Product codes

FDA product code

IMP: Cushion, Wheelchair (FDA product code)

Follow IMP: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 890.3920
Review panel
Physical Medicine
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
20 in the last 12 months
Median review time
16 daysthe latest 2 decisions
Recall records
10 in the last 12 months
Adverse event reports
34last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code IMP per year, by decision date, 2 since 1987. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K890653 ULTIMA WHEELCHAIR CUSHIONClark Pillow Co., Inc. Feb 28, 198920 days
K871006 EDCOOL AND EDCOOL JR. INSTANT COLD PACKAdvantage Credit Services, Inc. Mar 25, 198712 days

Recalls

Recall records for product code IMP per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1266-2014Class II Bock,Otto,Orthopedic Ind,IncOtto Bock is recalling all Aerial and Aerial Active Wheelchair Cushions from specific material numbers. During internal testing, it was discovered that there i… Jan 31, 2014

Adverse event reports (MAUDE)

Medical device reports received per year that name product code IMP. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20170
20182
20195
20206
20215
202211
202324
20247
20255
2026 (so far)34

Last 12 months by event type

  • Deaths0
  • Injuries3
  • Malfunctions29
  • Other or not stated2

Most reported device problems, last 12 months

  1. Material Deformation8
  2. Lack of Effect7
  3. Material Split, Cut or Torn6
  4. Inadequacy of Device Shape and/or Size3
  5. Crack2
  6. Material Too Soft/Flexible2

In plain English: what the newest reports describe Written by AI

  • Foam or cushion bases reportedly flattened, collapsed in the centre, or became uneven, bumpy, or misshapen. Some cushions would not regain their shape after being left overnight. One dealer requested a warranty replacement.

    8 reports: 9616084-2025-00070, 9616084-2024-00061, 1417592-2026-39481, 1417592-2026-58485, 1417592-2026-50318, 1417592-2026-34828, 1417592-2026-45838, 1417592-2026-53696

  • Reports describe cushions sliding or slipping out of place on the wheelchair, and one describes a user falling after a slick cushion shifted. Reporters say the non-slip rubber base did not hold the cushion and that there were no straps or other fastenings.

    4 reports: MW6002414, MW6000816, 1417592-2026-29344, 3005905321-2025-00004

  • Air-filled cushions reportedly lost air. One report traced the problem to a missing valve, and others pointed to a loose valve or a leaking seal. A dealer tightened a valve and the leak appeared to stop, but no final check was recorded.

    4 reports: 3008630266-2025-00001, 9616084-2025-00089, 3008630266-2025-00002, 1417592-2026-34503

  • Users reportedly developed skin breakdown or pressure sores. In one case, foam split under the user and the gel folded over, creating high-pressure areas that caused wounds on the thighs. In another, a sore healed after a cushion swap but returned after the user tried the same product again.

    3 reports: 9615350-2026-00004, 9615350-2026-00002, 1531186-2026-00011

  • Two reports say the cushion had no labelling, so the materials could not be checked. One of these reports also says a cushion was plain rather than the gel type expected, and was smaller than expected.

    2 reports: MW6002414, 1417592-2026-39593

Written by AI from the narratives of the 20 newest reports that have one, received Oct 24, 2024 to Oct 12, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
5,952in the FDA’s Global Unique Device Identification Database
Establishment listings
174registered establishments that list this product code

Watch IMP in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get IMP every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in IMP. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.