Product codes

FDA product code

FFG: Device, Urine Flow Rate Measuring, Non-Electrical, Disposable (FDA product code)

Follow FFG: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.1800
Review panel
Gastroenterology and Urology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
170 in the last 12 months
Median review time
78 daysthe latest 17 decisions
Recall records
10 in the last 12 months
Adverse event reports
10last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FFG per year, by decision date, 17 since 1977. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20170
20180
20190
20200
20210
20220
20230
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K893827 PEAK FLOW RATE METERLaytech Medical Co. Aug 11, 198979 days
K883274 SURGITEK (R) UROFLOW SYSTEMMedical Engineering Corp. Feb 8, 1989189 days
K850169 ERIS URO-DIAGNOSTIC SYSTEMEris Medical Technology Apr 22, 198596 days
K844338 1URO-LOG HOME DIAGNOSTIC PACKEpcom Medical Systems, Inc. Feb 25, 1985109 days
K843442 URINARY DRAINAGE CONTAINER 2013 WITHVital Metrics, Inc. Jan 3, 1985121 days
K843441 URINARY DRAINAGE CONTAINER 2012-WITHVital Metrics, Inc. Jan 3, 1985121 days
K844030 ACCUMETER ELECTRONIC URINEMETER SYSTEMTravenol Laboratories, S.A. Nov 20, 198436 days
K843224 UROPUMP MODEL 1711Life-Tech Intl., Inc. Oct 19, 198464 days
K833043 UROMETERBrowne Medical, Inc. Feb 4, 1984151 days
K813641 VITAL METRICS URINE MONITORING SYSTEMVital Metrics, Inc. Mar 1, 198261 days

Recalls

Recall records for product code FFG per year, by the date the recall began. Each recalled product is one record; these 1 records belong to 1 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-1047-2024Class I Cardinal Health 200, LLCConvenience kits were manufactured and distributed with components which were subsequently recalled by Nurse Assist. Dec 4, 2023

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FFG. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201734
20189
201910
202092
2021109
202221
20236
20243
20253
2026 (so far)10

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions10
  • Other or not stated0

Most reported device problems, last 12 months

  1. Fluid/Blood Leak7
  2. Crack1
  3. Disconnection1
  4. Fitting Problem1
  5. Leak/Splash1
  6. Material Puncture/Hole1

In plain English: what the newest reports describe Written by AI

  • The urine bag, chamber or the join between tube and bag leaked or split in four reports. Two described leaks at a connection or seam, and two described a cracked chamber or a torn bag, which caused complete leakage.

    4 reports: 1417592-2026-61427, 1417592-2026-59861, 1417592-2024-00020, 1417592-2023-00440

  • Urine flowed slowly or not at all into the meter chamber in three reports. One report said nurses had to lift the tubing to drain it, and the bladder could not be emptied at times. Another said urine stayed in the drain, and a third said urine residue on the tube kept it from passing into the chamber, so it could not be measured.

    3 reports: 3007966929-2023-00001, 3007966929-2022-00033, 3007966929-2022-00016

  • The sample port, the small part used to draw urine samples, came off the meter in two reports. In one, it detached during an intra-abdominal pressure measurement. In the other, it came off when a nurse drew a sample with a syringe.

    2 reports: 1417592-2025-00165, 1417592-2024-00648

  • In one report, the catheter came out during placement even though the balloon, which holds the catheter in the bladder, was inflated. The patient reported burning when the balloon was inflated, and the area around the balloon looked torn. The reporter was not sure whether the cause was the device or the patient's anatomy.

    Report: 9612030-2023-03691

  • In one report, the catheter was found completely disconnected from the urine bag when a patient arrived from the recovery room. The reporter believed the catheter's small size did not fit properly into the bag's connector.

    Report: 1417592-2026-44561

Written by AI from the narratives of the 13 newest reports that have one, received Oct 28, 2022 to Oct 20, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
33in the FDA’s Global Unique Device Identification Database
Establishment listings
37registered establishments that list this product code

Product codes classified under the same regulation.

Watch FFG in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FFG every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FFG. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.