Product codes

FDA product code

LNS: Lithotriptor, Extracorporeal Shock-Wave, Urological (FDA product code)

Follow LNS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.5990
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
562 in the last 12 months
Median review time
166 daysthe latest 25 decisions
Recall records
10 in the last 12 months
Adverse event reports
30last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code LNS per year, by decision date, 56 since 2001. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20180
20190
20201
20211
20220
20232
20240
20251
2026 (so far)2

Latest decisions

NumberDevice and applicantDecision and review time
K261086 Break WaveSonomotion, Inc. Apr 29, 202628 days
K252913 Break WaveSonomotion, Inc. Jan 12, 2026122 days
K242922 Extracorporeal Shock Wave Lithotripter (U200)Shenzhen Wikkon Precision Technologies Co., Ltd. Jun 18, 2025267 days
K221903 Delta III ProDornier Medtech America, Inc. Feb 22, 2023237 days
K213772 LM-9300 Plus LithotripterLite-Med, Inc. Jan 19, 2023413 days
K201001 Modulith SLX-F2Karl Storz Endoscopy America Mar 30, 2021348 days
K201074 Delta III LithotripterDornier Medtech America, Inc. Sep 3, 2020134 days
K172084 Delta III LithotripterDornier Medtech America, Inc. Aug 8, 201729 days
K170122 Delta III LithotripterDornier Medtech America Jun 28, 2017166 days
K151298 Gemini XXP-HPDornier Medtech America Jul 30, 201576 days

Recalls

Recall records for product code LNS per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0265-2016Class II Siemens Medical Solutions USA, IncDisplay freeze of MODULARIS hand control results in information not being updated on the display. Current treatment data is not shown to the user. Sep 24, 2015

Adverse event reports (MAUDE)

Medical device reports received per year that name product code LNS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201754
201859
201960
202038
202155
202252
202386
202440
202561
2026 (so far)28

Last 12 months by event type

  • Deaths0
  • Injuries30
  • Malfunctions0
  • Other or not stated0

Most reported device problems, last 12 months

  1. Adverse Event Without Identified Device or Use Problem27
  2. Activation Failure1
  3. Difficult or Delayed Positioning1

In plain English: what the newest reports describe Written by AI

  • Patients reported bleeding into or around the kidney, called a hematoma (a pooled collection of blood), after shock wave treatment for kidney stones. Some reports describe minor cases where patients were kept in hospital briefly and then sent home.

    14 reports: 9613347-2026-00006, 9611388-2026-00011, 1037955-2026-00035, 9611388-2026-00009, 1037955-2026-00029, 9613347-2026-00005, 9611388-2026-00006, 9611388-2026-00007, 1037955-2026-00019, 9611388-2026-00005, 1037955-2026-00011, 9611388-2026-00004, 9613347-2026-00003, 9613347-2026-00002

  • Reports describe the spleen, an organ in the upper left abdomen, rupturing after a procedure that used the device. The narratives give few other details about the patients or the cause.

    4 reports: 9611388-2026-00010, 1037955-2026-00032, 9611388-2026-00008, 1037955-2026-00025

  • Two reports describe severe kidney bleeding after shock wave treatment. One patient had a 14 cm bleed under the kidney's outer covering and spent six days in intensive care; another needed surgical kidney removal (nephrectomy).

    2 reports: 9613347-2026-00002, 9613347-2026-00003

  • One report says a hand control unit, the part used to position the device and release the shock, malfunctioned. The manufacturer's field engineer replaced it, and the report says the positioning problem could have contributed to a patient's hematoma.

    Report: 1037955-2026-00035

  • One report describes a patient who developed severe, chronic skin damage after a shock wave therapy treatment. The report says a dermatologist has been unable to treat the damage.

    Report: MW5187612

Written by AI from the narratives of the 19 newest reports that have one, received Mar 12, 2026 to Oct 19, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
131in the FDA’s Global Unique Device Identification Database
Establishment listings
48registered establishments that list this product code

Watch LNS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get LNS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in LNS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.