Product codes

FDA product code

OCL: Surgical Device, For Cutting, Coagulation, And/Or Ablation Of Tissue, Including Cardiac Tissue (FDA product code)

Follow OCL: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 878.4400
Review panel
Cardiovascular
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
540 in the last 12 months
Median review time
89 daysthe latest 25 decisions
Recall records
170 in the last 12 months
Adverse event reports
45last 12 months, 2 deaths

510(k) and De Novo decisions

Decisions for product code OCL per year, by decision date, 54 since 1997. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20182
20196
20201
20212
20222
20230
20241
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K252056 Isolator® Synergy™ EnCompass Clamp and Guide system (OLH, OSH, GPM100)AtriCure, Inc. Jul 24, 202523 days
K234151 Isolator Synergy EnCapture Ablation System (EMH)AtriCure, Inc. Aug 27, 2024242 days
K221358 Isolator® Linear Pen (MLP1); Isolator® Transpolar™ Pen (MAX1, MAX5), Coolrail® Linear Pen (MCR1); Isolator® Synergy Surgical Ablation System (EMR2, EML2); Isolator® Synergy™ EnCompass Clamp (OLH, OSH) and Guide System; Isolator® Synergy Access Clamp (EMT1)AtriCure, Inc. Dec 30, 2022233 days
K223508 Cardioblate Gemini-s 49260 Surgical Ablation Device; Cardioblate Gemini-s 49351 Surgical Ablation DeviceMedtronic, Inc. Dec 22, 202230 days
K210477 AtriCure Isolator Encompass Ablation System, GLIDEPATH Magnetic GUIDEAtriCure, Inc. Jul 26, 2021157 days
K211311 AtriCure Isolator® Synergy™ Surgical Ablation SystemAtriCure, Inc. May 28, 202128 days
K200514 Cardioblate Gemini-s Surgical Ablation DeviceMedtronic Jun 3, 202093 days
K193162 EPi-Sense Guided Coagulation System with VisiTraxAtriCure, Inc. Dec 13, 201928 days
K192125 Isolator Transpolar Pen, Isolator Long Pen TT, Isolator Linear PenAtriCure, Inc. Nov 4, 201990 days
K191526 Cardioblate CryoFlex Surgical Ablation SystemMedtronic, Inc. Oct 1, 2019113 days

Recalls

Recall records for product code OCL per year, by the date the recall began. Each recalled product is one record; these 17 records belong to 10 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20195
20204
20211
20221
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1131-2022Class II Medtronic Perfusion SystemsFirm detected an increase in complaints related to fractured jaw tips of the Cardioblate Gemini-s. Apr 20, 2022
Z-0273-2022Class II Medtronic Perfusion SystemsThere is potential for intermittent electrical connectivity between the console and probe. Sep 27, 2021
Z-0493-2021Class II MEDTRONIC ATS MEDICAL, INC.There is a potential defect in the seals of the sterile barrier pouch used to package the CryoFlex disposables devices Oct 12, 2020
Z-0494-2021Class II MEDTRONIC ATS MEDICAL, INC.There is a potential defect in the seals of the sterile barrier pouch used to package the CryoFlex disposables devices Oct 12, 2020
Z-0495-2021Class II MEDTRONIC ATS MEDICAL, INC.There is a potential defect in the seals of the sterile barrier pouch used to package the CryoFlex disposables devices Oct 12, 2020

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OCL. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201755
201861
201949
202037
202163
202259
202399
202459
202548
2026 (so far)42

Last 12 months by event type

  • Deaths2
  • Injuries15
  • Malfunctions27
  • Other or not stated1

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem17
  2. Obstruction of Flow13
  3. High impedance9
  4. Break6
  5. Separation Problem5
  6. Material Deformation3

In plain English: what the newest reports describe Written by AI

  • Several reports describe a continuous high-impedance alarm, meaning the device's electrical resistance check flagged a problem, so the ablation could not proceed. In each case the device was replaced and no patient effect was reported. One manufacturer analysis found no saline flow from the jaws of the returned device.

    5 reports: 2184009-2026-00964, 2184009-2026-00965, 2184009-2026-00968, 2184009-2026-00972, 2184009-2026-00976

  • Several reports describe a surgical clamp tip or branch breaking off during use or when the guide was pulled or disconnected; the device was replaced and no patient harm was reported. One report notes the fractured tip stayed attached to the guide and was retrieved.

    4 reports: 2182208-2026-62404, 2182208-2026-35949, 2182208-2026-20596, 2182208-2026-20615

  • In reports of the magnet cup, a small magnet part on the clamp jaw, detaching from the clamp during or after ablation, the cup was recovered in some cases and fell to the floor in another. No patient injury was reported, and the manufacturer filed these as possible malfunctions.

    3 reports: 3011706110-2026-00040, 3011706110-2026-00037, 3011706110-2026-00033

  • Several reports describe bleeding or a tear in the heart's upper chamber, the left atrium, during or after ablation. Repairs were made with sutures, and the manufacturers stated these were procedural complications rather than device malfunctions.

    3 reports: 3011706110-2026-00035, 3011706110-2026-00021, 3011706110-2026-00034

  • In one report, the clamp's irrigation, the saline flow used to cool the tissue, did not run properly when the clamp was closed during a test ablation. The clamp was replaced and no patient effect was reported.

    Report: 2182208-2026-48668

Written by AI from the narratives of the 20 newest reports that have one, received Apr 16, 2026 to Oct 29, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
93in the FDA’s Global Unique Device Identification Database
Establishment listings
97registered establishments that list this product code

Watch OCL in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OCL every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OCL. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.