Product codes

FDA product code

KFM: Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type (FDA product code)

Follow KFM: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 870.4360
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
840 in the last 12 months
Median review time
82 daysthe latest 25 decisions
Recall records
400 in the last 12 months
Adverse event reports
244last 12 months, 7 deaths

510(k) and De Novo decisions

Decisions for product code KFM per year, by decision date, 84 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20193
20203
20213
20220
20233
20240
20252
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K251762 Quantum Perfusion Centrifugal Blood Pump CP20NG with Integrated Sensors (CP20V-NG)Spectrum Medical S.R.L. Aug 4, 202556 days
K250326 Quantum Perfusion Centrifugal Blood Pump CP22NG with Integrated Sensors (CP22V-NG)Spectrum Medical S.R.L. Jun 24, 2025139 days
K233091 Quantum Perfusion Centrifugal Blood Pump CP37 with Integrated Sensors (CP37V-VT); Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors (CP22V-VT)Qura S.R.L Oct 26, 202330 days
K232132 LifeSPARC SystemCardiacassist, Inc. Aug 3, 202316 days
K220842 Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors, Quantum Perfusion Centrifugal Blood Pump CP20 with Integrated SensorsQura S.R.L May 19, 2023422 days
K200091 Capiox iCP Centrifugal PumpTerumo Cardiovascular Systems Corporation Nov 18, 2021672 days
K201320 Quantum PureFlow Centrifugal Blood Pump CP22 with Integrated SensorQura S.R.L Nov 3, 2021534 days
K193663 FloPump 57mL Centrifugal PumpInternational Biophysics Corporation Mar 10, 2021435 days
K202169 Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22Qura S.R.L Sep 2, 202030 days
K201068 Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortiva BioActive SurfaceMedtronic, Inc. May 21, 202029 days

Recalls

Recall records for product code KFM per year, by the date the recall began. Each recalled product is one record; these 40 records belong to 23 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20181
20193
20209
20211
20220
20231
20242
20251
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1327-2025Class II Spectrum Medical IncTheir is a potential of fluid leakage from the centrifugal blood pump pump during the priming procedure or during clinical procedures. Jan 16, 2025
Z-0977-2024Class II Maquet Medical Systems USANonconformities at their seal could potentially compromise the sterile barrier for affected products. Breach of sterile barrier could expose patients to pathog… Jan 8, 2024
Z-0978-2024Class II Maquet Medical Systems USANonconformities at their seal could potentially compromise the sterile barrier for affected products. Breach of sterile barrier could expose patients to pathog… Jan 8, 2024
Z-2465-2023Class II Cardiac Assist, IncEpoxy used during manufacturing of the LifeSPARC Pump may have uncured epoxy. if undetectable curing may result in added risk of early pump failure, Jun 30, 2023
Z-2277-2021Class II QURA S.R.L.Product labeled as sterile may not have been adequately sterilized. In addition, these devices were imported to the US distributor, but the devices are not 510… Mar 22, 2021

Adverse event reports (MAUDE)

Medical device reports received per year that name product code KFM. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017121
2018176
2019311
2020437
2021446
2022294
2023346
2024296
2025251
2026 (so far)218

Last 12 months by event type

  • Deaths7
  • Injuries30
  • Malfunctions207
  • Other or not stated0

Most reported device problems, last 12 months

  1. Electrical /Electronic Property Problem77
  2. Pumping Stopped47
  3. Insufficient Device Problem Information35
  4. Battery Problem21
  5. Mechanical Problem17
  6. Adverse Event Without Identified Device or Use Problem13

In plain English: what the newest reports describe Written by AI

  • Several reports describe the RotaFlow console showing a "Head error" message, either at startup, during routine testing, or during preventive maintenance. No patient was involved in these events, and the reports say the error could lead to an unintended pump stop during treatment.

    4 reports: 8010762-2026-0000680, 8010762-2026-0000597, 8010762-2026-0000574, 8010762-2026-0000567

  • Several reports describe the console's low battery warning appearing during patient treatment, and in one, the device was swapped out for another unit. In one report a patient on ECMO (a machine that does the work of the heart and lungs) was moved for a CT scan when the low battery alarm shut the console down, and staff turned the pump by hand until it was recharged.

    4 reports: 8010762-2026-0000618, 8010762-2026-0000640, 8010762-2026-0000605, 8010762-2026-0000597

  • Several reports describe the console showing a message during surgery or treatment, and the device was then replaced or restarted. The reports say no harm to patients was recorded, but the reports note that swapping a device interrupts treatment briefly.

    4 reports: 8010762-2026-0000683, 8010762-2026-0000653, 8010762-2026-0000649, 8010762-2026-0000609

  • One report describes the pump head in the disposable pack being cracked, which led to blood leaking. The manufacturer's report lists two possible lot numbers, and the patient had no blood loss and the device was replaced to finish the procedure.

    Report: 9617601-2026-06140

  • One report describes the pump producing much less flow than expected at startup, about 200 to 300 mL/min instead of roughly 1 L/min at normal speeds. The operator had to run the pump about 1.5 times faster to reach the target flow, and no patient harm was reported.

    Report: 9681834-2026-00233

Written by AI from the narratives of the 16 newest reports that have one, received Sep 18, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
1,812in the FDA’s Global Unique Device Identification Database
Establishment listings
113registered establishments that list this product code

Product codes classified under the same regulation.

Watch KFM in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get KFM every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KFM. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.