 to the mid-2 liters per minute range, with lung artery pressure rising from the 20s to the 60s mmHg. The other reports a fall from 3.0 to 1.3 liters per minute.

    2 reports: 1220648-2026-14058, 1220648-2026-13974

  • Two reports describe bleeding at the insertion site. In one, the site oozed, blood thinners were held and a unit of blood was given, but it was not reported whether bleeding stopped. In the other, the sheath was accidentally tugged during transfer, and manual pressure was applied.

    2 reports: 1220648-2026-13974, 1220648-2026-13821

  • Two reports describe high purge pressure alarms, followed by purge system blocked alarms, on the pump's fluid line. In one, replacing the purge cassette, a removable part, did not stop the alarms, and no kinks were seen in the line.

    2 reports: 1220648-2026-13828, 1220648-2026-13769

  • Two reports describe a 'placement signal not reliable' alarm the day after implant, meaning the system could not confirm the pump's position. In one, the controller kept showing flow and support was not interrupted. In the other, imaging confirmed the pump was correctly positioned.

    2 reports: 1220648-2026-13663, 1220648-2026-13491

  • One report describes signs of hemolysis, meaning red blood cells breaking down, on the day of implant. These included discolored urine and hemolyzed lab samples, and plasma free hemoglobin testing was not performed.

    Report: 1220648-2026-13895

Written by AI from the narratives of the 12 newest reports that have one, received Sep 30, 2026 to Oct 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
9in the FDA’s Global Unique Device Identification Database
Establishment listings
2registered establishments that list this product code

Product codes classified under the same regulation.

Watch PYX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PYX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PYX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.