FDA product code
HSN: Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class II
- Regulation
- 21 CFR 888.3110
- Review panel
- Orthopedic
- Premarket route
- 510(k)
- Implant
- Yes
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 692 in the last 12 months
- Median review time
- 115 daysthe latest 25 decisions
- Recall records
- 470 in the last 12 months
- Adverse event reports
- 1,575last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code HSN per year, by decision date, 69 since 1976. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 4 |
| 2018 | 4 |
| 2019 | 2 |
| 2020 | 6 |
| 2021 | 4 |
| 2022 | 1 |
| 2023 | 6 |
| 2024 | 7 |
| 2025 | 3 |
| 2026 (so far) | 2 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K261120 | APEX 3D S Diamond TibiaParagon 28, Inc. | Oct 7, 2026187 days |
| K253159 | Prophecy Incompass Surgical Planning SystemWright Medical Technology, Inc. (Stryker) | Jun 16, 2026263 days |
| K252454 | Kinos Total Ankle SystemRestor3D | Sep 3, 202530 days |
| K250037 | Incompass Total Ankle SystemWright Medical Technology, Inc. (Stryker) | Jun 20, 2025163 days |
| K250641 | APEX 3D Total Ankle Replacement SystemParagon 28, Inc. | May 1, 202558 days |
| K240475 | Hintermann Series H2 Total Ankle SystemVilex, LLC | Dec 2, 2024286 days |
| K241999 | Prophecy Surgical Planning SystemWright Medical Technology, Inc. (Stryker) | Nov 1, 2024115 days |
| K242868 | Kinos Total Ankle SystemRestor3D | Oct 18, 202428 days |
| K241482 | Kinos Total Ankle SystemRestor3D | Jul 22, 202459 days |
| K240259 | APEX 3D Total Ankle Replacement SystemParagon 28, Inc. | Jun 24, 2024145 days |
Recalls
Recall records for product code HSN per year, by the date the recall began. Each recalled product is one record; these 47 records belong to 17 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 3 |
| 2018 | 0 |
| 2019 | 27 |
| 2020 | 2 |
| 2021 | 3 |
| 2022 | 3 |
| 2023 | 2 |
| 2024 | 1 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1477-2024Class II | Wright Medical Technology, Inc.Stryker has identified an issue that impacts specific lots of Infinity" Resection Guide Adjustment Blocks. The parts within these three lots were found to have… | Mar 6, 2024 |
| Z-0587-2024Class II | Exactech, Inc.Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag. | Nov 21, 2023 |
| Z-2105-2023Class II | Wright Medical Technology, Inc.The devices were manufactured with the pin sleeve holes too narrow, which does not allow the pin sleeves to pass through the pin sleeve holes, thereby preventi… | Jun 13, 2023 |
| Z-0139-2023Class II | Wright Medical Technology, Inc.The tibial tray lock detail is oversized (larger than specification). | Sep 30, 2022 |
| Z-0140-2023Class II | Wright Medical Technology, Inc.The tibial tray lock detail is oversized (larger than specification). | Sep 30, 2022 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code HSN. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 96 |
| 2018 | 185 |
| 2019 | 277 |
| 2020 | 281 |
| 2021 | 237 |
| 2022 | 453 |
| 2023 | 796 |
| 2024 | 1,095 |
| 2025 | 1,664 |
| 2026 (so far) | 1,189 |
Last 12 months by event type
- Deaths0
- Injuries1,544
- Malfunctions31
- Other or not stated0
Most reported device problems, last 12 months
- Adverse Event Without Identified Device or Use Problem757
- Insufficient Device Problem Information424
- Osseointegration Problem197
- Loss of Osseointegration138
- Implant subsidence56
- Fracture44
In plain English: what the newest reports describe Written by AI
Several reports describe a CT scan, sent to the manufacturer's digital planning team, suggesting a patient may need revision surgery, with no reason given in the report. In one of these, a surgeon also reported high uptake under the component on a SPECT scan, a nuclear imaging test that can signal bone or tissue activity around an implant.
9 reports: 3010667733-2026-01420, 3010667733-2026-01421, 3010667733-2026-01422, 3010667733-2026-01419, 3010667733-2026-01414, 3010667733-2026-01412, 3010667733-2026-01393, 3010667733-2026-01395, 3010667733-2026-01397
Several reports describe loosening of the tibia component, the metal shin piece that anchors the ankle replacement to the shinbone. One report says it could not be determined whether the loosening was caused by the device or by the patient's bone quality.
3 reports: 3010667733-2026-01393, 3010667733-2026-01395, 3008650117-2026-00545
Reports describe the patient developing an infection after ankle replacement, requiring a washout, a procedure that flushes out the joint. One report says the components were found loose and removed, and that the plastic dome showed delamination, meaning its layers separated.
2 reports: 3008650117-2026-00545, 1038671-2026-01395
One report describes the tibial plate collapsing into a sideways tilt, called varus, causing ongoing pain. The patient needed revision surgery and received a different manufacturer's ankle replacement.
Report: 1038671-2026-01397
One report describes a planned plastic insert exchange after an infection that could not go ahead because the needed instruments and implants were not available in the area. The report says the patient was last known to be stable.
Report: 1038671-2026-01395
Written by AI from the narratives of the 14 newest reports that have one, received Oct 26, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 4,536in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 269registered establishments that list this product code
Other codes under 21 CFR 888.3110
Product codes classified under the same regulation.
Watch HSN in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get HSN every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in HSN. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:HSNRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HSNRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:HSN · count decision_dateRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:HSNRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HSN · count event_date_initiatedRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:HSN · count res_event_numberRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1477-2024" "Z-0587-2024" "Z-2105-2023" "Z-0139-2023" "Z-0140-2023")Retrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HSN AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HSN AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:HSN AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:HSNRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:HSNRetrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:888.3110Retrieved Nov 29, 2026, 4:16 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil