FDA product code
OYK: Ankle Arthroplasty Implantation System (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 888.3110
- Review panel
- Orthopedic
- Premarket route
- 510(k)
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 70 in the last 12 months
- Median review time
- 112 daysthe latest 7 decisions
- Recall records
- 21 in the last 12 months
- Adverse event reports
- 2last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code OYK per year, by decision date, 7 since 2020. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 1 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 2 |
| 2024 | 4 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K243173 | Salto Talaris Ankle PSI System3D Systems, Inc. | Oct 25, 202425 days |
| K243174 | Cadence Ankle PSI System3D Systems, Inc. | Oct 25, 202425 days |
| K241326 | Cadence Ankle PSI System3D Systems, Inc. | Aug 30, 2024112 days |
| K241148 | Salto Talaris Ankle PSI System3D Systems, Inc. | Aug 30, 2024127 days |
| K231585 | Vantage PSI System3D Systems, Inc. | Jun 30, 202330 days |
| K223326 | Axiom PSR SystemRestor3D | Mar 30, 2023150 days |
| K193432 | Vantage PSI System3D Systems | Nov 9, 2020335 days |
Recalls
Recall records for product code OYK per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 1 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-3178-2026Class II | restor3d Inc.Ankle implantation systems were packaged with incorrect patient-specific cutting guides, which may result in: delayed surgery, the need to use standard instrum… | Jul 27, 2026 |
| Z-1144-2012 | Integra LifeSciences Corp.During 6/30/2010 to 8/17/2011 the firm received five (5) incident complaints of breakage of the threaded part of the compression guide which potentially occurr… | Nov 17, 2011 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code OYK. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 4 |
| 2022 | 0 |
| 2023 | 1 |
| 2024 | 2 |
| 2025 | 2 |
| 2026 (so far) | 2 |
Last 12 months by event type
- Deaths0
- Injuries1
- Malfunctions1
- Other or not stated0
Most reported device problems, last 12 months
- Loosening of Implant Not Related to Bone-Ingrowth1
- Wrong Label1
In plain English: what the newest reports describe Written by AI
Two reports describe excessive wear of the plastic liner (inlay) that sits between joint parts, plus bone cysts (fluid-filled holes) in the shin and talus bones. One of these patients was revised about three years and seven months after surgery.
2 reports: 1038671-2025-02029, 1038671-2024-00196
Two reports describe a tibial component (the metal part fixed in the shin bone) that appeared to sink or move, and both patients needed revision surgery. One report also describes cyst-like areas around the implant stem.
2 reports: 3014833750-2026-00017, 1038671-2025-02029
One report describes a plastic liner (poly) found fractured on a routine X-ray, although the patient had no symptoms. The patient was scheduled for a poly exchange, meaning replacement of the liner.
Report: 1038671-2025-02355
One report says packaging for liners was missing an oxidation barrier (a protective layer), which could possibly damage them if stored over five years. The manufacturer filed the report as a precaution and said no such liners stored that long were implanted in Germany.
Report: 1038671-2024-00196
One report describes cutting guides packed inside the package that belonged to a different case, although the correct anatomic model was received. The surgery was completed successfully and the patient was not affected.
Report: 3014833750-2026-00026
Written by AI from the narratives of the 10 newest reports that have one, received Feb 22, 2021 to Jul 16, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 33in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 32registered establishments that list this product code
Other codes under 21 CFR 888.3110
Product codes classified under the same regulation.
Watch OYK in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get OYK every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OYK. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:OYKRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:OYKRetrieved Nov 29, 2026, 11:53 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:OYK · count decision_dateRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:OYKRetrieved Nov 29, 2026, 11:53 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OYK · count event_date_initiatedRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:OYK · count res_event_numberRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-3178-2026" "Z-1144-2012")Retrieved Nov 29, 2026, 11:53 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OYK AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OYK AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:OYK AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 12:48 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:OYKRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:OYKRetrieved Nov 29, 2026, 4:28 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:888.3110Retrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil