Product codes

FDA product code

PBY: Temporary Tissue Marker (FDA product code)

Follow PBY: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4300
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
70 in the last 12 months
Median review time
135 daysthe latest 7 decisions
Recall records
00 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code PBY per year, by decision date, 7 since 2013. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20180
20190
20200
20211
20221
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K223682 Sirius Pintuition Seed, Sirius Pintuition Probe, Sirius Pintuition Base UnitSirius Medical Systems B.V. Nov 9, 2023336 days
K222643 Sirius Pintuition Seed, Sirius Pintuition Probe, Sirius Pintuition Base UnitSirius Medical Systems B.V. Oct 19, 202248 days
K200734 Sirius Pintuition Seed, Sirius Pintuition Probe, Sirius Pintuition Base UnitSirius Medical Systems B.V. Feb 24, 2021341 days
K163667 RFID Localization System- Localizer Reader, RFID Localization System- Localizer Surgical Probe, RFID Localization System- Localizer Surgical Probe (5 pack), RFID Localization System- Tag Applicator, RFID Localization System -Tag Applicator (10 pack)Health Beacons, Inc. Apr 28, 2017122 days
K163541 Magseed Magnetic Marker SystemEndomagnetics Ltd., Jan 13, 201728 days
K153044 Sentimag System, Sentimark Magnetic Marker SystermEndomagnetics Ltd., Mar 2, 2016135 days
K120804 CIANNA MEDICAL TISSUE MARKER AND DELIVERY SYSTEMCianna Medical Feb 4, 2013325 days

Recalls

Recall records for product code PBY per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code PBY. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20171
20180
20191
20200
20210
20220
20231
20241
20251
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Material Fragmentation1

In plain English: what the newest reports describe Written by AI

  • One report says a marker's glass casing broke as it was released from its applicator in a dense breast, leaving glass fragments behind. The marker then stopped sending its signal. It was removed with the tissue, and a follow-up mammogram was clear.

    Report: 3013649990-2019-00001

  • One report says white threads at the tip of a probe came off during a procedure and went into the patient. The threads were removed before the incision was closed. No further information was available.

    Report: 1222780-2026-00157

  • One report describes a surgical probe that gave unreliable readings, jumping between low and high numbers when placed near a marker, so the surgeon said it was not reading correctly. Switching to a different device resolved the problem.

    Report: 22152472

  • One report from the UK says metal surgical forceps caused a false signal in the detector used to find a seed during lymph node removal, meaning the detector reacted to the forceps. Plastic retractors were used instead. The report says there was no patient harm.

    Report: 3020733550-2023-00001

  • One report says a reflector tumor marker failed after it was removed from a patient. A company representative said the reflector system is deactivated when touched by a bovie, an electrosurgical cutting tool. The manufacturer wants to examine the device.

    Report: MW5073437

Written by AI from the narratives of the 6 newest reports that have one, received Nov 20, 2017 to Apr 8, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
18in the FDA’s Global Unique Device Identification Database
Establishment listings
6registered establishments that list this product code

Watch PBY in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get PBY every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in PBY. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.