Product codes

FDA product code

EXS: Urinometer, Electrical (FDA product code)

Follow EXS: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.1800
Review panel
Gastroenterology and Urology
Premarket route
510(k) exempt
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Not eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
00 in the last 12 months
Median review time
Not availablethe latest 0 decisions
Recall records
60 in the last 12 months
Adverse event reports
3last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code EXS per year, by decision date. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

No decisions on record for this product code.

Recalls

Recall records for product code EXS per year, by the date the recall began. Each recalled product is one record; these 6 records belong to 6 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20173
20180
20190
20200
20210
20221
20231
20240
20250
2026 (so far)0

Latest recalls

Recall and classFirm and reasonBegan
Z-0554-2024Class II C.R. Bard IncBD (C.R. Bard) has received user complaints reporting that when the device was connected to WiFi/Internet, the time displayed on the Sensica device changed dur… Nov 15, 2023
Z-1293-2022Class II C.R. Bard IncComplaints relating to urine output measurement accuracy. May 19, 2022
Z-0565-2018Class II C.R. Bard, Inc.BMD has identified that some lots of CritiCore(R) monitors may experience failures involving urine output volume measurement fluctuations, core bladder tempera… Nov 10, 2017
Z-2243-2018Class II C.R. Bard, Inc.Issues identified with the monitor including urine output measurement errors, temperature measurement errors and undesired alarms. Nov 10, 2017
Z-0488-2018Class II C.R. Bard, Inc.The possibility exists that use of the Uros Automated Urine Output and Temperature Monitor may lead to the loss of urine output measurement data and/or urine o… Sep 29, 2017

Adverse event reports (MAUDE)

Medical device reports received per year that name product code EXS. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201729
201816
201918
202013
202133
2022226
202397
202413
202516
2026 (so far)3

Last 12 months by event type

  • Deaths0
  • Injuries0
  • Malfunctions3
  • Other or not stated0

Most reported device problems, last 12 months

  1. Volume Accuracy Problem2
  2. Device Handling Problem1
  3. Failure to Sense1

In plain English: what the newest reports describe Written by AI

  • Several reports describe the hourly display freezing or grouping output wrongly. Output from several hours appears under one hour, or the hour label stays stuck on an earlier time, so nurses cannot see what was produced each hour. In one report the nurse averaged output by hand; a restart often fixed it, and the device sometimes lost earlier data.

    4 reports: 1018233-2025-06929, 1018233-2025-04890, 1018233-2025-04949, 1018233-2025-04466

  • Several reports describe the device restarting or rebooting during use. In one report the restart was linked to a damaged load cell, the internal part that weighs the collected urine.

    3 reports: 1018233-2025-04195, 1018233-2025-03031, 1018233-2025-01431

  • Some reports describe the device's internal control module or screen failing. One report says the screen stayed dark while the power light was on, and another says the control module could not pass a calibration step during a software upgrade and needed replacement.

    2 reports: 1018233-2025-07049, 1018233-2025-07722

  • Reports describe parts of the connection between the device and the drainage bag failing. One report says a plastic cap came off and the bag was hung too high, causing urine to flow backward. Another says the tube sensor could not detect the catheter tubing. The manufacturer agreed to replace broken units free of charge in one case.

    2 reports: 1018233-2026-00435, 1018233-2025-03508

  • A report describes the device being unable to hold power on battery. The biomedical staff found it stayed on only about 10 minutes after unplugging, not the full 60 minutes expected.

    Report: 1018233-2025-04814

Written by AI from the narratives of the 19 newest reports that have one, received Dec 13, 2024 to Jul 9, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
17in the FDA’s Global Unique Device Identification Database
Establishment listings
8registered establishments that list this product code

Product codes classified under the same regulation.

Watch EXS in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get EXS every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EXS. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.