FDA product code
GFF: Bur, Surgical, General & Plastic Surgery (FDA product code)
Classification on the FDA’s site Total product life cycle report
- Device class
- Class I
- Regulation
- 21 CFR 878.4820
- Review panel
- General and Plastic Surgery
- Premarket route
- 510(k) exempt
- Implant
- No
- Life-sustaining or supporting
- No
- GMP exempt
- No
- Third-party review
- Not eligible
- Summary malfunction reporting
- Eligible
- 510(k) and De Novo decisions
- 160 in the last 12 months
- Median review time
- 21 daysthe latest 16 decisions
- Recall records
- 130 in the last 12 months
- Adverse event reports
- 97last 12 months, 0 deaths
510(k) and De Novo decisions
Decisions for product code GFF per year, by decision date, 16 since 1982. Review time is the days from receipt to decision.
Show the numbers
| Year | Decisions |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 0 |
| 2020 | 0 |
| 2021 | 0 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest decisions
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K974025 | ANSPACH SHIELDED ATTACHMENTThe Anspach Effort, Inc. | Jul 6, 1998256 days |
| K950449 | SURGICAL BURTransidyne General Corp. | Mar 1, 199526 days |
| K943758 | SURGICAL BURKomet Medical | Aug 22, 199420 days |
| K934583 | BURRSAmerican Medical Specialties, Inc. | Jan 26, 1994125 days |
| K894438 | MICRO-AIRE CUTTERS FOR MIDAS-REX INSTRUMENTSMicro-Aire Surgical Instruments, Inc. | Aug 21, 198935 days |
| K890090 | DANEK IRRIGATING BURR (DIB) SETDanek Medical, Inc. | Jan 24, 198914 days |
| K883255 | KOMET SURGICAL BURKomet Medical, Div. of Brasseler USA I, L.P. | Sep 15, 198844 days |
| K880859 | SURGICAL BURSNew England Surgical Instrument Corp. | Mar 21, 198820 days |
| K880706 | SURGICAL BURSNuell Air Equipment & Hospital Supplies, Inc. | Feb 26, 19884 days |
| K872475 | SURGICAL BURTava Surgical Instruments | Jul 2, 19879 days |
Recalls
Recall records for product code GFF per year, by the date the recall began. Each recalled product is one record; these 13 records belong to 13 recall events.
Show the numbers
| Year | Recall records |
|---|---|
| 2017 | 0 |
| 2018 | 0 |
| 2019 | 2 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 0 |
| 2023 | 0 |
| 2024 | 0 |
| 2025 | 0 |
| 2026 (so far) | 0 |
Latest recalls
| Recall and class | Firm and reason | Began |
|---|---|---|
| Z-1283-2021Class II | In2Bones, SASThis Field Action is being conducted following identification of manufacturing non-conformity of some batches of Shannon burrs diameter 2.0mm length 20mm, poss… | Feb 9, 2021 |
| Z-0591-2020Class II | Brasseler USA I LpOne lot of 3.5 mm twist drills were incorrectly laser etched as 2.5 mm the shaft of the device. | Oct 18, 2019 |
| Z-1206-2019Class II | Arthrex, Inc.Devices may generate excessive heat during use. | Jan 14, 2019 |
| Z-0568-2020Class II | Wright Medical Technology, Inc.The firm discovered a lack of adequate documentation confirming sterility on certain products. | Nov 8, 2016 |
| Z-1940-2017Class II | The Anspach Effort, Inc.Supplied Directions for Use (DFU) did not contain a recommended service interval. | Oct 6, 2016 |
Adverse event reports (MAUDE)
Medical device reports received per year that name product code GFF. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.
Show the numbers
| Year | Reports |
|---|---|
| 2017 | 83 |
| 2018 | 83 |
| 2019 | 80 |
| 2020 | 23 |
| 2021 | 76 |
| 2022 | 68 |
| 2023 | 96 |
| 2024 | 124 |
| 2025 | 72 |
| 2026 (so far) | 93 |
Last 12 months by event type
- Deaths0
- Injuries1
- Malfunctions95
- Other or not stated1
Most reported device problems, last 12 months
- Material Fragmentation26
- Break19
- Fracture10
- Material Twisted/Bent7
- Use of Device Problem6
- Device Contaminated During Manufacture or Shipping4
In plain English: what the newest reports describe Written by AI
Metal debris, shavings or dust came off the device while it cut or shaved bone or tissue in joint surgeries. The reports say the debris was removed from the patient's joint, and they state no harm to the patient.
4 reports: 1220246-2026-05347, 1220246-2026-04569, 1220246-2026-02982, 1220246-2026-03812
Burs and tips broke or fractured during use. Where stated, all pieces were accounted for, and one report says no fragments reached the patient, though it also mentions a broken anchor, so the details are unclear.
4 reports: 1017294-2026-00127, 25664623, 50754939, 3015967359-2026-99363
Burs were bent or damaged. Two reports say a bur would not work when torque was applied, one says the tip cover was bent, and one says the device was damaged where the blade meets the handle. Reports say the device was replaced during the case; one raised concern about possible tiny shavings in the patient, though none were seen.
4 reports: 1220246-2026-02788, 1220246-2026-02747, MW6002874, 1220246-2026-04728
Plastic parts came loose or peeled from the device. In one report a plastic sheath wrapped around the shaft, and in another plastic insulation detached inside a patient and was retrieved. A third report describes plastic peeling with no patient effect.
3 reports: 1220246-2026-04981, 1220246-2026-02803, 1220246-2026-03709
Small plastic pieces or an unidentified particle were found inside the sterile packaging of blades in three reports. One report says the package had been opened and the parts were behind the blade; no patient effect is stated.
3 reports: 0002936485-2026-00500, 0002936485-2026-00450, 0002936485-2026-00404
Written by AI from the narratives of the 20 newest reports that have one, received May 8, 2026 to Oct 23, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.
On the market
How widely the product code is used in FDA’s device identifier and establishment listing databases.
- Device identifiers (UDI)
- 5,795in the FDA’s Global Unique Device Identification Database
- Establishment listings
- 197registered establishments that list this product code
Other codes under 21 CFR 878.4820
Product codes classified under the same regulation.
Watch GFF in DeviceVigil
DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.
Get GFF every Monday
One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in GFF. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/classification · search product_code:GFFRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GFFRetrieved Nov 29, 2026, 4:33 PM UTC. FDA data updated Nov 16, 2026.
- device/510k · search product_code:GFF · count decision_dateRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 16, 2026.
- device/recall · search product_code:GFFRetrieved Nov 29, 2026, 4:33 PM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GFF · count event_date_initiatedRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 26, 2026.
- device/recall · search product_code:GFF · count res_event_numberRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 26, 2026.
- device/enforcement · search recall_number:("Z-1283-2021" "Z-0591-2020" "Z-1206-2019" "Z-0568-2020" "Z-1940-2017")Retrieved Nov 29, 2026, 4:33 PM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GFF AND date_received:[20251129 TO 20261129] · count event_type.exactRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GFF AND date_received:[20251129 TO 20261129] · count product_problems.exactRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 18, 2026.
- device/event · search device.device_report_product_code:GFF AND date_received:[20170101 TO 20261129] · count date_receivedRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 18, 2026.
- device/udi · search product_codes.code:GFFRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 2, 2026.
- device/registrationlisting · search products.product_code:GFFRetrieved Nov 29, 2026, 8:28 AM UTC. FDA data updated Nov 16, 2026.
- device/classification · search regulation_number:878.4820Retrieved Nov 28, 2026, 7:57 PM UTC. FDA data updated Nov 16, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil