FDA device news · Product code HRS
FDA 510(k) clearance
SALGINA 2.5mm Distal Radius System (K261351): Bonebridge AG 510(k) clearance
Zug, CH
- Decision
- Substantially Equivalent
- Decision date
- Jun 26, 2026
- Received
- Apr 24, 2026
- 510(k) type
- Traditional
- Product code
- HRSPlate, Fixation, Bone
- Review panel
- Orthopedic
- Device class
- Class II
- Regulation
- 21 CFR 888.3030
- Third-party review
- No
- Summary or statement
- Summary
- Review time
- 63 daysreceipt to decision, calendar days
- Median in HRS
- 83 daysthe latest 24 other decisions
- HRS decisions
- 60in the last 12 months
- Applicant’s 510(k)s
- 10in openFDA, this one included
In plain English Written by AI
What the company’s 510(k) summary says about the device, its predicate and its testing, in plain words.
- What it is
- The SALGINA 2.5mm Distal Radius System is a bone fixation plate system, a metal plate and screws used to hold broken bone in position while it heals. It is a variant of the Bonebridge Osteosynthesis Plating System. The plates are mainly stainless steel with pure titanium inlay clips, the screws are stainless steel, and the surgical instruments are stainless steel, PEEK, EPDM or silicone.
- What it’s cleared for
- The device is indicated for treating intra-articular fractures of the distal radius (breaks at the wrist end of the forearm bone that extend into the joint surface), extra-articular fractures of the distal radius (breaks at the same site that do not extend into the joint), and fractures with associated radial shaft fractures.
- Compared with (the predicate)
- How it differs
- The summary says the device has the same intended use, similar indications, the same design features, the same range of physical dimensions and the same materials as the predicate devices, and that it is compatible with screws from the primary predicate.
- Testing the summary lists
- Sterilization validation (gamma irradiation per ISO 11137-2 and steam sterilization per ISO 17664 and ISO 17665-1)
- Sterile packaging validation (ISO 11607, ASTM F1980, ISTA 2A transport simulation, and related package tests)
- Biocompatibility (ISO 10993 series and toxicological risk assessment)
- Mechanical testing (static and dynamic comparison with predicate devices, including four-point bending)
- MRI safety (displacement, torque and heating tests per ASTM F2052, F2213 and F2182, and image artifact testing per ASTM F2119)
Written by AI from the 510(k) summary the company filed with the FDA (the PDF), and checked against it: predicate numbers and figures must appear in the summary. A summary is the company’s own account, not the FDA’s review, and the AI can still get it wrong: read the PDF before you rely on it.
How the review time compares
Calendar days from the day FDA received the 510(k) to its decision. They include time the submission waited on the company for answers, so they run longer than FDA’s 90-day review goal.
K261351 took 63 calendar days from receipt to decision. Of the latest 24 other decisions in product code HRS, 16 took longer, 8 were faster; their median was 83 days.
Latest decisions in HRS
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K262939 | HERO Sternal Closure SystemHero Orthopedics, LLC · Traditional | Nov 2, 202673 days |
| K263602 | Arthrex Plates, Screws and Pins, and WashersArthrex, Inc. · Special | Oct 29, 202629 days |
| K261135 | Trochlear Salvage Plating SystemSkeletal Dynamics, Inc. · Traditional | Oct 26, 2026202 days |
| K262779 | ANTHEM™ Fracture SystemGlobus Medical, Inc. · Traditional | Oct 23, 202679 days |
| K263407 | Tempo Plating SystemPace Surgical · Special | Oct 23, 202628 days |
| K263269 | Park's Pectus SystemTdm Co., Ltd. · Special | Oct 15, 202627 days |
| K261611 | TDM Large Bone Plate and Screw SystemTdm Co., Ltd. · Special | Oct 2, 2026140 days |
| K262649 | Alians ForearmNewclip Technics · Traditional | Sep 28, 202660 days |
| K261892 | ProRib Fixation SystemCosta Surgical, Inc. · Traditional | Sep 23, 2026110 days |
| K262098 | EnHAnce PEEK Bunion SystemNvision Biomedical Technologies · Special | Sep 18, 202688 days |
Other 510(k)s from Bonebridge AG
The applicant’s other clearances in openFDA, newest first. Company names are matched as the FDA recorded them, so a renamed or differently spelled company may not appear.
| Number | Device and applicant | Decision and review time |
|---|---|---|
| K260228 | POYA 3.5mm Medial Proximal Tibia SystemBonebridge AG · Traditional | Apr 24, 202688 days |
| K252191 | BRUSIO Trauma Toolbox System; TAMINA 3.5mm Proximal Humerus SystemBonebridge AG · Traditional | Dec 17, 2025156 days |
| K250933 | LORRAINE 2.5/3.5mm Distal Humerus SystemBonebridge AG · Traditional | Jun 11, 202575 days |
| K243308 | Bonebridge Osteosynthesis Plating System (SALGINA 2.5mm Distal Radius System, CASCELLA 3.5mm Superior Clavicle System, LEPORELLO 3.5mm Olecranon Syste)Bonebridge AG · Traditional | Dec 20, 202460 days |
| K242399 | Bonebridge Osteosynthesis Plating SystemBonebridge AG · Traditional | Oct 31, 202479 days |
| K240318 | SITTER 3.5mm Versatile SystemBonebridge AG · Traditional | Aug 23, 2024203 days |
| K231292 | TAMINA 3.5mm Proximal Humerus System; POYA 3.5MM Lateral Proximal Tibia System; LORRAINE 3.5mm Distal Humerus SystemBonebridge AG · Traditional | Jul 19, 202376 days |
| K213864 | Bonebridge Osteosynthesis Plating SystemBonebridge AG · Traditional | Sep 2, 2022266 days |
| K203002 | SALGINA 2.5mm Volar Distal Radius System, CASCELLA 3.5mm Superior Clavicle System, TAMlNA 3.5mm Proximal Humerus System, TRIFT 3.5mm 1/3 Tubular SystemBonebridge AG · Traditional | Oct 5, 2021369 days |
Watch HRS in DeviceVigil
DeviceVigil is a free Chrome and Edge extension. Watch the product codes and companies you follow, and it tells you about new clearances, recalls and MAUDE reports for them, right beside the FDA’s own pages.
Get HRS every Monday
One short email after openFDA’s weekly update with that week’s new 510(k)s, De Novos, PMAs and recalls in HRS. Free. Add up to two more codes, separated by commas.
Sources
Every figure on this page comes from openFDA, the FDA’s public data service, which notes that its data is not validated. Check the FDA record before you rely on a figure.
- device/510k · search k_number:K261351Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:HRSRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/classification · search product_code:HRSRetrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search product_code:HRS AND decision_date:[20251129 TO 20261129]Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
- device/510k · search applicant:"Bonebridge AG"Retrieved Nov 22, 2026, 9:07 PM UTC. FDA data updated Nov 18, 2026.
DeviceVigil is an independent tool by Thump LLC and is not affiliated with or endorsed by the FDA. This page isn’t medical, legal or regulatory advice.
DeviceVigil