Product codes

FDA product code

MVR: Device, Anastomotic, Microvascular (FDA product code)

Follow MVR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4300
Review panel
General and Plastic Surgery
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
90 in the last 12 months
Median review time
61 daysthe latest 9 decisions
Recall records
60 in the last 12 months

510(k) and De Novo decisions

Decisions for product code MVR per year, by decision date, 9 since 1986. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20192
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K190499 Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc. Sep 6, 2019189 days
K191252 Gem FlowCoupler SystemBaxter/ Synovis Micro Companies Alliance, Inc. Jul 9, 201961 days
K143589 GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc. Jan 16, 201529 days
K142309 GEM Flow COUPLER Device and SystemSynovis Life Technologies, Inc. Sep 16, 201428 days
K132727 GEM FLOW COUPLER DEVICE AND SYSTEMSynovis Life Technologies, Inc. Oct 22, 201349 days
K093310 GEM FLOW COUPLER DEVICE AND SYSTEMSynovis Micro Companies Alliance, Inc. Feb 1, 2010102 days
K090679 VESSELINK MICROVASCULAR ANASTOMOTIC COUPLER SYSTEMVioptix, Inc. Apr 17, 200932 days
K040163 MICROVASCULAR ANASTOMOTIC DEVICESynovis Micro Companies Alliance, Inc. Apr 16, 200481 days
K861985 3M BRAND MICROVASCULAR ANASTOMOTIC COUPLER (27XX)3M Company Dec 4, 1986196 days

Recalls

Recall records for product code MVR per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 4 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20205
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0939-2021Class II Baxter Healthcare CorporationPotential for the battery to lose its ability to be recharged. Dec 28, 2020
Z-2474-2020Class II Baxter Healthcare CorporationA firmware issue may cause the GEM1020M-2 Flow Coupler Monitor to intermittently shut down when a WiFi connection is not established. Jun 2, 2020
Z-1685-2020Class II Baxter Healthcare CorporationThe Coupler size labeling of the outer tray may not match the Couper size labeling of the inner tray in the GEM Microvascular Coupler Device Mar 5, 2020
Z-1686-2020Class II Baxter Healthcare CorporationThe Coupler size labeling of the outer tray may not match the Couper size labeling of the inner tray in the GEM Microvascular Coupler Device Mar 5, 2020
Z-1687-2020Class II Baxter Healthcare CorporationThe Coupler size labeling of the outer tray may not match the Couper size labeling of the inner tray in the GEM Microvascular Coupler Device Mar 5, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code MVR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

This section didn’t load from openFDA. It’s retried within the hour.

Last 12 months by event type

This section didn’t load from openFDA. It’s retried within the hour.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
20in the FDA’s Global Unique Device Identification Database
Establishment listings
20registered establishments that list this product code

Watch MVR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get MVR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in MVR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.