Product codes

FDA product code

FEO: Lithotriptor, Ultrasonic (FDA product code)

Follow FEO: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class II
Regulation
21 CFR 876.4480
Review panel
Gastroenterology and Urology
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
140 in the last 12 months
Median review time
99 daysthe latest 14 decisions
Recall records
71 in the last 12 months
Adverse event reports
311last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code FEO per year, by decision date, 14 since 1984. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20171
20184
20190
20200
20210
20220
20231
20240
20250
2026 (so far)0

Latest decisions

NumberDevice and applicantDecision and review time
K230893 Swiss LthoClast TrilogyE.M.S Electro Medical Systems S.A Oct 23, 2023206 days
K182490 Swiss LithoClast TrilogyE.M.S Electro Medical Systems S.A Oct 9, 201828 days
K181997 Swiss LithoClast TrilogyE.M.S Electro Medical Systems S.A Aug 30, 201835 days
K181364 Swiss LithoClast TrilogyE.M.S Electro Medical Systems S.A Jun 20, 201828 days
K173234 Swiss LithoClast TrilogyE.M.S Electro Medical Systems S.A Jan 10, 201897 days
K171024 ShockPulse-SE Lithotripsy SystemCybersonics, Inc. Aug 21, 2017138 days
K142428 Shock Pulse-SE Lithotripsy System CYBERWAND IICybersonics, Inc. Nov 13, 201476 days
K993046 FIBRA SONICS ULTRASONIC LITHOTRIPTOR LITHOSONIC, MODEL LS-2000Fibra Sonics, Inc. Nov 22, 199973 days
K973251 KSEA CALCUSONKARL STORZ Endoscopy-America, Inc. Jun 22, 1998297 days
K920235 ULTRASOUND GENERATOR MODLE 2270Richard Wolf Medical Instruments Corp. Dec 7, 1992325 days

Recalls

Recall records for product code FEO per year, by the date the recall began. Each recalled product is one record; these 7 records belong to 5 recall events.

All of them in the FDA’s recall database

Recall records per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearRecall records
20170
20180
20190
20201
20210
20221
20230
20240
20254
2026 (so far)1

Latest recalls

Recall and classFirm and reasonBegan
Z-1494-2026Class II Olympus Corporation of the AmericasMis-wired component-the improperly wired component can result in additional noise on the power supply output. Noise on the ultrasonic input circuit is not cons… Jan 8, 2026
Z-1477-2026Class II Olympus Corporation of the AmericasOngoing investigations identified additional instances of the device Generator remaining in a blinking phase waiting to recognize the transducer. Damage to the… Nov 14, 2025
Z-1478-2026Class II Olympus Corporation of the AmericasOngoing investigations identified additional instances of the device Generator remaining in a blinking phase waiting to recognize the transducer. Damage to the… Nov 14, 2025
Z-1479-2026Class II Olympus Corporation of the AmericasOngoing investigations identified additional instances of the device Generator remaining in a blinking phase waiting to recognize the transducer. Damage to the… Nov 14, 2025
Z-0452-2026Class II Olympus Corporation of the AmericasThe device may either fail to start up, or the transducer may start briefly and then stop, accompanied by an error light on the generator. In addition, the bod… Oct 8, 2025

Adverse event reports (MAUDE)

Medical device reports received per year that name product code FEO. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
20178
20189
201912
2020128
202166
202230
202339
2024221
2025356
2026 (so far)286

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions309
  • Other or not stated1

Most reported device problems, last 12 months

  1. Break46
  2. Communication or Transmission Problem33
  3. No Device Output28
  4. Activation Problem21
  5. Output Problem19
  6. Activation Failure16

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
98in the FDA’s Global Unique Device Identification Database
Establishment listings
47registered establishments that list this product code

Product codes classified under the same regulation.

Watch FEO in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get FEO every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in FEO. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.