Product codes

FDA product code

OUR: Sacroiliac Joint Fixation (FDA product code)

Follow OUR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 888.3040
Review panel
Orthopedic
Premarket route
510(k)
Implant
Yes
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
1347 in the last 12 months
Median review time
91 daysthe latest 25 decisions
Recall records
21 in the last 12 months
Adverse event reports
17last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OUR per year, by decision date, 134 since 2005. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20174
20187
20197
20207
20219
202214
202320
202415
202514
2026 (so far)7

Latest decisions

NumberDevice and applicantDecision and review time
K260712 VySion™ SI SystemVy Spine, LLC Nov 10, 2026250 days
K262522 Odys-SI ScrewMedyssey Co, Ltd. Oct 15, 202685 days
K261381 TiLink-L™ SI Joint Fusion SystemSurGenTec, LLC Aug 24, 2026119 days
K260477 CATAMARAN™ SI Joint Fusion SystemTenon Medical Apr 8, 202655 days
K253488 iFuse INTRA Ti™ Implant SystemSI-BONE, Inc. Feb 11, 2026110 days
K253611 Falco Fusion SystemMcnicoll Surgical, Inc. Jan 29, 202672 days
K252834 Sacroiliac Joint Truss System (SJTS)4Web Medical Jan 28, 2026145 days
K251365 OptumSI Implant SystemSi Solutions, LLC Nov 20, 2025203 days
K252322 SIros-X SystemGenesys Spine Oct 22, 202589 days
K253094 iFuse Bedrock Granite Implant SystemSI-BONE, Inc. Oct 9, 202516 days

Recalls

Recall records for product code OUR per year, by the date the recall began. Each recalled product is one record; these 2 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20251
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-0146-2027Class II SI-BONE, Inc.The pelvic fixation screws failed to meet acceptance criteria for tube packaging seal integrity testing; therefore, sterility assurance cannot be ensured. Aug 21, 2026
Z-0894-2026Class III Orthofix U.S. LLCLabeling contains claims that are not consistently present. Nov 3, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OUR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017157
2018137
2019175
2020148
2021154
202223
20237
202415
202510
2026 (so far)17

Last 12 months by event type

  • Deaths0
  • Injuries11
  • Malfunctions6
  • Other or not stated0

Most reported device problems, last 12 months

  1. Detachment of Device or Device Component5
  2. Mechanical Problem4
  3. Fracture3
  4. Adverse Event Without Identified Device or Use Problem2
  5. Break1
  6. Difficult to Insert1

In plain English: what the newest reports describe Written by AI

  • Several reports describe significant bleeding during or after the procedure. In some cases the bleeding was hard to control, a pseudoaneurysm (a bulge in an artery) was found, and blood transfusion or emergency artery treatment was needed.

    4 reports: 3008455034-2025-00002, 3007700286-2025-00004, 3007700286-2025-00002, 3007700286-2025-00001

  • Driver or inserter tips broke or sheared off during placement of the implant in several reports. Fragments may have stayed in the patient, and one report notes a possible MRI safety concern with retained stainless-steel fragments.

    3 reports: 3005977257-2026-00002, 3004499989-2026-00033, 3004499989-2026-00032

  • Some reports describe the fixation not healing or the implant causing ongoing pain. In one case a CT scan showed the joint had not fused, and in another a surgeon said removal might not help because the joint was fused.

    2 reports: 3008455034-2026-00001, 3004142400-2026-00086

  • In one report, the surgeon could not tighten the nut onto the screw, and attempts to tighten it pushed the screw forward. The implant was left in place, and the patient later had nerve irritation that was linked to the implant advancing toward a nerve, and surgery to remove it.

    Report: 3009704301-2026-00001

  • In one report, a deep infection developed after implantation. During removal, the surgeon could not grip the implant with the adjustment or removal tools, so it was pushed into the pelvis and removed through an open surgery from the front.

    Report: 3007700286-2026-00001

Written by AI from the narratives of the 20 newest reports that have one, received Mar 20, 2025 to Sep 4, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
7,424in the FDA’s Global Unique Device Identification Database
Establishment listings
341registered establishments that list this product code

Watch OUR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OUR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OUR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.