Product codes

FDA product code

OAR: Injector, Vertebroplasty (Does Not Contain Cement) (FDA product code)

Follow OAR: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 888.4200
Review panel
Orthopedic
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
10 in the last 12 months
Median review time
63 daysthe latest 1 decisions
Recall records
260 in the last 12 months
Adverse event reports
20last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code OAR per year, by decision date, 1 since 2005. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K051820 PARALLAX EZFLOW CEMENT DELIVERY SYSTEMArthrocare Corp. Sep 6, 200563 days

Recalls

Recall records for product code OAR per year, by the date the recall began. Each recalled product is one record; these 26 records belong to 9 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20174
20180
20190
20202
20210
20220
20230
20242
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0073-2025Class II Merit Medical Systems, Inc.Inflation devices may have a small hole in the sterile barrier of the device and use of affected devices may result in exposure to pathogens/pyrogens which cou… Aug 19, 2024
Z-2260-2024Class II Stryker CorporationExpired Products distributed to customers Jun 3, 2024
Z-2067-2020Class II Merit Medical Systems, Inc.Vertebral hydraulic assemblies has incorrect expiration date printed on the labels.The product's shelf-life is two (2) years, but the expiration date printed o… Feb 13, 2020
Z-2068-2020Class II Merit Medical Systems, Inc.Vertebral hydraulic assemblies has incorrect expiration date printed on the labels.The product's shelf-life is two (2) years, but the expiration date printed o… Feb 13, 2020
Z-0352-2018Class II Medtronic Sofamor Danek USA IncMedtronic has discovered the directional arrow at the proximal end of the instrument may not correctly align with the cut out opening on the distal end of the… Dec 6, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code OAR. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201722
201811
201914
20205
202113
202211
202314
202417
202512
2026 (so far)19

Last 12 months by event type

  • Deaths0
  • Injuries5
  • Malfunctions15
  • Other or not stated0

Most reported device problems, last 12 months

  1. Fracture15
  2. Break2
  3. Difficult to Remove1
  4. Failure to Deliver1

In plain English: what the newest reports describe Written by AI

  • The cannula or needle broke while being removed from the spine, and a piece was left in the bone or pedicle. In some cases the case was stopped and the piece was removed later, and in others the provider judged removal unsafe and left it in place. Reports say the piece was seen on X-ray or CT, and the patient or family was told.

    9 reports: MW6001542, MW6001471, 3015967359-2026-00465, 3015967359-2026-00438, 3015967359-2026-00327, 3015967359-2026-00136, 24303673, 23777868, 3015967359-2026-00432

  • Fracture events are listed in manufacturer summary records. These summaries state no health consequences, but they give no details about how the fractures happened.

    5 reports: 3015967359-2026-99357, 3015967359-2026-99204, 3015967359-2026-99035, 3015967359-2025-99270, 3015967359-2025-99275

  • A spring came loose from the cannula handle and caught around the needle shaft, so the device could not be removed. The device then broke, leaving about 4 cm of needle in the pedicle. One report says anesthesia was prolonged by 1 to 1.5 hours, the procedure could not be completed, and the patient had more pain and spinal collapse.

    Report: 3015967359-2026-00432

  • One report says the blue handle broke away from the silver access cannula twice during a lumbar fusion procedure.

    Report: 24673360

  • One report says the surgeon saw cement in the spinal canal on imaging during surgery. The reporter believes the cement gun was pushed with too much pressure, and the patient had canal compression and was monitored. The manufacturer's note says the product did not malfunction during the case.

    Report: 3003272754-2026-00001

Written by AI from the narratives of the 16 newest reports that have one, received Oct 23, 2025 to Aug 26, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
185in the FDA’s Global Unique Device Identification Database
Establishment listings
72registered establishments that list this product code

Product codes classified under the same regulation.

Watch OAR in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get OAR every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in OAR. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.