FDA product code
KFM: Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 870.4360
- Review panel
- Cardiovascular
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 840 in the last 12 months
- Median review time
- 82 daysthe latest 25 decisions
- Recall records
- 400 in the last 12 months
- Adverse event reports
- 244last 12 months, 7 deaths
510(k) and De Novo decisions
Decisions for product code KFM per year, by decision date, 84 since 1977. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 1 |
| 2018 | 0 |
| 2019 | 3 |
| 2020 | 3 |
| 2021 | 3 |
| 2022 | 0 |
| 2023 | 3 |
| 2024 | 0 |
| 2025 | 2 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K251762 | Quantum Perfusion Centrifugal Blood Pump CP20NG with Integrated Sensors (CP20V-NG)Spectrum Medical S.R.L. | Aug 4, 202556 days |
| K250326 | Quantum Perfusion Centrifugal Blood Pump CP22NG with Integrated Sensors (CP22V-NG)Spectrum Medical S.R.L. | Jun 24, 2025139 days |
| K233091 | Quantum Perfusion Centrifugal Blood Pump CP37 with Integrated Sensors (CP37V-VT); Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors (CP22V-VT)Qura S.R.L | Oct 26, 202330 days |
| K232132 | LifeSPARC SystemCardiacassist, Inc. | Aug 3, 202316 days |
| K220842 | Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors, Quantum Perfusion Centrifugal Blood Pump CP20 with Integrated SensorsQura S.R.L | May 19, 2023422 days |
| K200091 | Capiox iCP Centrifugal PumpTerumo Cardiovascular Systems Corporation | Nov 18, 2021672 days |
| K201320 | Quantum PureFlow Centrifugal Blood Pump CP22 with Integrated SensorQura S.R.L | Nov 3, 2021534 days |
| K193663 | FloPump 57mL Centrifugal PumpInternational Biophysics Corporation | Mar 10, 2021435 days |
| K202169 | Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22Qura S.R.L | Sep 2, 202030 days |
| K201068 | Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortiva BioActive SurfaceMedtronic, Inc. | May 21, 202029 days |
Recalls
Recall records for product code KFM per year, by the date the recall began. Each recalled product is one record; these 40 records belong to 23 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 1 |
| 2019 | 3 |
| 2020 | 9 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 1 |
| 2024 | 2 |
| 2025 | 1 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1327-2025Class II | Spectrum Medical IncTheir is a potential of fluid leakage from the centrifugal blood pump pump during the priming procedure or during clinical procedures. | Jan 16, 2025 |
| Z-0977-2024Class II | Maquet Medical Systems USANonconformities at their seal could potentially compromise the sterile barrier for affected products. Breach of sterile barrier could expose patients to pathog… | Jan 8, 2024 |
| Z-0978-2024Class II | Maquet Medical Systems USANonconformities at their seal could potentially compromise the sterile barrier for affected products. Breach of sterile barrier could expose patients to pathog… | Jan 8, 2024 |
| Z-2465-2023Class II | Cardiac Assist, IncEpoxy used during manufacturing of the LifeSPARC Pump may have uncured epoxy. if undetectable curing may result in added risk of early pump failure, | Jun 30, 2023 |
| Z-2277-2021Class II | QURA S.R.L.Product labeled as sterile may not have been adequately sterilized. In addition, these devices were imported to the US distributor, but the devices are not 510… | Mar 22, 2021 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code KFM. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 121 |
| 2018 | 176 |
| 2019 | 311 |
| 2020 | 437 |
| 2021 | 446 |
| 2022 | 294 |
| 2023 | 346 |
| 2024 | 296 |
| 2025 | 251 |
| 2026 (so far) | 218 |
Last 12 months by event type
- Deaths7
- Injuries30
- Malfunctions207
- Other or not stated0
Most reported device problems, last 12 months
- Electrical /Electronic Property Problem77
- Pumping Stopped47
- Insufficient Device Problem Information35
- Battery Problem21
- Mechanical Problem17
- Adverse Event Without Identified Device or Use Problem13
In plain English: what the newest reports describe Written by AI
Several reports describe the RotaFlow console showing a "Head error" message, either at startup, during routine testing, or during preventive maintenance. No patient was involved in these events, and the reports say the error could lead to an unintended pump stop during treatment.
4 reports: 8010762-2026-0000680, 8010762-2026-0000597, 8010762-2026-0000574, 8010762-2026-0000567
Several reports describe the console's low battery warning appearing during patient treatment, and in one, the device was swapped out for another unit. In one report a patient on ECMO (a machine that does the work of the heart and lungs) was moved for a CT scan when the low battery alarm shut the console down, and staff turned the pump by hand until it was recharged.
4 reports: 8010762-2026-0000618, 8010762-2026-0000640, 8010762-2026-0000605, 8010762-2026-0000597
Several reports describe the console showing a message during surgery or treatment, and the device was then replaced or restarted. The reports say no harm to patients was recorded, but the reports note that swapping a device interrupts treatment briefly.
4 reports: 8010762-2026-0000683, 8010762-2026-0000653, 8010762-2026-0000649, 8010762-2026-0000609
One report describes the pump head in the disposable pack being cracked, which led to blood leaking. The manufacturer's report lists two possible lot numbers, and the patient had no blood loss and the device was replaced to finish the procedure.
Report: 9617601-2026-06140
One report describes the pump producing much less flow than expected at startup, about 200 to 300 mL/min instead of roughly 1 L/min at normal speeds. The operator had to run the pump about 1.5 times faster to reach the target flow, and no patient harm was reported.
Report: 9681834-2026-00233
Written by AI from the narratives of the 16 newest reports that have one, received Sep 18, 2026 to Oct 30, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 1,812in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 113registered establishments that list this product code
Other codes under 21 CFR 870.4360
Product codes classified under the same regulation.
Watch KFM in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get KFM every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in KFM. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:KFMRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KFMRetrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:KFM · count decision_dateRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:KFMRetrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KFM · count event_date_initiatedRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:KFM · count res_event_numberRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1327-2025" "Z-0977-2024" "Z-0978-2024" "Z-2465-2023" "Z-2277-2021")Retrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KFM AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KFM AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:KFM AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 5:01 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:KFMRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:KFMRetrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:870.4360Retrieved Nov 28, 2026, 7:04 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil