Product codes

FDA product code

CAF: Nebulizer (Direct Patient Interface) (FDA product code)

Follow CAF: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 868.5630
Review panel
Anesthesiology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
5093 in the last 12 months
Median review time
236 daysthe latest 25 decisions
Recall records
360 in the last 12 months
Adverse event reports
713last 12 months, 4 deaths

510(k) and De Novo decisions

Decisions for product code CAF per year, by decision date, 509 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20178
20189
20193
20206
20218
20224
20238
20244
20257
2026 (so far)2

Latest decisions

NumberDevice and applicantDecision and review time
K254171 Mesh Nebulizer (UN204, UN205, UN209, UN210)Shenzhen Mericonn Technology Co., Ltd. Sep 18, 2026269 days
K260270 FindAir ONE for pMDI (FAO-MDI-V12-GRE-001)FindAir Sp. z o.o. Jun 2, 2026125 days
K251572 eRapid with eTrack SystemPari Respiratory Equipment, Inc. Dec 19, 2025211 days
K251659 Mesh Nebulizer (H6)Qingdao Future Medical Technology Co., Ltd. Nov 14, 2025168 days
K244035 Portable mesh nebulizer (JM821)Shenzhen Jermei Medical Device Technology Co., Ltd. Sep 19, 2025263 days
K243468 Compressor Nebulizer (NB-1100, NB-1101, NB-1102, NB-1103)Joytech Healthcare Co. , Ltd. Jul 2, 2025236 days
K250022 HeroTracker SenseVoluntis Jun 30, 2025178 days
K250583 AdheResp Smart Breath-actuated Mesh NebulizerHcmed Innovations Co., Ltd. Jun 20, 2025113 days
K242354 AllNEBEnchant Tek Co. , Ltd. Apr 29, 2025264 days
K233553 MiniSpacer® 1024, 1025, 1543 and 1024A, 1025A, 1543A Dual Spray MDI AdapterThayer Medical Corporation Jun 18, 2024225 days

Recalls

Recall records for product code CAF per year, by the date the recall began. Each recalled product is one record; these 36 records belong to 20 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
201714
20181
20190
20200
20211
20220
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-2514-2023Class I MEDLINE INDUSTRIES, LP - NorthfieldProduct dispositioned for scrap for sterility failure investigation that was inadvertently shipped to customers. Aug 4, 2023
Z-1516-2021Class II Smiths Medical ASD Inc.The firm became aware via complaints that one lot of ACE MDI Spacers with Small Masks and one lot of Palm Cups (Large) may have incorrect shipping box labels. Mar 31, 2021
Z-1058-2019Class II SANRAI INTERNATIONAL LLCThe product was designed for 120V usage and is being used in South Africa with 220V. There is a potential for the device to overheat and the mouthpiece can pop… Aug 29, 2018
Z-0710-2019Class I Medex Cardio-Pulmonary Inc., d.b.a. Smiths Medical CompanyLack of sterility assurance: leaking containers which could lead to exposure to infectious agents. Sep 5, 2017
Z-0711-2019Class I Medex Cardio-Pulmonary Inc., d.b.a. Smiths Medical CompanyLack of sterility assurance: leaking containers which could lead to exposure to infectious agents. Sep 5, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code CAF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
2017256
2018162
2019185
2020117
2021161
202255
2023107
2024102
2025194
2026 (so far)704

Last 12 months by event type

  • Deaths4
  • Injuries22
  • Malfunctions641
  • Other or not stated46

Most reported device problems, last 12 months

  1. Infusion or Flow Problem75
  2. Break52
  3. No Flow50
  4. Fluid/Blood Leak38
  5. Restricted Flow rate38
  6. Pressure Problem36

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
2,489in the FDA’s Global Unique Device Identification Database
Establishment listings
539registered establishments that list this product code

Product codes classified under the same regulation.

Watch CAF in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get CAF every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in CAF. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.