Product codes

FDA product code

EKX: Handpiece, Direct Drive, Ac-Powered (FDA product code)

Follow EKX: new clearances and recalls, emailed on Mondays

Free. We email a confirmation link first; every email has a one-click unsubscribe. Privacy

Device class
Class I
Regulation
21 CFR 872.4200
Review panel
Dental
Premarket route
510(k)
Implant
No
Life-sustaining or supporting
No
GMP exempt
No
Third-party review
Eligible
Summary malfunction reporting
Eligible
510(k) and De Novo decisions
901 in the last 12 months
Median review time
247 daysthe latest 25 decisions
Recall records
00 in the last 12 months
Adverse event reports
27last 12 months, 0 deaths

510(k) and De Novo decisions

Decisions for product code EKX per year, by decision date, 90 since 1976. Review time is the days from receipt to decision.

All of them in the FDA’s 510(k) database

510(k) and De Novo decisions per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearDecisions
20172
20183
20193
20201
20215
20223
20234
20244
20255
2026 (so far)1

Latest decisions

NumberDevice and applicantDecision and review time
K261987 Reusable SmartPegOsstell AB Sep 8, 202688 days
K252223 Alpha Endo Handpiece (Alpha Endo)SHENZHEN SUPERLINE TECHNOLOGY CO., LTD. Oct 16, 202592 days
K251597 InnerView SystemPerimetrics, Inc. Sep 18, 2025114 days
K243692 EnDrive (EnDriveUS)Advanced Technology Research (A.T.R.) S.R.L. Aug 22, 2025266 days
K242514 Endo Motor (E-LITE MAX, E-LITE PRO, E-LITE INO)Shenzhen Rogin Medical Co., Ltd. Apr 24, 2025244 days
K241065 ChecQ (AC100)Dentis Co., Ltd. Mar 21, 2025337 days
K243911 HPR Cordless Hygiene HandpieceHandpiece Headquarters Dec 20, 20241 day
K222688 The TrustGenoss Co., Ltd. Aug 9, 2024703 days
K233865 X-Smart Pro; X-Smart Pro+Dentsply Sirona, Inc. Jul 24, 2024231 days
K232551 EM-07 Cordless Endo MotorForum Engineering Technologies (96) , Ltd. Jul 9, 2024321 days

Recalls

Recall records for product code EKX per year, by the date the recall began. Each recalled product is one record.

All of them in the FDA’s recall database

No recalls on record for this product code.

Adverse event reports (MAUDE)

Medical device reports received per year that name product code EKX. Reports aren’t validated, not every event is reported, and a count of reports isn’t an event rate.

Where did MAUDE go?

Adverse event reports received per year, 2017 to 2026. 2026 is the year so far.
Show the numbers
YearReports
201710
201849
201956
202067
202179
202237
202314
202419
20259
2026 (so far)27

Last 12 months by event type

  • Deaths0
  • Injuries1
  • Malfunctions26
  • Other or not stated0

Most reported device problems, last 12 months

  1. Mechanical Problem11
  2. Incorrect Measurement8
  3. Device Handling Problem4
  4. Incorrect, Inadequate or Imprecise Result or Readings3
  5. Break1
  6. Circuit Failure1

In plain English: what the newest reports describe Written by AI

  • Several reports say the device gave wrong or poor length or measurement readings. In one, the length indicator jumped into the red zone just after the instrument entered the tooth. The reports do not state a cause.

    8 reports: 9614977-2026-00132, 9614977-2026-00133, 9614977-2026-00136, 9614977-2026-00121, 9614977-2026-00122, 9614977-2026-00176, 9614977-2026-00174, 9614977-2026-00157

  • Several reports say the device stopped working during use, would not rotate, or lost power intermittently. One says it stopped while inside the patient's root canal. Some reports state no injury, and others say the outcome is unknown.

    4 reports: 8031010-2026-00583, 9611053-2026-01189, 2320721-2026-00081, 2320721-2026-00013

  • Two reports say a file broke off inside the root canal while the handpiece was stuck. One says the broken piece stayed in the patient's tooth. The other reports no patient injury.

    2 reports: 9614977-2026-00173, 8031010-2026-00579

  • One report says the handpiece's button switched on and off without being pressed.

    Report: 9614977-2026-00371

  • One report says the handpiece overheated and the patient had cramps. No injury resulted, and the patient outcome is unknown while more information is requested.

    Report: 9614977-2026-00157

Written by AI from the narratives of the 19 newest reports that have one, received Feb 18, 2026 to Sep 28, 2026. Reports aren’t validated, not every event is reported, and a summary can be wrong: read the reports before you rely on it.

On the market

How widely the product code is used in FDA’s device identifier and establishment listing databases.

Device identifiers (UDI)
773in the FDA’s Global Unique Device Identification Database
Establishment listings
148registered establishments that list this product code

Watch EKX in DeviceVigil

DeviceVigil is a Chrome and Edge extension that shows this page’s numbers beside the FDA’s own 510(k), classification and recall pages, lists the individual adverse event reports, and tells you when something changes for the product codes you watch.

Add to Chrome — free See how it works

Get EKX every Monday

One short email after openFDA’s weekly update with that week’s 510(k), De Novo and PMA decisions and recalls in EKX. Free. Add up to two more codes, separated by commas.

Up to three codes. We email a confirmation link first; every brief has a one-click unsubscribe. Privacy

Sources

Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.

DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.