Product codes

FDA product code

NVP: Holding Chambers, Direct Patient Interface (FDA product code)

Follow NVP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5630
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
160 in the last 12 months
Median review time
235 daysthe latest 16 decisions
Recall records
30 in the last 12 months
Adverse event reports
1last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code NVP per year, by decision date, 16 since 2005. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20180
20191
20200
20210
20221
20230
20240
20251
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K242667 AeroChamber2go Anti-Static Valved Holding ChamberTrudell Medical International Jan 15, 2025132 days
K210558 LiteAire Basic Dual-Valved, Collapsible MDI Holding ChamberThayer Medical Corporation Apr 1, 2022400 days
K181649 AeroChamber Plus* Flow-Vu* Anti-Static Valved Holding Chamber (VHC)Trudell Medical International Jan 11, 2019203 days
K160109 Thayer Medical LiteAire Dual-valved, Collapsible MDI Holding ChamberThayer Medical Corporation May 19, 2017486 days
K143615 Antistatic Compact Space ChamberMedical Developments International Limited Jan 26, 2016403 days
K140062 FSC ANTI-STATIC VALVED COLLAPSIBLE HOLDING CHAMBERFsc Laboratories, Inc. Oct 3, 2014266 days
K122252 SPACE CHAMBER PLUS COMPACT SPACE CHAMBER PLUSMedical Developments International Nov 13, 2013474 days
K130598 INSPIRACHAMBER ANTI-STATIC VALVED HOLDING CHAMBERInspirx, Inc. Jun 5, 201390 days
K112010 AEROCHAMBER PLUS FLOW-VU ANTI-STATIC VALVED HOLDING CHAMBER (VHC)Trudell Medical Intl. Jul 11, 2012363 days
K110293 OPTICHAMBER DIAMOND VALVED HOLDING CHAMBERRespironics New Jersey, Inc. Aug 9, 2011189 days

Recalls

Recall records for product code NVP per year, by the date the recall began. Each recalled product is one record; these 3 records belong to 2 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20212
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1932-2021Class II Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause i… Mar 16, 2021
Z-1941-2021Class II Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause i… Mar 16, 2021
Z-1995-2016Class II FSC Laboratories, IncProduct had torn/loose seal around the mouthpiece. May 16, 2016

Adverse event reports (MAUDE)

Medical device reports received per year that name product code NVP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20172
20183
20190
20200
20211
20222
20232
20243
20250
2026 (so far)1

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Detachment of Device or Device Component1
  2. Nonstandard Device1

In plain English: what the newest reports describe Written by AI

  • Parts of the valve inside the chamber broke loose and went into the patient's mouth or throat. In one report a piece lodged in the throat and blocked the airway until the patient cleared it by throwing themselves over a counter; the patient said they may have inhaled more deeply than usual.

    4 reports: 3005977696-2026-00001, 3005977696-2018-00001, 3005977696-2018-00002, 3005977696-2018-00003

  • Reports describe the valve tearing or breaking during use. One report said the patient washed the chamber with dishwashing detergent and air dried it, and the valve broke and dropped into the chamber body during the last use. The reports do not say whether washing caused the break.

    3 reports: 3005977696-2018-00003, 3005977696-2018-00002, 3005977696-2018-00001

  • A patient said the inside of their lips burned wherever they touched the mouthpiece. They feared an allergic reaction to the blue dye in the plastic, which could worsen their asthma. They said the problem started about twenty years ago and returns whenever they use the device. They had not received a clear answer from the manufacturer about the dye.

    Report: MW5112406

  • A caregiver reported that a child was admitted to hospital overnight after using a chamber with a small mask that was too small for the patient, so the patient did not receive the needed medication. The patient was discharged with a larger mask and the caregiver said the child was doing fine.

    Report: 9681154-2017-00020

  • A reporter said a pharmacist gave them a spacer for an inhaler when the prescription was for a nebulizer, and the pharmacist said it should work the same way. The reporter said the grandson's condition worsened because he did not get his medication as prescribed. The reporter corrected the problem.

    Report: MW5098695

Written by AI from the narratives of the 13 newest reports that have one, received Nov 23, 2017 to Feb 19, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
101in the FDA’s Global Unique Device Identification Database
Establishment listings
33registered establishments that list this product code

Product codes classified under the same regulation.

Watch NVP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get NVP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in NVP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.